Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A focusing method on refraction topography measurement

View through CrossRef
AbstractThis paper introduces a novel focusing method Refraction Topography (RT) for wide-angle refraction measurement. The agreement of the test results obtained using RT is evaluated against simulation results and expected refraction. RT develops a refraction algorithm on fundus images at various focusing statuses. Unlike conventional techniques for peripheral refraction measurement, RT requires the subject to stare at a stationary fixation target. The refraction algorithm calculates the focus measure for multiple images at the Point of Interest and formulates them into a focus profile. The maximum focus measure correlates with the optimal focus position. Refraction Characterization Function (RCF) is proposed to translate the focus position into refraction determination, thus forming the refraction topography. The refraction characterization of RT optical system is performed using Isabel schematic eye. Three test eyes of − 15 D, 0 D, and + 15 D are defined, and expected refraction is obtained through simulation on an independent test schematic eye. Both simulation results and experimental results are obtained by combining the test eyes and RT system. Test results are compared with simulation results and expected refraction. The study demonstrates agreement among the test results, simulation results, and expected refraction on three test eyes.
Title: A focusing method on refraction topography measurement
Description:
AbstractThis paper introduces a novel focusing method Refraction Topography (RT) for wide-angle refraction measurement.
The agreement of the test results obtained using RT is evaluated against simulation results and expected refraction.
RT develops a refraction algorithm on fundus images at various focusing statuses.
Unlike conventional techniques for peripheral refraction measurement, RT requires the subject to stare at a stationary fixation target.
The refraction algorithm calculates the focus measure for multiple images at the Point of Interest and formulates them into a focus profile.
The maximum focus measure correlates with the optimal focus position.
Refraction Characterization Function (RCF) is proposed to translate the focus position into refraction determination, thus forming the refraction topography.
The refraction characterization of RT optical system is performed using Isabel schematic eye.
Three test eyes of − 15 D, 0 D, and + 15 D are defined, and expected refraction is obtained through simulation on an independent test schematic eye.
Both simulation results and experimental results are obtained by combining the test eyes and RT system.
Test results are compared with simulation results and expected refraction.
The study demonstrates agreement among the test results, simulation results, and expected refraction on three test eyes.

Related Results

LADARWave Wavefront Measurement in Normal Eyes
LADARWave Wavefront Measurement in Normal Eyes
ABSTRACT PURPOSE: We evaluated the correlation of Alcon LADARWave wavefront measurements with clinical refraction and corneal topography. METHODS: In a retrospe...
A Global Map of Renormalised Mantle Dynamic Topography
A Global Map of Renormalised Mantle Dynamic Topography
<p>Comparison of predicted mantle dynamic topography with observed residual topography shows that the amplitude of predicted dynamic topography is too great (Cowie &a...
The impact of accommodation function on the difference between noncycloplegic and cycloplegic refraction in adult myopes
The impact of accommodation function on the difference between noncycloplegic and cycloplegic refraction in adult myopes
AbstractPurposeTo investigate the impact of accommodation function on the difference between cycloplegic and noncycloplegic subjective and automatic refraction in adult myopes.Meth...
Geoid and topography on Venus: Isostatic or dynamic?
Geoid and topography on Venus: Isostatic or dynamic?
Venus is commonly described as Earth’s slightly smaller twin planet. However, the dynamics of plate tectonics present at Earth are not observed at Venus.  Gravit...
Effect of frequency difference deviation on full-field heterodyne measurement accuracy
Effect of frequency difference deviation on full-field heterodyne measurement accuracy
With the advantages of high precision and great environmental adaptability, laser heterodyne interferometry has been successfullyused in some areas, such as measuring distance and ...
Побачивши особистості геодезії та картографії (Вітковський В.В.)
Побачивши особистості геодезії та картографії (Вітковський В.В.)
March 20 marks the 95th anniversary of the death of one of Russia's most famous geodetic cartographers, a professor, a military geodesist, a member of the Geographical Society Vasy...
Refraction-aware Structure-from-Motion for Airborne Bathymetry
Refraction-aware Structure-from-Motion for Airborne Bathymetry
In this work, we introduce the first pipeline that combines a refraction-aware Structure-from-Motion (SfM) method with a deep learning model specifically designed for airborne bath...
Biometry and Intraocular Lens Power Calculation by Combined Scheimpflug-Placido Disc versus Optical Interferometry Devices
Biometry and Intraocular Lens Power Calculation by Combined Scheimpflug-Placido Disc versus Optical Interferometry Devices
Purpose: To compare the results of the current gold standard, laser interferometry, and keratometry by the IOL-Master, with a newly developed Galilei G6 using raytracing software O...

Back to Top