Analysis of Voltage Dip Impact on Doubly Fed Induction Generator under Dynamic Conditions
View through CrossRef
Doubly Fed Induction Generator (DFIG) is the most widely employed generator in the Wind Energy Conversion Systems (WECS) for the production of electricity. However, despite all of its various advantages, it is extremely vulnerable to grid faults such as voltage dip since its stator is directly coupled to the grid. A voltage dip problem is one the main issues among the power quality concerns. This fault causes the flow of excessive current across both the stator and the rotor terminals, which may lead to serious damage to the generator, power converters, and DC Link capacitor. On the other hand, the current Grid Codes (GC) requires the system to stay connected to the grid during this fault condition and support it in healing its nominal voltage. This capacity of the system is known as the Low Voltage Ride Through (LVRT) capacity. For the system to achieve such capacity, appropriate protection mechanisms or controlling strategies must be utilized. Therefore, in this paper, the crowbar protection technique, PI controller, and the Adaptive Neuro-Fuzzy Inference System (ANFIS) controller are employed. Furthermore, the performance of the system employing PI, crowbar, and ANFIS is analyzed and compared under grid fault conditions, i.e., a voltage dip with a magnitude of 0.1 pu (worst case) using MATLAB/Simulink software and based on actual data obtained from Adama II wind farm. The obtained results unveil that the settling time of ANFIS for controlling the rotor currents in d and q axes (idr and iqr) and DC link voltage is 3.6 s, 3.57 s, and 3.4 s, respectively. On the other hand, the settling times of the PI controller for controlling the rotor currents in d and q axes and the DC link voltage are found to be 4 s, 3.91 s, and 45.2 s, respectively, while the crowbar protection technique’s settling times are found to be 4 s, 6 s, and 4.9 s, respectively. It is evident from the aforesaid results that the ANFIS controller provides the best performance of the three strategies since it allows both the rotor currents and the DC link voltage to return to their steady state values faster than the other two techniques, employed in this investigation.
Title: Analysis of Voltage Dip Impact on Doubly Fed Induction Generator under Dynamic Conditions
Description:
Doubly Fed Induction Generator (DFIG) is the most widely employed generator in the Wind Energy Conversion Systems (WECS) for the production of electricity.
However, despite all of its various advantages, it is extremely vulnerable to grid faults such as voltage dip since its stator is directly coupled to the grid.
A voltage dip problem is one the main issues among the power quality concerns.
This fault causes the flow of excessive current across both the stator and the rotor terminals, which may lead to serious damage to the generator, power converters, and DC Link capacitor.
On the other hand, the current Grid Codes (GC) requires the system to stay connected to the grid during this fault condition and support it in healing its nominal voltage.
This capacity of the system is known as the Low Voltage Ride Through (LVRT) capacity.
For the system to achieve such capacity, appropriate protection mechanisms or controlling strategies must be utilized.
Therefore, in this paper, the crowbar protection technique, PI controller, and the Adaptive Neuro-Fuzzy Inference System (ANFIS) controller are employed.
Furthermore, the performance of the system employing PI, crowbar, and ANFIS is analyzed and compared under grid fault conditions, i.
e.
, a voltage dip with a magnitude of 0.
1 pu (worst case) using MATLAB/Simulink software and based on actual data obtained from Adama II wind farm.
The obtained results unveil that the settling time of ANFIS for controlling the rotor currents in d and q axes (idr and iqr) and DC link voltage is 3.
6 s, 3.
57 s, and 3.
4 s, respectively.
On the other hand, the settling times of the PI controller for controlling the rotor currents in d and q axes and the DC link voltage are found to be 4 s, 3.
91 s, and 45.
2 s, respectively, while the crowbar protection technique’s settling times are found to be 4 s, 6 s, and 4.
9 s, respectively.
It is evident from the aforesaid results that the ANFIS controller provides the best performance of the three strategies since it allows both the rotor currents and the DC link voltage to return to their steady state values faster than the other two techniques, employed in this investigation.
Related Results
Stability Modeling and Analysis of Grid Connected Doubly Fed Wind Energy Generation Based on Small Signal Model
Stability Modeling and Analysis of Grid Connected Doubly Fed Wind Energy Generation Based on Small Signal Model
Stable wind power generation can ensure the quality of power transmitted by the grid. The application of large-scale grid-connected wind power systems will induce problems such as ...
Effects of Voltage Sags on the Doubly Fed induction Generator using PI Controllers
Effects of Voltage Sags on the Doubly Fed induction Generator using PI Controllers
The paper presents dynamic and transient behaviour of the Doubly Fed Induction Generator (DFIG) in the wind farms. When Voltage sag or any faults occurs in the network, the variabl...
Steady State Modeling and Performance Analysis of a Wind Turbine-Based Doubly Fed Induction Generator System with Rotor Control
Steady State Modeling and Performance Analysis of a Wind Turbine-Based Doubly Fed Induction Generator System with Rotor Control
The utilization of renewable energy sources aids in the economic development of a country. Among the various renewable energy sources, wind energy is more effective for electricity...
Advanced data processing of ATF claddings
Advanced data processing of ATF claddings
Digital image processing (DIP), neural networks, and artificial intelligence (AI) are
revolutionizing materials science, enabling precise and efficient analysis of microscopic feat...
Outcomes Following Allogeneic Stem Cell Transplantation for AML in First Completion Remission Are Comparable between MRD Negative Patients and MRD Positive Patients Receiving Induction Only and Are Superior to MRD Positive Patients Receiving Induction and
Outcomes Following Allogeneic Stem Cell Transplantation for AML in First Completion Remission Are Comparable between MRD Negative Patients and MRD Positive Patients Receiving Induction Only and Are Superior to MRD Positive Patients Receiving Induction and
Background:
Data suggests that the presence of measurable residual disease (MRD) at the time of transplant for AML portends a poor prognosis. The timing of MRD asses...
Drugs associated with DIP
Drugs associated with DIP
Drug-induced parkinsonism (DIP) is one of the most frequent extrapyramidal disorders that develops against the background of prescribing a large number of medications. Initially, D...
The voltage dip and doubly fed induction generator with considering uncertainty conditions
The voltage dip and doubly fed induction generator with considering uncertainty conditions
The paper presents the transient behavior of the doubly fed induction generator (DFIG) in the wind turbine (WT) in the normal and voltage dip condition. When voltage dip occurs in ...
Fasting Reduces Elevated Hippocampal pAkt-S473 and pGSK3 β -S9 but not
ptau-S396 in Male Obese Zucker Rats (OZRs) With No Effect in Lean Zucker
Rats (LZRs) or Female Zucker Rats
Fasting Reduces Elevated Hippocampal pAkt-S473 and pGSK3 β -S9 but not
ptau-S396 in Male Obese Zucker Rats (OZRs) With No Effect in Lean Zucker
Rats (LZRs) or Female Zucker Rats
Altered phosphorylation in the PI3K/Akt/GSK3β insulin signaling pathway
in the hippocampus contributes to increased phosphorylated tau (ptau) and
...