Improved Understanding of Stent Malapposition Using Virtual Bench Testing

View through CrossRef
Intravascular imaging techniques such as optical coherence tomography (OCT) and intravascular ultrasound (IVUS) are often used to assess strut apposition, but only provide limited insight into the three-dimensional appositioning behaviour of stents. Recently, a new approach has been introduced to study the phenomenon of incomplete stent apposition (ISA) based on finite element simulations. In this study, we employed this virtual strut apposition assessment technique in the setting of coronary bifurcation stenting and compared simulated strut–artery distances of two stent designs with actual measurements based on OCT imaging using a silicone model. Stenting of the main branch leads to malapposed struts in the proximal part and the average strut–artery distance in that region for the Integrity stent is 126 μm based on the simulation and 117±14 μm based on the OCT analysis. For the Multi-Link 8 stent, this average distance is 150 μm and 174±7 µm for the simulation and thein vitroOCT measurements respectively. In conclusion, the virtual assessment of strut appositioning results in similar strut–artery distances when compared with measurements based on OCT-visualisedin vitrostent deployments and could be used to optimise devices and procedures.
Title: Improved Understanding of Stent Malapposition Using Virtual Bench Testing
Description:
Intravascular imaging techniques such as optical coherence tomography (OCT) and intravascular ultrasound (IVUS) are often used to assess strut apposition, but only provide limited insight into the three-dimensional appositioning behaviour of stents.
Recently, a new approach has been introduced to study the phenomenon of incomplete stent apposition (ISA) based on finite element simulations.
In this study, we employed this virtual strut apposition assessment technique in the setting of coronary bifurcation stenting and compared simulated strut–artery distances of two stent designs with actual measurements based on OCT imaging using a silicone model.
Stenting of the main branch leads to malapposed struts in the proximal part and the average strut–artery distance in that region for the Integrity stent is 126 μm based on the simulation and 117±14 μm based on the OCT analysis.
For the Multi-Link 8 stent, this average distance is 150 μm and 174±7 µm for the simulation and thein vitroOCT measurements respectively.
In conclusion, the virtual assessment of strut appositioning results in similar strut–artery distances when compared with measurements based on OCT-visualisedin vitrostent deployments and could be used to optimise devices and procedures.

Related Results

Comparative outcome analysis of enterprise and neuroform stent-assisted coiling of cerebral aneurysms: A review of the literature
Comparative outcome analysis of enterprise and neuroform stent-assisted coiling of cerebral aneurysms: A review of the literature
Introduction: One of the popular treatment strategies for complex cerebral aneurysms with wide necks or low dome-to-neck ratios is stent-assisted coiling. The most widely used intr...
Value of stent boost imaging in decision making after coronary stenting
Value of stent boost imaging in decision making after coronary stenting
AbstractBackground: Several studies reported the comparability of digital stent enhancement techniques (including stent boost imaging) in detecting suboptimal results of coronary s...
Predictors of insistent restenosis in patients undergoing percutaneous intervention
Predictors of insistent restenosis in patients undergoing percutaneous intervention
Coronary artery disease is one of the leading causes of morbidity and mortality worldwide. The first percutaneous coronary intervention was performed by Andreas Gruntzig on Septemb...
Abstract 6025: Optimal Stent Deployment. Five Seconds Is Not Enough
Abstract 6025: Optimal Stent Deployment. Five Seconds Is Not Enough
Background . The risk of thrombosis which had been well described since the advent of stenting, is currently being re-addressed in the era of drug-eluting stents (DES)....
Long-term efficacy of stent placement for treating inferior vena cava stenosis following liver transplantation
Long-term efficacy of stent placement for treating inferior vena cava stenosis following liver transplantation
The aims of this study were to evaluate both the efficacy of stent placement for treating inferior vena cava (IVC) stenosis and the patency of hepatic veins (HVs) following IVC ste...