Javascript must be enabled to continue!
Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files—An In Vitro Study
View through CrossRef
The aim of this study was to analyze and compare the influence of the geometrical cross-section design on the dynamic cyclic fatigue resistance of NiTi endodontic rotary files. Materials and Methods: Forty sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.06 double S-shaped cross-section NiTi alloy endodontic rotary files (Mtwo) (n = 10); B: 20.04 rectangular cross-section NiTi alloy endodontic rotary files (T Pro E1) (n = 10); C: 25.04 convex triangular cross-section NiTi alloy endodontic rotary files (T Pro E2) (n = 10); and D: 25.06 triangular cross-section NiTi alloy endodontic rotary files (T Pro E4) (n = 10). A cyclic fatigue device was used to conduct the static cyclic fatigue tests with stainless steel artificial root canal systems with 200 µm and 250 µm apical diameter, 60° curvature angle, 3 mm radius of curvature, 20 mm length, and 4% and 8% taper. The results were analyzed using the ANOVA test and Weibull statistical analysis. Results: All the pairwise comparisons presented statistically significant differences between the time to failure and number of cycles to failure for the cross-section design study groups (p < 0.001). Conclusions: the double S-shaped cross-section of Mtwo NiTi endodontic files shows higher cyclic fatigue resistance than the rectangular cross-section of T Pro E1 NiTi endodontic files, the convex triangular cross-section of T Pro E2 NiTi endodontic files, and the triangular cross-section of T Pro E4 NiTi endodontic files.
Title: Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files—An In Vitro Study
Description:
The aim of this study was to analyze and compare the influence of the geometrical cross-section design on the dynamic cyclic fatigue resistance of NiTi endodontic rotary files.
Materials and Methods: Forty sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.
06 double S-shaped cross-section NiTi alloy endodontic rotary files (Mtwo) (n = 10); B: 20.
04 rectangular cross-section NiTi alloy endodontic rotary files (T Pro E1) (n = 10); C: 25.
04 convex triangular cross-section NiTi alloy endodontic rotary files (T Pro E2) (n = 10); and D: 25.
06 triangular cross-section NiTi alloy endodontic rotary files (T Pro E4) (n = 10).
A cyclic fatigue device was used to conduct the static cyclic fatigue tests with stainless steel artificial root canal systems with 200 µm and 250 µm apical diameter, 60° curvature angle, 3 mm radius of curvature, 20 mm length, and 4% and 8% taper.
The results were analyzed using the ANOVA test and Weibull statistical analysis.
Results: All the pairwise comparisons presented statistically significant differences between the time to failure and number of cycles to failure for the cross-section design study groups (p < 0.
001).
Conclusions: the double S-shaped cross-section of Mtwo NiTi endodontic files shows higher cyclic fatigue resistance than the rectangular cross-section of T Pro E1 NiTi endodontic files, the convex triangular cross-section of T Pro E2 NiTi endodontic files, and the triangular cross-section of T Pro E4 NiTi endodontic files.
Related Results
The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device
The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device
The aim of this study was to analyze the effect of the taper and apical diameter of nickel–titanium (NiTi) endodontic rotary files on the dynamic cyclic fatigue resistance. A total...
The Influence of NiTi Alloy on the Cyclic Fatigue Resistance of Endodontic Files
The Influence of NiTi Alloy on the Cyclic Fatigue Resistance of Endodontic Files
Background: The aim of this study was to analyze the influence of NiTi alloy in endodontic rotary instruments on cyclic fatigue resistance. Methods: One hundred and sixty-four (164...
Effect of Rotational Speed on the Resistance of NiTi Alloy Endodontic Rotary Files to Cyclic Fatigue—An In Vitro Study
Effect of Rotational Speed on the Resistance of NiTi Alloy Endodontic Rotary Files to Cyclic Fatigue—An In Vitro Study
The present study aims to evaluate and contrast the function of the rotational speed of NiTi alloy endodontic rotary files on how resistant they are to dynamic cyclic fatigue. Meth...
Comparative Analysis of Ease of Removal of Fractured NiTi Endodontic Rotary Files from the Root Canal System—An In Vitro Study
Comparative Analysis of Ease of Removal of Fractured NiTi Endodontic Rotary Files from the Root Canal System—An In Vitro Study
This study aimed at analyzing and comparing the ease of removal of fractured nickel–titanium (NiTi) endodontic rotary files from the root canal system between the ultrasonic tips a...
Effect of Cryogenic Treatment on Cyclic Fatigue of Nickel-titanium Rotary Files
Effect of Cryogenic Treatment on Cyclic Fatigue of Nickel-titanium Rotary Files
Abstract
Objective: This study sought to assess the effect of cryogenic treatment on cyclic fatigue of Neoniti and Reciproc nickel-titanium (NiTi) rotary files. This in vi...
Pediatric Rotary Files: Evolution to Revolution
Pediatric Rotary Files: Evolution to Revolution
The main goal of pulp therapy in primary dentition is to preserve the primary tooth thus protecting future normal occlusion. Routinely, pulp debridement and canal shaping ar...
Microstructure and Phase Transition Characteristics of NiTi Shape Memory Alloy
Microstructure and Phase Transition Characteristics of NiTi Shape Memory Alloy
Abstract
Shape memory alloy (SMA) with shape memory effect and superelasticity has had an increasing interest for researchers of mechanics of materials in recent dec...
Cyclic Fatigue and Fracture Resistance in Contemporary Rotary File Systems: An Evidence-Based Review
Cyclic Fatigue and Fracture Resistance in Contemporary Rotary File Systems: An Evidence-Based Review
Nickel-titanium (NiTi) rotary endodontic instruments have revolutionized root canal treatment. However, their clinical performance can be influenced by various factors, including m...