Javascript must be enabled to continue!
Theoretical exploration of low GWP refrigerant mixtures as replacement to HFC-134A in a vapour compression refrigeration system
View through CrossRef
Hydro-fluorocarbons (HFCs) that are not harmful to ozone layer and are used in many appli-cations, including as refrigerants, aerosols, solvents and blowing agents for insulating foams replace chlorofluorocarbons and hydro chlorofluorocarbons (HCFCs). However, some HFCs have a high GWP, which stands for “Global Warming Potential(GWP).” Because of the grow-ing concern over global climate change, researchers are paying closer attention for alternatives to these HFCs. The main focus of this work was on the theoretical analysis of the refrigerant mixtures namely AC5, R430A, and R440A as direct replacements for HFC-134a in a refriger-ator. The performance of the refrigerator may be enhanced using heat exchanger. The com-pressor discharge temperature, COP, VCC, refrigerant mass flow rate, power consumption of a compressor and pressure ratio were used to measure the performance of a home refrigerator. The typical COP of R440A and R430A was about 2.5% and 1.4% higher than that of HFC-134, while the average COP of AC5 was 6.1% lesser than that of HFC-134a. R430A almost has the same VCC (Volumetric Cooling Capacity) as HFC-134a. The results also show that HFC-134a uses more power than AC5, R440A, and R430A. R440A and AC5 have higher compressor outlet temperatures than HFC-134a, which affects the life span of the compressor. In com-parison with all the above refrigerants, R430A gives the best overall performance and used as replacement to HFC-134a in a VCR.
Title: Theoretical exploration of low GWP refrigerant mixtures as replacement to HFC-134A in a vapour compression refrigeration system
Description:
Hydro-fluorocarbons (HFCs) that are not harmful to ozone layer and are used in many appli-cations, including as refrigerants, aerosols, solvents and blowing agents for insulating foams replace chlorofluorocarbons and hydro chlorofluorocarbons (HCFCs).
However, some HFCs have a high GWP, which stands for “Global Warming Potential(GWP).
” Because of the grow-ing concern over global climate change, researchers are paying closer attention for alternatives to these HFCs.
The main focus of this work was on the theoretical analysis of the refrigerant mixtures namely AC5, R430A, and R440A as direct replacements for HFC-134a in a refriger-ator.
The performance of the refrigerator may be enhanced using heat exchanger.
The com-pressor discharge temperature, COP, VCC, refrigerant mass flow rate, power consumption of a compressor and pressure ratio were used to measure the performance of a home refrigerator.
The typical COP of R440A and R430A was about 2.
5% and 1.
4% higher than that of HFC-134, while the average COP of AC5 was 6.
1% lesser than that of HFC-134a.
R430A almost has the same VCC (Volumetric Cooling Capacity) as HFC-134a.
The results also show that HFC-134a uses more power than AC5, R440A, and R430A.
R440A and AC5 have higher compressor outlet temperatures than HFC-134a, which affects the life span of the compressor.
In com-parison with all the above refrigerants, R430A gives the best overall performance and used as replacement to HFC-134a in a VCR.
Related Results
Microstructural evolution and mechanical properties of in situ nano Ta4HfC5 reinforced SiBCN composite ceramics
Microstructural evolution and mechanical properties of in situ nano Ta4HfC5 reinforced SiBCN composite ceramics
Abstract
In this paper, the in situ nano Ta 4 HfC 5 reinforced SiBCN-Ta 4 HfC 5 composite ceramics were prepared by a combination of two-step mechanical alloying and reacti...
Analisis Chiller Dengan Menggunaan R123 Dan R134a Pada Kinerja Pendinginan
Analisis Chiller Dengan Menggunaan R123 Dan R134a Pada Kinerja Pendinginan
AbstrakChiller adalah mesin refrigerasi yang memiliki fungsi utama mendinginkan air pada sisi evaporator, air yang didinginkan selanjutnya didistribusi ke alat penukar kalor (FCU; ...
Air-Conditioning Using Waste Heat Energy
Air-Conditioning Using Waste Heat Energy
Abstract
All oil & gas building facilities such as control room, electrical room, substation and personal accommodation etc., require a comfortable indoor condit...
Komparasi Kinerja AC Kendaraan dengan Menggunakan Refrigeran R-134a, dan R-290
Komparasi Kinerja AC Kendaraan dengan Menggunakan Refrigeran R-134a, dan R-290
The development of vapor compression refrigeration systems currently depends on the issue of environmental problems related to ozone layer depletion (ODP) and global warming potent...
An Alternative Method for the Cooling of Power Microelectronics Using Classical Refrigeration
An Alternative Method for the Cooling of Power Microelectronics Using Classical Refrigeration
Classical refrigeration using vapor compression has been widely applied over the past decades to large-scale industrial systems, with few known applications to the microelectronic ...
An Alternative Method for the Cooling of Power Microelectronics Using Classical Refrigeration
An Alternative Method for the Cooling of Power Microelectronics Using Classical Refrigeration
Classical refrigeration using vapor compression has been widely applied over the last decades to large-scale industrial systems, with few known applications to the microelectronics...
Solar Powered Air-Conditioning Using Absorption Refrigeration Technique
Solar Powered Air-Conditioning Using Absorption Refrigeration Technique
The present work includes design, construction and operates of a prototype solar absorption refrigeration system, using methanol as a refrigerant to avoid any refrigerant that caus...
Application and Exploration of Carbon Dioxide R744 as Refrigerant and Secondary Refrigerant in Refrigerating Unit of Commercial Super
Application and Exploration of Carbon Dioxide R744 as Refrigerant and Secondary Refrigerant in Refrigerating Unit of Commercial Super
In this paper, the cascade refrigeration system and the load cooling system of the natural working medium are integrated as one unit system, which can meet the needs of different t...

