Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Investigation on Laf3/Si Structure as Light-Addressable Potentiometric Fluoride (F‾) Sensor

View through CrossRef
In this article LaF3 films in LaF3/Si structure have been investigated for the measurement of fluoride ions in aqueous solution with higher accuracy using light-addressable potentiometric sensing technique. LaF3 films were directly grown on Si by vacuum evaporation. The effects of LaF3-thickness and annealing on the fluoride-sensitivity of the LaF3/Si structures have been studied. Accordingly four different LaF3/Si structures with various thickness of LaF3 (5/50/150nm) layer were fabricated. The structures are annealed at 400ºC for 10 minutes. The un-annealed LaF3/Si structures show very poor fluoride sensitivity. As predicted in the theoretical study structures with thinner LaF3 offer better steepness of the photocurrent characteristics that indicates better accuracy in fluoride concentration measurement. Among the annealed structures, the one prepared with 150nm LaF3 layer shows the best fluoride sensitivity of ≈ 54.5mV/pF in the range of pF1-pF4. Experimental results show a good promise for LaF3/Si structure as a light-addressable potentiometric sensor that can be used for the sensing and imaging the distribution of fluoride ion in aqueous medium with higher accuracy. Keywords: Light-addressable potentiometric sensor (LAPS), Fluoride sensor, Capacitive EIS structure
Title: Investigation on Laf3/Si Structure as Light-Addressable Potentiometric Fluoride (F‾) Sensor
Description:
In this article LaF3 films in LaF3/Si structure have been investigated for the measurement of fluoride ions in aqueous solution with higher accuracy using light-addressable potentiometric sensing technique.
LaF3 films were directly grown on Si by vacuum evaporation.
The effects of LaF3-thickness and annealing on the fluoride-sensitivity of the LaF3/Si structures have been studied.
Accordingly four different LaF3/Si structures with various thickness of LaF3 (5/50/150nm) layer were fabricated.
The structures are annealed at 400ºC for 10 minutes.
The un-annealed LaF3/Si structures show very poor fluoride sensitivity.
As predicted in the theoretical study structures with thinner LaF3 offer better steepness of the photocurrent characteristics that indicates better accuracy in fluoride concentration measurement.
Among the annealed structures, the one prepared with 150nm LaF3 layer shows the best fluoride sensitivity of ≈ 54.
5mV/pF in the range of pF1-pF4.
Experimental results show a good promise for LaF3/Si structure as a light-addressable potentiometric sensor that can be used for the sensing and imaging the distribution of fluoride ion in aqueous medium with higher accuracy.
 Keywords: Light-addressable potentiometric sensor (LAPS), Fluoride sensor, Capacitive EIS structure.

Related Results

Demonstration of Diode-Pumped Yb:LaF3 and Tm,Ho:LaF3 Lasers
Demonstration of Diode-Pumped Yb:LaF3 and Tm,Ho:LaF3 Lasers
Diode-pumped solid-state lasers using novel Yb:LaF3 and Tm,Ho:LaF3 crystals as laser gain materials are demonstrated herein. The Yb:LaF3 and Tm,Ho:LaF3 crystals were grown using th...
Biomarkers of Fluoride in Children Exposed to Different Sources of Systemic Fluoride
Biomarkers of Fluoride in Children Exposed to Different Sources of Systemic Fluoride
There has been no comparison between fluoride concentrations in urine and nails of children exposed to different sources of systemic fluoride. The aim of this study was to compare ...
Evaluation of free and total fluoride concentration in mouthwashes via measurement with ion-selective electrode
Evaluation of free and total fluoride concentration in mouthwashes via measurement with ion-selective electrode
Abstract Background: The aim of this study was to compare free fluoride concentration and total fluoride concentration in mouthwashes. Methods: Fluorine-containing mouthwas...
Evaluation of free and total fluoride concentration in mouthwashes via measurement with ion-selective electrode
Evaluation of free and total fluoride concentration in mouthwashes via measurement with ion-selective electrode
Abstract Background: The aim of this study was to compare free fluoride concentration and total fluoride concentration in mouthwashes. Methods: Fluorine-containing mouthwas...
Evaluation of free and total fluoride concentration in mouthwashes via measurement with ion-selective electrode
Evaluation of free and total fluoride concentration in mouthwashes via measurement with ion-selective electrode
Abstract Background: The aim of this study was to compare free fluoride concentration and total fluoride concentration in mouthwashes. Methods: Fluorine-containing mouthwas...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Bridging bones
Bridging bones
Chapter 2 presents the evaluation of the feasibility of utilizing whole-body [18F]Fluoride PET/CT for visualizing molecular new bone formation in clinically active PsA patients. Th...

Back to Top