Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Tolerance and Nature of Residual Refraction in Symmetric Power Space as Principal Lens Powers and Meridians Change

View through CrossRef
Unacceptable principal powers in well-centred lenses may require a toric over-refraction which differs in nature from the one where correct powers have misplaced meridians. This paper calculates residual (over) refractions and their natures. The magnitude of the power of the over-refraction serves as a general, reliable, real scalar criterion for acceptance or tolerance of lenses whose surface relative curvatures change or whose meridians are rotated and cause powers to differ. Principal powers and meridians of lenses are analogous to eigenvalues and eigenvectors of symmetric matrices, which facilitates the calculation of powers and their residuals. Geometric paths in symmetric power space link intended refractive correction and these carefully chosen, undue refractive corrections. Principal meridians alone vary along an arc of a circle centred at the origin and corresponding powers vary autonomously along select diameters of that circle in symmetric power space. Depending on the path of the power change, residual lenses different from their prescription in principal powers and meridians are pure cross-cylindrical or spherocylindrical in nature. The location of residual power in symmetric dioptric power space and its optical cross-representation characterize the lens that must be added to the compensation to attain the power in the prescription.
Title: Tolerance and Nature of Residual Refraction in Symmetric Power Space as Principal Lens Powers and Meridians Change
Description:
Unacceptable principal powers in well-centred lenses may require a toric over-refraction which differs in nature from the one where correct powers have misplaced meridians.
This paper calculates residual (over) refractions and their natures.
The magnitude of the power of the over-refraction serves as a general, reliable, real scalar criterion for acceptance or tolerance of lenses whose surface relative curvatures change or whose meridians are rotated and cause powers to differ.
Principal powers and meridians of lenses are analogous to eigenvalues and eigenvectors of symmetric matrices, which facilitates the calculation of powers and their residuals.
Geometric paths in symmetric power space link intended refractive correction and these carefully chosen, undue refractive corrections.
Principal meridians alone vary along an arc of a circle centred at the origin and corresponding powers vary autonomously along select diameters of that circle in symmetric power space.
Depending on the path of the power change, residual lenses different from their prescription in principal powers and meridians are pure cross-cylindrical or spherocylindrical in nature.
The location of residual power in symmetric dioptric power space and its optical cross-representation characterize the lens that must be added to the compensation to attain the power in the prescription.

Related Results

Components of Lens Power That Regulate Surface Principal Powers and Relative Meridians Independently
Components of Lens Power That Regulate Surface Principal Powers and Relative Meridians Independently
Paraxial light rays incident in air on alternate refracting surfaces of a thick lens can yield complementary powers. This paper aims to test when these powers are invariant as surf...
A focusing method on refraction topography measurement
A focusing method on refraction topography measurement
AbstractThis paper introduces a novel focusing method Refraction Topography (RT) for wide-angle refraction measurement. The agreement of the test results obtained using RT is evalu...
Morphometric OCT parameters of the lens under accommodative stimulus. Report 1. Assessment of age-related changes
Morphometric OCT parameters of the lens under accommodative stimulus. Report 1. Assessment of age-related changes
Introduction. The structural approach to studying the mechanism of accommodation and its age-related changes focuses on analyzing morphometric parameters (size, shape, and position...
Paraxial Ocular Measurements and Entries in Spectral and Modal Matrices: Analogy and Application
Paraxial Ocular Measurements and Entries in Spectral and Modal Matrices: Analogy and Application
Lensometers and keratometers yield powers along perpendicular meridians even if the principal meridians of the lens and the cornea are oblique. From each such instrument, multiple ...
Mapping of error cells in clinical measure to symmetric power space
Mapping of error cells in clinical measure to symmetric power space
AbstractDuring the refraction procedure, the power of the nearest equivalent sphere lens, known as the scalar power, is conserved within upper and lower bounds in the sphere (and c...
Seditious Spaces
Seditious Spaces
The title ‘Seditious Spaces’ is derived from one aspect of Britain’s colonial legacy in Malaysia (formerly Malaya): the Sedition Act 1948. While colonial rule may seem like it was ...
SEPARATION OF POWERS IN THE RUSSIAN SYSTEM OF FISCAL FEDERALISM
SEPARATION OF POWERS IN THE RUSSIAN SYSTEM OF FISCAL FEDERALISM
The aim of the research is to identify the main trends in separation of powers of the Russian Federation and subjects of the Russian Federation in the context of the new federal la...

Back to Top