Abstract
Objective: This study sought to assess the effect of cryogenic treatment on cyclic fatigue of Neoniti and Reciproc nickel-titanium (NiTi) rotary files. This in vitro, experimental study was performed on 48 Neoniti and Reciproc NiTi rotary files (#25, 6% taper) in two subgroups with and without cryogenic treatment. The files in cryogenic subgroups were stored in liquid nitrogen chamber at -196°C for 24 h. Next, they were placed at room temperature (25°C) to gradually warm up. Stainless steel (SS) blocks were used to standardize the degree of rotation of the files. The SS blocks simulated a root canal with the negative pattern of gutta-percha with 0.08 taper, #25 tip size, and 45° canal curvature. Each endodontic file was rotated in this canal until fracture. The time until fracture was recorded by a digital chronometer. Time to fracture was used to calculate the number of rotations before file fracture as the cyclic fatigue scale. Results: The mean cyclic fatigue resistance of both Neoniti and Reciproc rotary files in cryogenic subgroups was significantly higher than that in non-cryogenic control subgroups (P<0.05). Cryogenic treatment can significantly increase the cyclic fatigue resistance of Neoniti and Reciproc NiTi rotary files.
Research Square Platform LLC
Title: Effect of Cryogenic Treatment on Cyclic Fatigue of Nickel-titanium Rotary Files
Description:
Abstract
Objective: This study sought to assess the effect of cryogenic treatment on cyclic fatigue of Neoniti and Reciproc nickel-titanium (NiTi) rotary files.
This in vitro, experimental study was performed on 48 Neoniti and Reciproc NiTi rotary files (#25, 6% taper) in two subgroups with and without cryogenic treatment.
The files in cryogenic subgroups were stored in liquid nitrogen chamber at -196°C for 24 h.
Next, they were placed at room temperature (25°C) to gradually warm up.
Stainless steel (SS) blocks were used to standardize the degree of rotation of the files.
The SS blocks simulated a root canal with the negative pattern of gutta-percha with 0.
08 taper, #25 tip size, and 45° canal curvature.
Each endodontic file was rotated in this canal until fracture.
The time until fracture was recorded by a digital chronometer.
Time to fracture was used to calculate the number of rotations before file fracture as the cyclic fatigue scale.
Results: The mean cyclic fatigue resistance of both Neoniti and Reciproc rotary files in cryogenic subgroups was significantly higher than that in non-cryogenic control subgroups (P<0.
05).
Cryogenic treatment can significantly increase the cyclic fatigue resistance of Neoniti and Reciproc NiTi rotary files.
Related Results
EFEKTIVITAS YOGA UNTUK MENGURANGI FATIGUE PADA PASIEN KANKER YANG MENJALANI KEMOTERAPI
EFEKTIVITAS YOGA UNTUK MENGURANGI FATIGUE PADA PASIEN KANKER YANG MENJALANI KEMOTERAPI
ABSTRAKLatar Belakang : Cancer Related Fatigue (CRF) adalah manifestasi klinis yang serius dan gejala umum yang dialami oleh pasien kanker. Fatigue adalah salah satu yang paling se...
Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files—An In Vitro Study
Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files—An In Vitro Study
The aim of this study was to analyze and compare the influence of the geometrical cross-section design on the dynamic cyclic fatigue resistance of NiTi endodontic rotary files. Mat...
Pediatric Rotary Files: Evolution to Revolution
Pediatric Rotary Files: Evolution to Revolution
The main goal of pulp therapy in primary dentition is to preserve the primary tooth thus protecting future normal occlusion. Routinely, pulp debridement and canal shaping ar...
The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device
The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device
The aim of this study was to analyze the effect of the taper and apical diameter of nickel–titanium (NiTi) endodontic rotary files on the dynamic cyclic fatigue resistance. A total...
Potency Of Manual Instrumentation To The Rotary Instrumentation For Primary Teeth Pulpectomies: A Clinical Comparrative Study
Potency Of Manual Instrumentation To The Rotary Instrumentation For Primary Teeth Pulpectomies: A Clinical Comparrative Study
Background: Using hand files in primary teeth is time-consuming, can lead to the formation of unwanted curvatures, and can cause iatrogenic errors. To overcome these difficulties, ...
Fatigue damage propagation of
FRP
under coupling effect of cyclic load and corrosion
Fatigue damage propagation of
FRP
under coupling effect of cyclic load and corrosion
Abstract
Interlaminar fracture or delamination is one of the major failure modes for fiber reinfo...
Assessment of Objective and Subjective Fatigubility in Obese
Assessment of Objective and Subjective Fatigubility in Obese
Aim: This study aimed to quantify objective fatigue using the Long Distance Corridor Walk (2-Minute Walk Test and 400-Meter Walk Test) and evaluate subjective fatigue using the Fat...
The Influence of NiTi Alloy on the Cyclic Fatigue Resistance of Endodontic Files
The Influence of NiTi Alloy on the Cyclic Fatigue Resistance of Endodontic Files
Background: The aim of this study was to analyze the influence of NiTi alloy in endodontic rotary instruments on cyclic fatigue resistance. Methods: One hundred and sixty-four (164...