Javascript must be enabled to continue!
DEVELOPMENT OF PORTABLE SYSTEM FOR MUSCLE TWITCH EXPERIMENT MEASUREMENT OF MUSCLE CONTRACTION TIME
View through CrossRef
The muscle contraction time of fish can be the good index for swimming capability to estimate the maximum swimming speed, by defining the maximum tail beating performance. The muscle contraction time of jack mackerel, Thachurus japonicus (18.0 – 19.4 cm of fork length (FL), n = 15) was measured with newly developed portable systemand compared with the conventional setup with the electric stimulation pulse from generator and battery system.The muscle contraction profile was not different among each measurementeven with the different pulse pattern of electric stimulation between portable and conventional setup. The shortest recording of muscle contraction time with the portable system was 22.6 ± 2.1 ms, not different to the conventional system as 24.3 ± 1.9 ms with the generator and 24.2 ± 2.0 mswith the battery system. Time duration and the pulse pattern of the electric stimulus do not affect the muscle contraction time. The portable system can be used to measure the muscle contraction time of fish for the field experiment and onboard the fishing boat without alternating current (AC) electricity supply. Keywords: Muscle contraction time, jack mackerel, portable system, electric stimulus, muscle twitch experiment.
Title: DEVELOPMENT OF PORTABLE SYSTEM FOR MUSCLE TWITCH EXPERIMENT MEASUREMENT OF MUSCLE CONTRACTION TIME
Description:
The muscle contraction time of fish can be the good index for swimming capability to estimate the maximum swimming speed, by defining the maximum tail beating performance.
The muscle contraction time of jack mackerel, Thachurus japonicus (18.
0 – 19.
4 cm of fork length (FL), n = 15) was measured with newly developed portable systemand compared with the conventional setup with the electric stimulation pulse from generator and battery system.
The muscle contraction profile was not different among each measurementeven with the different pulse pattern of electric stimulation between portable and conventional setup.
The shortest recording of muscle contraction time with the portable system was 22.
6 ± 2.
1 ms, not different to the conventional system as 24.
3 ± 1.
9 ms with the generator and 24.
2 ± 2.
0 mswith the battery system.
Time duration and the pulse pattern of the electric stimulus do not affect the muscle contraction time.
The portable system can be used to measure the muscle contraction time of fish for the field experiment and onboard the fishing boat without alternating current (AC) electricity supply.
Keywords: Muscle contraction time, jack mackerel, portable system, electric stimulus, muscle twitch experiment.
.
Related Results
Sternomastoid muscle twitch maximum relaxation rate: prolonged slowing with fatigue and post-tetanic acceleration
Sternomastoid muscle twitch maximum relaxation rate: prolonged slowing with fatigue and post-tetanic acceleration
1. The maximum rate of relaxation of stimulated twitches (twitch maximum relaxation rate) of the sternomastoid muscle was compared with its frequency-force curve (expressed as the ...
Anesthesia (12)
Anesthesia (12)
A deltoid motor response is a satisfactory endpoint for successful block. (Columbia Presbyterian Medical Center, New York, NY) Reg Anesth Pain Med 2000;25:356–359.This study invest...
Uncovering the potential of Twitch as a source for social media metrics
Uncovering the potential of Twitch as a source for social media metrics
The social live streaming service Twitch was launched in 2008 as Justin.tv, rebranded as Twitch Interactive in 2011, and acquired by Amazon in 2014. Although launched originally as...
Poster 247: Muscle ERRγ Overexpression Mitigates the Muscle Atrophy after ACL injury
Poster 247: Muscle ERRγ Overexpression Mitigates the Muscle Atrophy after ACL injury
Objectives:
Anterior cruciate ligament (ACL) reconstruction is the 6th most common orthopedic procedure performed in the United States (1,2). There is substanti...
The temperature sensitivity of motor units in rat soleus
The temperature sensitivity of motor units in rat soleus
AbstractTemperature has a significant impact on the performance of the neuromuscular system and motor control processes. The smallest functional components of these systems are mot...
Paxilline Prevents the Onset of Myotonic Stiffness in Pharmacologically Induced Myotonia: A Preclinical Investigation
Paxilline Prevents the Onset of Myotonic Stiffness in Pharmacologically Induced Myotonia: A Preclinical Investigation
Reduced Cl− conductance causes inhibited muscle relaxation after forceful voluntary contraction due to muscle membrane hyperexcitability. This represents the pathomechanism of myot...
BLEEDING PURPLE, SEEING PINK: DOMESTIC VISIBILITY, GENDER & SOCIAL REPRODUCTION IN THE HOME STUDIOS OF TWITCH.TV
BLEEDING PURPLE, SEEING PINK: DOMESTIC VISIBILITY, GENDER & SOCIAL REPRODUCTION IN THE HOME STUDIOS OF TWITCH.TV
From greenscreens in the bedroom to webcams on refrigerators, household surfaces underlie the broadcast of personality on Twitch.tv, Amazon’s $15 billion platform for live video en...
Comparison of Twitch Contractile Properties of Plantar Flexor Muscles in 9–10-Year-Old Girls and Boys
Comparison of Twitch Contractile Properties of Plantar Flexor Muscles in 9–10-Year-Old Girls and Boys
Twitch contractile properties of plantar flexor muscles were compared in 9- to 10-year-old girls and boys. No significant gender differences (p > .05) in isometric maximal volun...

