Javascript must be enabled to continue!
Cavitation Erosion Performance of Steel, Ceramics, Carbide, and Victrex PEEK Materials
View through CrossRef
Abstract
Cavitation erosion has to be taken into consideration during material selection in many industrial sectors, e.g., offshore, marine, and oil and gas, in which components operate under severe working conditions. The cavitation erosion equipment, located at the University of Southampton, uses a vibratory apparatus to compare, rank, and characterize the cavitation erosion performance of materials. This article highlights some of the results obtained from industrial research (consultancy) work employing a Hielscher UIP1000hd 20 kHz ultrasonic transducer (Hielscher Ultrasonics GmbH, Teltow, Germany). The transducer is attached to a titanium horn to induce the formation and collapse of cavities in a liquid, creating erosion (material loss) of the specimen undergoing testing. The results from erosion cavitation testing (in accordance with ASTM G32-16, Standard Test Method for Cavitation Erosion Using Vibratory Apparatus (Superseded)) of two commercially available steels are presented herein and are shown to have less resistance to cavitation when compared to polyether(ether ketone), ceramic, and carbide materials. These materials are presented, along with Nickel 200, which was used to normalize the results. A plot of cumulative erosion versus exposure time was determined by periodic interruption of the test.
ASTM International
Title: Cavitation Erosion Performance of Steel, Ceramics, Carbide, and Victrex PEEK Materials
Description:
Abstract
Cavitation erosion has to be taken into consideration during material selection in many industrial sectors, e.
g.
, offshore, marine, and oil and gas, in which components operate under severe working conditions.
The cavitation erosion equipment, located at the University of Southampton, uses a vibratory apparatus to compare, rank, and characterize the cavitation erosion performance of materials.
This article highlights some of the results obtained from industrial research (consultancy) work employing a Hielscher UIP1000hd 20 kHz ultrasonic transducer (Hielscher Ultrasonics GmbH, Teltow, Germany).
The transducer is attached to a titanium horn to induce the formation and collapse of cavities in a liquid, creating erosion (material loss) of the specimen undergoing testing.
The results from erosion cavitation testing (in accordance with ASTM G32-16, Standard Test Method for Cavitation Erosion Using Vibratory Apparatus (Superseded)) of two commercially available steels are presented herein and are shown to have less resistance to cavitation when compared to polyether(ether ketone), ceramic, and carbide materials.
These materials are presented, along with Nickel 200, which was used to normalize the results.
A plot of cumulative erosion versus exposure time was determined by periodic interruption of the test.
Related Results
Numerical Modelling of Cavitation Erosion
Numerical Modelling of Cavitation Erosion
The goal of the work is to develop an expert system for monitoring and control of cavitation in hydraulic machines and to research the possibility of cavitation erosion prediction ...
Effect of coping materials zirconia or polyetheretherketone with different techniques of fabrication on vertical marginal gap and fracture resistance of posterior crowns with composite veneering
Effect of coping materials zirconia or polyetheretherketone with different techniques of fabrication on vertical marginal gap and fracture resistance of posterior crowns with composite veneering
Abstract
Background
Insufficient research has been conducted in the literature assessing the performance of zirconia and polyetheretherketone (PEEK)...
CFD INVESTIGATION OF TURBULENT WATER FLOW IN A PIPE ELBOW: ASSESSMENT OF CAVITATION RISK
CFD INVESTIGATION OF TURBULENT WATER FLOW IN A PIPE ELBOW: ASSESSMENT OF CAVITATION RISK
Cavitation represents the formation and subsequent collapse of vapor or gas bubbles in the vicinity of solid surfaces. Depending on the mechanism of initiation, cavitation can be c...
Surface modification of PEEK implants for craniofacial reconstruction and aesthetic augmentation—fiction or reality?
Surface modification of PEEK implants for craniofacial reconstruction and aesthetic augmentation—fiction or reality?
Facial implantology, a crucial facet of plastic and reconstructive surgery, focuses on optimizing implant materials for facial augmentation and reconstruction. This manuscript expl...
Study on Unsteady Cavitation Flow and Pressure Pulsation Characteristics in the Regulating Valve
Study on Unsteady Cavitation Flow and Pressure Pulsation Characteristics in the Regulating Valve
A combined numerical‐experiment investigation on the unsteady cavitation flow and pressure fluctuation characteristics in the regulating valves is conducted in this paper. The cavi...
EVALUATION OF CAVITATION PERFORMANCE OF AN AXI-SYMMETRIC BODY WITH PUMPJET PROPULSOR
EVALUATION OF CAVITATION PERFORMANCE OF AN AXI-SYMMETRIC BODY WITH PUMPJET PROPULSOR
A Pumpjet (PJP) was designed for an underwater body (UWB) with an axi-symmetric configuration as part of a technology development program for design and development of pumpjet. Its...
Ultrasound stimulated microbubbles cavitation enhanced the therapeutic effect of colchicine in rats with acute gouty arthritis
Ultrasound stimulated microbubbles cavitation enhanced the therapeutic effect of colchicine in rats with acute gouty arthritis
Abstract
Objective
To investigate whether cavitation induced by ultrasound stimulated microbubbles (USMB) can enhance the therapeutic effect of colchicine and reduce its s...
The Role of Polyether Ether Ketone (Peek) in Dentistry – A Review
The Role of Polyether Ether Ketone (Peek) in Dentistry – A Review
This study is aimed to review the applications of Polyether Ether Ketone (PEEK) in dentistry. The increased demand for aesthetics, legislation in some developed countries, few draw...