Javascript must be enabled to continue!
Electron cyclotron resonance plasma excitation in a toroidal plasma
View through CrossRef
In this article, Electron Cyclotron Resonance (ECR) absorption, Upper-Hybrid Resonance (UHR) absorption and Electron Bernstein Wave (EBW) conversion are systematically confirmed in magnetically confined KT-5D plasma which is sole-excited by a magnetron source. A 2.45 GHz ECR system has been developed on the toroidal helimak KT-5D to produce and sustain a steady-state plasma. 0.98 kW electron cyclotron wave produced by the magnetron is injected into the vacuum chamber through rectangular waveguides with a power absorption efficiency of 40∼50%. A steady-state plasma is excited with a density of several 1016/m3 and electron temperature of up to 30 eV. The radial profile of plasma density shows that ECR absorption dominates the power deposition with a higher hydrogen pressure of at the order of 10-1 Pa, while UHR absorption dominates with a lower hydrogen pressure of at the order of 10-2 Pa. Plasma density in the discharge with a superimposed magnetic shear has demonstrated the wave conversion from ECR to EBW.
AIP Publishing
Title: Electron cyclotron resonance plasma excitation in a toroidal plasma
Description:
In this article, Electron Cyclotron Resonance (ECR) absorption, Upper-Hybrid Resonance (UHR) absorption and Electron Bernstein Wave (EBW) conversion are systematically confirmed in magnetically confined KT-5D plasma which is sole-excited by a magnetron source.
A 2.
45 GHz ECR system has been developed on the toroidal helimak KT-5D to produce and sustain a steady-state plasma.
0.
98 kW electron cyclotron wave produced by the magnetron is injected into the vacuum chamber through rectangular waveguides with a power absorption efficiency of 40∼50%.
A steady-state plasma is excited with a density of several 1016/m3 and electron temperature of up to 30 eV.
The radial profile of plasma density shows that ECR absorption dominates the power deposition with a higher hydrogen pressure of at the order of 10-1 Pa, while UHR absorption dominates with a lower hydrogen pressure of at the order of 10-2 Pa.
Plasma density in the discharge with a superimposed magnetic shear has demonstrated the wave conversion from ECR to EBW.
Related Results
Effects of an external toroidal field on the rotating field driven current in a Rotamak for fusion plasma confinement
Effects of an external toroidal field on the rotating field driven current in a Rotamak for fusion plasma confinement
The mechanism which creates toroidal currents in Tokamaks to magnetically confine hot fusion plasmas is cyclic and subjects the components to large periodic stresses. An alternativ...
Comparative Analysis of Conventional and Toroidal Propeller through CFD Methods
Comparative Analysis of Conventional and Toroidal Propeller through CFD Methods
Toroidal propeller comprising circular blades is gaining significant attention due to higher efficiency; lower noise levels and other advantages compared to the current propeller m...
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
(English) Spacecraft entering planetary atmospheres are enveloped by a plasma layer with high levels of ionization, caused by the extreme temperatures in the shock layer. The charg...
Shedding Frequency and Motion of Jujube Fruits in Various Excitation Modes
Shedding Frequency and Motion of Jujube Fruits in Various Excitation Modes
HighlightsThe motion responses of fruits varied greatly in different excitation modes.The excitation modes included horizontal, vertical, and rotational.The shedding frequency of f...
The Nuclear Fusion Award
The Nuclear Fusion Award
The Nuclear Fusion Award ceremony for 2009 and 2010 award winners was held during the 23rd IAEA Fusion Energy Conference in Daejeon. This time, both 2009 and 2010 award winners w...
Spontaneous Appearance of Toroidal Field in Field Reversed Configuration Plasma
Spontaneous Appearance of Toroidal Field in Field Reversed Configuration Plasma
The field reversed configuration (FRC) plasma had been thought to have poloidal field only, but in this experiment, toroidal field was observed. We report magnetic probe measuremen...
Plasmonic Toroidal Dipolar Response under Radially Polarized Excitation
Plasmonic Toroidal Dipolar Response under Radially Polarized Excitation
AbstractPlasmonic toroidal resonance has attracted growing interests because of its low loss electromagnetic properties and potential high sensitive nanophotonic applications. Howe...
Toroidal Dipolar Excitation in Metamaterials Consisting of Metal nanodisks and a Dielectrc Spacer on Metal Substrate
Toroidal Dipolar Excitation in Metamaterials Consisting of Metal nanodisks and a Dielectrc Spacer on Metal Substrate
AbstractWe have investigated numerically toroidal dipolar excitation at optical frequency in metamaterials whose unit cell consists of three identical Ag nanodisks and a SiO2spacer...

