Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Effects of Voltage Sags on the Doubly Fed induction Generator using PI Controllers

View through CrossRef
The paper presents dynamic and transient behaviour of the Doubly Fed Induction Generator (DFIG) in the wind farms. When Voltage sag or any faults occurs in the network, the variables in the doubly Fed Induction Generators are varying severely. If the voltage sag occurs, Active and Reactive power that generated by the DFIG will decrease and will increase respectively, The DC voltage link will be bigger, and the rotor current will increase. The DFIG in the wind farms uses Proportional Integral controller for controlling of electronic devices (Rotor Side Converter and Grid Side Converter). Even though the model of Doubly Fed Induction Generators and electronic device in the paper are linear, The Proportional Integral controllers cannot protect and control the variables. So, the power electronic converters and the DC-link can damage due to over voltages and over currents. Doubly Fed Induction Generator in the wind farm is simulated in MATLAB software. The results of the simulation present over voltage and over current in the DC-link and in the rotor of the Doubly Fed Induction Generator. In addition, it will explore the effect of Proportional Integral controller in Doubly Fed Induction Generator when three-phase short circuit fault occurs
Title: Effects of Voltage Sags on the Doubly Fed induction Generator using PI Controllers
Description:
The paper presents dynamic and transient behaviour of the Doubly Fed Induction Generator (DFIG) in the wind farms.
When Voltage sag or any faults occurs in the network, the variables in the doubly Fed Induction Generators are varying severely.
If the voltage sag occurs, Active and Reactive power that generated by the DFIG will decrease and will increase respectively, The DC voltage link will be bigger, and the rotor current will increase.
The DFIG in the wind farms uses Proportional Integral controller for controlling of electronic devices (Rotor Side Converter and Grid Side Converter).
Even though the model of Doubly Fed Induction Generators and electronic device in the paper are linear, The Proportional Integral controllers cannot protect and control the variables.
So, the power electronic converters and the DC-link can damage due to over voltages and over currents.
Doubly Fed Induction Generator in the wind farm is simulated in MATLAB software.
The results of the simulation present over voltage and over current in the DC-link and in the rotor of the Doubly Fed Induction Generator.
In addition, it will explore the effect of Proportional Integral controller in Doubly Fed Induction Generator when three-phase short circuit fault occurs.

Related Results

Stability Modeling and Analysis of Grid Connected Doubly Fed Wind Energy Generation Based on Small Signal Model
Stability Modeling and Analysis of Grid Connected Doubly Fed Wind Energy Generation Based on Small Signal Model
Stable wind power generation can ensure the quality of power transmitted by the grid. The application of large-scale grid-connected wind power systems will induce problems such as ...
Assessment and Mitigation Studies of Voltage Sags during Sympathetic Inrush Current
Assessment and Mitigation Studies of Voltage Sags during Sympathetic Inrush Current
The system voltage may be negatively impacted by the transformer’s energisation which draws a large value of magnetising inrush current for a few seconds. During the transformer’s ...
Steady State Modeling and Performance Analysis of a Wind Turbine-Based Doubly Fed Induction Generator System with Rotor Control
Steady State Modeling and Performance Analysis of a Wind Turbine-Based Doubly Fed Induction Generator System with Rotor Control
The utilization of renewable energy sources aids in the economic development of a country. Among the various renewable energy sources, wind energy is more effective for electricity...
Evaluation of DVR and SSFCL in Mitigating Voltage Sags and Interruptions in Power Distribution Network
Evaluation of DVR and SSFCL in Mitigating Voltage Sags and Interruptions in Power Distribution Network
This study investigates the performance of Dynamic Voltage Restorers (DVRs) and Solid-State Fault Current Limiters (SSFCLs) through simulations, addressing the problem of voltage s...
Impacts of voltage sags and protection coordination on sensitive equipment in distribution systems
Impacts of voltage sags and protection coordination on sensitive equipment in distribution systems
Nowadays, a lot of sensitive electronic equipment is widely used in modern power systems such as power converters and adjustable speed drivers. Voltage sag has gained more interest...
Analysis of Voltage Dip Impact on Doubly Fed Induction Generator under Dynamic Conditions
Analysis of Voltage Dip Impact on Doubly Fed Induction Generator under Dynamic Conditions
Doubly Fed Induction Generator (DFIG) is the most widely employed generator in the Wind Energy Conversion Systems (WECS) for the production of electricity. However, despite all of ...

Back to Top