Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Radiographic Assessment of a Canine Uncemented Porous‐Coated Anatomic Total Hip Prosthesis

View through CrossRef
Thirty uncemented porous‐coated anatomic total hip prostheses in 24 dogs were evaluated radiographically at 6 months, 12 months, or 18 months after arthroplasty. All dogs were fully weight bearing and free of lameness at the time of follow‐up. Radiographs were assessed for prosthetic component alignment, percentage of femoral canal fill, resorptive and formative bony changes, and changes at the implant bone interface. No evidence of infection, loosening, or failure of component fixation was seen. Settling of the acetabular component and subsidence of the femoral stem was seen early after surgery. Cortical atrophy was seen in all femurs and was the most significant bony remodeling change. Early results of clinical and radiographic evaluation of uncemented total hip arthroplasty in dogs have been encouraging.
Title: Radiographic Assessment of a Canine Uncemented Porous‐Coated Anatomic Total Hip Prosthesis
Description:
Thirty uncemented porous‐coated anatomic total hip prostheses in 24 dogs were evaluated radiographically at 6 months, 12 months, or 18 months after arthroplasty.
All dogs were fully weight bearing and free of lameness at the time of follow‐up.
Radiographs were assessed for prosthetic component alignment, percentage of femoral canal fill, resorptive and formative bony changes, and changes at the implant bone interface.
No evidence of infection, loosening, or failure of component fixation was seen.
Settling of the acetabular component and subsidence of the femoral stem was seen early after surgery.
Cortical atrophy was seen in all femurs and was the most significant bony remodeling change.
Early results of clinical and radiographic evaluation of uncemented total hip arthroplasty in dogs have been encouraging.

Related Results

Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register Evaluation of 170,413 operations
Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register Evaluation of 170,413 operations
BACKGROUND AND PURPOSE: Since the introduction of total hip arthroplasty (THA) in Sweden, both components have most commonly been cemented. A decade ago the frequency of uncemented...
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
This paper explores South African hip-hop activist Emile YX?'s work to suggest that he presents an alternative take on mainstream US and South African hip-hop. While it is arguable...
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
Abstract Despite advancements in fracture prediction tools and osteoporosis management, hip fractures remain a significant consequence of bone fragility, with a 22% one...
Single‐Stage Revision Using an Uncemented, Porous‐Coated, Anatomic Endoprosthesis in Two Dogs
Single‐Stage Revision Using an Uncemented, Porous‐Coated, Anatomic Endoprosthesis in Two Dogs
Objective—To describe the clinical and radiographic features of septic and aseptic failure of two femoral endoprostheses and their successful revision.Study Design—Case report.Anim...
Abstract 1772: A naturally occurring canine model of peripheral T-cell lymphoma, not otherwise specified
Abstract 1772: A naturally occurring canine model of peripheral T-cell lymphoma, not otherwise specified
Abstract Despite being the most common subtype of human peripheral T-cell lymphoma (PTCL), PTCL-not otherwise specified (PTCL-NOS) remains a poorly understood diagno...
COMPARISON OF RADIATION DOSE FOR TWO DIGITAL RADIOGRAPHIC SYSTEM IN CORONARY ANGIOGRAPHY PROCEDURE
COMPARISON OF RADIATION DOSE FOR TWO DIGITAL RADIOGRAPHIC SYSTEM IN CORONARY ANGIOGRAPHY PROCEDURE
Objectives To evaluate the radiation dose to patients using flat-panel detector (FPD) and image intensifier charge-coupled device (II-CCD) digital radiographic sy...

Back to Top