Javascript must be enabled to continue!
The Influence of NiTi Alloy on the Cyclic Fatigue Resistance of Endodontic Files
View through CrossRef
Background: The aim of this study was to analyze the influence of NiTi alloy in endodontic rotary instruments on cyclic fatigue resistance. Methods: One hundred and sixty-four (164) sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.08 F2 ProTaper Universal (PTU) (n = 41); B: 25.06 X2 ProTaper Next (PTN) (n = 41); C: 25.08 F2 ProTaper Gold (PTG) (n = 41), and D: 25.06 ProFile Vortex Blue (PVB) (n = 41). A cyclic fatigue device was designed to conduct the static cyclic fatigue tests with stainless steel artificial root canals systems with 250 µm apical diameter, 60° curvature angle, 5 mm radius of curvature, 20 mm length, and 6% (25.06) and 8% taper (25.08). Failure of the endodontic rotary instrument was detected by a single operator through direct observation and was also filmed to allow measurement of the exact time to failure. Results were analyzed using the ANOVA test and Weibull statistical analysis. Results: All pairwise comparisons presented statistically significant differences between the time to failure for the NiTi alloy study groups (p < 0.001), except between the PTN and PVB study groups (p = 0.379). In addition, statistically significant differences between the number of cycles to failure for the NiTi alloy study groups (p < 0.001) were also observed. Conclusions: The NiTi CM-Gold wire alloy of the ProTaper Gold endodontic rotary files resulted in greater resistance to cyclic fatigue than ProFile Vortex Blue, ProTaper Next, and ProTaper Universal endodontic rotary files.
Title: The Influence of NiTi Alloy on the Cyclic Fatigue Resistance of Endodontic Files
Description:
Background: The aim of this study was to analyze the influence of NiTi alloy in endodontic rotary instruments on cyclic fatigue resistance.
Methods: One hundred and sixty-four (164) sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.
08 F2 ProTaper Universal (PTU) (n = 41); B: 25.
06 X2 ProTaper Next (PTN) (n = 41); C: 25.
08 F2 ProTaper Gold (PTG) (n = 41), and D: 25.
06 ProFile Vortex Blue (PVB) (n = 41).
A cyclic fatigue device was designed to conduct the static cyclic fatigue tests with stainless steel artificial root canals systems with 250 µm apical diameter, 60° curvature angle, 5 mm radius of curvature, 20 mm length, and 6% (25.
06) and 8% taper (25.
08).
Failure of the endodontic rotary instrument was detected by a single operator through direct observation and was also filmed to allow measurement of the exact time to failure.
Results were analyzed using the ANOVA test and Weibull statistical analysis.
Results: All pairwise comparisons presented statistically significant differences between the time to failure for the NiTi alloy study groups (p < 0.
001), except between the PTN and PVB study groups (p = 0.
379).
In addition, statistically significant differences between the number of cycles to failure for the NiTi alloy study groups (p < 0.
001) were also observed.
Conclusions: The NiTi CM-Gold wire alloy of the ProTaper Gold endodontic rotary files resulted in greater resistance to cyclic fatigue than ProFile Vortex Blue, ProTaper Next, and ProTaper Universal endodontic rotary files.
Related Results
Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files—An In Vitro Study
Influence of the Geometrical Cross-Section Design on the Dynamic Cyclic Fatigue Resistance of NiTi Endodontic Rotary Files—An In Vitro Study
The aim of this study was to analyze and compare the influence of the geometrical cross-section design on the dynamic cyclic fatigue resistance of NiTi endodontic rotary files. Mat...
The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device
The Effect of Taper and Apical Diameter on the Cyclic Fatigue Resistance of Rotary Endodontic Files Using an Experimental Electronic Device
The aim of this study was to analyze the effect of the taper and apical diameter of nickel–titanium (NiTi) endodontic rotary files on the dynamic cyclic fatigue resistance. A total...
Microstructure and Phase Transition Characteristics of NiTi Shape Memory Alloy
Microstructure and Phase Transition Characteristics of NiTi Shape Memory Alloy
Abstract
Shape memory alloy (SMA) with shape memory effect and superelasticity has had an increasing interest for researchers of mechanics of materials in recent dec...
Effect of Rotational Speed on the Resistance of NiTi Alloy Endodontic Rotary Files to Cyclic Fatigue—An In Vitro Study
Effect of Rotational Speed on the Resistance of NiTi Alloy Endodontic Rotary Files to Cyclic Fatigue—An In Vitro Study
The present study aims to evaluate and contrast the function of the rotational speed of NiTi alloy endodontic rotary files on how resistant they are to dynamic cyclic fatigue. Meth...
Comparative Analysis of Ease of Removal of Fractured NiTi Endodontic Rotary Files from the Root Canal System—An In Vitro Study
Comparative Analysis of Ease of Removal of Fractured NiTi Endodontic Rotary Files from the Root Canal System—An In Vitro Study
This study aimed at analyzing and comparing the ease of removal of fractured nickel–titanium (NiTi) endodontic rotary files from the root canal system between the ultrasonic tips a...
Effect of Cryogenic Treatment on Cyclic Fatigue of Nickel-titanium Rotary Files
Effect of Cryogenic Treatment on Cyclic Fatigue of Nickel-titanium Rotary Files
Abstract
Objective: This study sought to assess the effect of cryogenic treatment on cyclic fatigue of Neoniti and Reciproc nickel-titanium (NiTi) rotary files. This in vi...
Cyclic Fatigue of Different Ni-Ti Endodontic Rotary File Alloys: A Comprehensive Review
Cyclic Fatigue of Different Ni-Ti Endodontic Rotary File Alloys: A Comprehensive Review
Introduction: Modern endodontics aims to decrease the bacterial load from the complex endodontic space. Over the years, improvements in the operative phases have led to a considera...
Assessment of Objective and Subjective Fatigubility in Obese
Assessment of Objective and Subjective Fatigubility in Obese
Aim: This study aimed to quantify objective fatigue using the Long Distance Corridor Walk (2-Minute Walk Test and 400-Meter Walk Test) and evaluate subjective fatigue using the Fat...

