The Development of Hybrid Cooling Photovoltaic Panel by using Active and Passive Cooling System

View through CrossRef
Photovoltaic (PV) panel are crucial in the conversion of solar irradiance into electrical energy. However, the efficiency of PV panel is indirectly influenced by the surface temperature of the panels. According to typical PV module standards, the effect of panel temperature on efficiency is -0.47 %/°C, which indicates that a rise of 1°C reduces the PV panel's efficiency by 0.47 %. The efficiency of the PV panel achieves its maximum value when the panel temperature reaches 25 ℃, which is the standard test condition (STC). Moreover, a high working temperature can also reduce the lifetime of the PV panel. Based on the limitations that have been highlighted above, this project aims to design and develop a hybrid cooling PV panel by using active and passive cooling system with Arduino UNO R3. In this project, 100 W monocrystalline photovoltaic panel has been selected to analyze the result before and after installation of hybrid cooling system. Active cooling system is a water sprinkler system which is applied in front of the PV panel. Meanwhile, the passive cooling system is a combination of hydrogel beads and the heat-sink cooling system which will be installed behind the PV panel. In result, the average power output of PV panel without cooling was 30.59 W while the average power output of PV panel with hybrid cooling was 34.66 W. Moreover, the average power increased due to cooling was 13.31 %. In a nutshell, the proposed project has the ability to develop a hybrid cooling system to improve the performance and efficiency of the PV panel in order to increase the power output of the panel.
Title: The Development of Hybrid Cooling Photovoltaic Panel by using Active and Passive Cooling System
Description:
Photovoltaic (PV) panel are crucial in the conversion of solar irradiance into electrical energy.
However, the efficiency of PV panel is indirectly influenced by the surface temperature of the panels.
According to typical PV module standards, the effect of panel temperature on efficiency is -0.
47 %/°C, which indicates that a rise of 1°C reduces the PV panel's efficiency by 0.
47 %.
The efficiency of the PV panel achieves its maximum value when the panel temperature reaches 25 ℃, which is the standard test condition (STC).
Moreover, a high working temperature can also reduce the lifetime of the PV panel.
Based on the limitations that have been highlighted above, this project aims to design and develop a hybrid cooling PV panel by using active and passive cooling system with Arduino UNO R3.
In this project, 100 W monocrystalline photovoltaic panel has been selected to analyze the result before and after installation of hybrid cooling system.
Active cooling system is a water sprinkler system which is applied in front of the PV panel.
Meanwhile, the passive cooling system is a combination of hydrogel beads and the heat-sink cooling system which will be installed behind the PV panel.
In result, the average power output of PV panel without cooling was 30.
59 W while the average power output of PV panel with hybrid cooling was 34.
66 W.
Moreover, the average power increased due to cooling was 13.
31 %.
In a nutshell, the proposed project has the ability to develop a hybrid cooling system to improve the performance and efficiency of the PV panel in order to increase the power output of the panel.

Related Results

Performance investigation of photovoltaic modules by back surface water cooling
Performance investigation of photovoltaic modules by back surface water cooling
The temperature of the photovoltaic module has an adverse effect on the performance of photovoltaic modules. The photovoltaic module converts a small portion of energy from solar r...
Quantitative Research on China’s PV Industry Policy based on PMC-index Model
Quantitative Research on China’s PV Industry Policy based on PMC-index Model
Photovoltaic industry is an important new energy industry, and photovoltaic industry policy is an important part of the photovoltaic industry. To analyze the structure and evolutio...
A Brief Review on Radiant Cooling Panel with Different Chilled Water Pipe Configurations
A Brief Review on Radiant Cooling Panel with Different Chilled Water Pipe Configurations
Radiant cooling systems are commonly applied in commercial applications because of their energy-saving potential. This potential can be further enhanced by evaluating the cooling p...
Diathesis Markings in Haloban Language: A Linguistic Typological Study
Diathesis Markings in Haloban Language: A Linguistic Typological Study
This research aims to explore, analyze, and explain the Haloban language's linguistic phenomena, including morphological typology and argument structure. This research also seeks t...
Studi Eksperimental Performa Photovoltaic Cell dengan Variasi Jenis Pendingin
Studi Eksperimental Performa Photovoltaic Cell dengan Variasi Jenis Pendingin
Energi matahari salah satu sumber energi yang dapat dikonversikan menjadi energi listrik melalui photovoltaic cell. Salah satu tujuan dari penelitian ini adalah mengetahui performa...
The Performance Evaluation of Photovoltaic Integrated Organic Phase Change Material in a Single Container using Indoor Solar Simulator
The Performance Evaluation of Photovoltaic Integrated Organic Phase Change Material in a Single Container using Indoor Solar Simulator
Photovoltaic panels convert sunlight, a renewable energy source, into electrical energy. The abundant irradiance will heat the photovoltaic panel, reducing the panel's efficiency. ...