Javascript must be enabled to continue!
Comparative estimation of toric intraocular lenses optic power calculation acurary
View through CrossRef
Purpose. To assess the refractive error of toric IOL calculation using Holladay IOL Consultant program with Holladay II formula, Verion navigation system using Holladay II and Barrett formulas. Methods. A retrospective analysis of the records of patients who underwent phacoemulsification with Acrysof IQ Toric (Alcon, USA) IOL implantation was carried out in IRTC Eye Microsurgery Ekaterinburg Center. The IOL was calculated using Holladay IOL Consultant program with Holladay II formula and Verion navigation system with the Holladay II and Barrett formulas. Results. Average refractive error of calculating IOL optical power on Verion diagnostic system using Holladay II formula was 0.20±0.83 diopters, using Barrett formula 0.26±0.76 diopters. IOL optic power calculation using Hicsoap Professional software using Holladay II formula showed refractive error of 0.07±0.76 diopters. Conclusions. The best result for refractive error was demonstrated by Holladay IOL Consultant Professional calculator (Holladay II formula). The difference in errors using Holladay II and Barrett formulas in Verion navigation system turned out to be insignificant. The best refractive result was demonstrated in correction of straight astigmatism by toric IOL implantation. Key words: IOL optical power calculation; toric IOL; IOL calculation formulas.
Title: Comparative estimation of toric intraocular lenses optic power calculation acurary
Description:
Purpose.
To assess the refractive error of toric IOL calculation using Holladay IOL Consultant program with Holladay II formula, Verion navigation system using Holladay II and Barrett formulas.
Methods.
A retrospective analysis of the records of patients who underwent phacoemulsification with Acrysof IQ Toric (Alcon, USA) IOL implantation was carried out in IRTC Eye Microsurgery Ekaterinburg Center.
The IOL was calculated using Holladay IOL Consultant program with Holladay II formula and Verion navigation system with the Holladay II and Barrett formulas.
Results.
Average refractive error of calculating IOL optical power on Verion diagnostic system using Holladay II formula was 0.
20±0.
83 diopters, using Barrett formula 0.
26±0.
76 diopters.
IOL optic power calculation using Hicsoap Professional software using Holladay II formula showed refractive error of 0.
07±0.
76 diopters.
Conclusions.
The best result for refractive error was demonstrated by Holladay IOL Consultant Professional calculator (Holladay II formula).
The difference in errors using Holladay II and Barrett formulas in Verion navigation system turned out to be insignificant.
The best refractive result was demonstrated in correction of straight astigmatism by toric IOL implantation.
Key words: IOL optical power calculation; toric IOL; IOL calculation formulas.
Related Results
Comparison of Toric Intraocular Lens Calculations Between the IOLMaster 700 and Pentacam AXL
Comparison of Toric Intraocular Lens Calculations Between the IOLMaster 700 and Pentacam AXL
Purpose: To compare toric IOL (Intra Ocular Lenses) suggestions for power, toric, and IOL alignment between the IOLMaster 700 and Pentacam AXL (Axial Length).
Methods: This single-...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Intraocular lens models: Ecological distribution footprint and usage trends at a large ophthalmology centre
Intraocular lens models: Ecological distribution footprint and usage trends at a large ophthalmology centre
Abstract
Background
Operating theatres significantly contribute to hospital’s environmental footprint, underscoring the need to evaluate the ecol...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Abstract
Purpose: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism. Methods: 31 eyes of 31 patien...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Abstract
Purpose: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism.
Methods: 31 eyes of 31 patie...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Abstract
Purpose: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism. Methods: 31 eyes of 31 patien...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity
Abstract
Background: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism. Methods: 31 eyes of 31 pat...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Abstract
Purpose: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism. Methods: 31 eyes of 31 patien...

