Javascript must be enabled to continue!
U.S. Utility's Experience with Surveillance Dosimetry
View through CrossRef
Carolina Power & Light Company (CP&L) has completed a series of calculations and measurements for benchmarking the neutron flux in and outside the reactor vessel wall of the H. B. Robinson, Unit No. 2 (HBR2) reactor vessel. Transport calculations have been performed over the height of the core region and correlated with reactor cavity and internal surveillance capsule measurements. Corrections in the calculational approaches were found necessary. An additional improvement on determinations has been provided by ORNL's application of LEPRICON to the HBR2 dosimetry and vessel.
Having found cavity dosimetry measurements superior to those from internal dosimetry capsules at HBR2, CP &L has added the former in the cavities of its BWRs and is contemplating its use at the new Shearon Harris PWR.
ASTM International100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959
Title: U.S. Utility's Experience with Surveillance Dosimetry
Description:
Carolina Power & Light Company (CP&L) has completed a series of calculations and measurements for benchmarking the neutron flux in and outside the reactor vessel wall of the H.
B.
Robinson, Unit No.
2 (HBR2) reactor vessel.
Transport calculations have been performed over the height of the core region and correlated with reactor cavity and internal surveillance capsule measurements.
Corrections in the calculational approaches were found necessary.
An additional improvement on determinations has been provided by ORNL's application of LEPRICON to the HBR2 dosimetry and vessel.
Having found cavity dosimetry measurements superior to those from internal dosimetry capsules at HBR2, CP &L has added the former in the cavities of its BWRs and is contemplating its use at the new Shearon Harris PWR.
Related Results
Abstract PS05-06: Outcomes of Surveillance using Contrast Enhanced Mammography in Women with a Personal History of Breast Cancer
Abstract PS05-06: Outcomes of Surveillance using Contrast Enhanced Mammography in Women with a Personal History of Breast Cancer
Abstract
Background
Women with a personal history of breast cancer (PHBC) have a high rate of subsequent breast malignancy. Annual mammography with se...
Technologies for retrospective radiation dosimetry
Technologies for retrospective radiation dosimetry
Abstract
Radiation dosimetry is an important task for assessing the biological damages created in human being due to ionising radiation exposure. Ionising radiation ...
Aesthetic Disruptions: Critical Surveillance Art and the Unsettling of Surveillance
Aesthetic Disruptions: Critical Surveillance Art and the Unsettling of Surveillance
In the field of surveillance studies, scholars have focused on the use of art to offer an aesthetic intervention into the operation of surveillance systems. Scholars have used the ...
Evaluation Activities from the National Syndromic Surveillance Program
Evaluation Activities from the National Syndromic Surveillance Program
ObjectiveThe objective of this session is to discuss syndromic surveillance evaluation activities. Panel participants will describe contexts and importance of selected evaluation a...
Implementation Level of Event-Based Surveillance (EBS) as surveillance core capacity under international health regulation in Sudan, 2020: Cross-sectional study
Implementation Level of Event-Based Surveillance (EBS) as surveillance core capacity under international health regulation in Sudan, 2020: Cross-sectional study
Abstract
Background: Surveillance system of infectious diseases and event is recognized as the cornerstone of public health decision-making and practice additionally, the i...
SU‐GG‐T‐200: Comparison of a Novel Transmission Detector to a Standard Measurement Technique for Patient IMRT Quality Assurance
SU‐GG‐T‐200: Comparison of a Novel Transmission Detector to a Standard Measurement Technique for Patient IMRT Quality Assurance
Purpose: A new measurement‐based, pre‐treatment IMRT composite quality assurance (QA) procedure was compared to a standard QA method. The standard QA method consisted of delivering...
End-to-End Reservoir Surveillance Optimization Through Automated Value of Information Assessments
End-to-End Reservoir Surveillance Optimization Through Automated Value of Information Assessments
Abstract
Effective reservoir management requires continuous surveillance to monitor the reservoir's performance and optimize production. To facilitate this, we propo...
Feasibility study of shielded diode detector for small field dosimetry
Feasibility study of shielded diode detector for small field dosimetry
Abstract
Improved imaging techniques and modern radiotherapy treatment delivery in the treatment field are reduced to the precise size of the tumor, which necessitat...