Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Cervical pedicle screw fixation with the Tianji orthopedic surgical robot.

View through CrossRef
Abstract Objective To compare the accuracy and safety of implanting cervical pedicle screws (CPS) between orthopedic surgical robot-assisted technique and traditional fluoroscopy-assisted free-hand technique. Methods Retrospective analysis of 95 patients treated with posterior cervical spinal surgery using either Tianji orthopedic surgical robot-assisted or traditional fluoroscopy-assisted free-hand pedicle screw implantation technology from March 2021 to March 2024, including 44 cases in the orthopedic surgical robot group and 51 cases in the traditional fluoroscopy group. Results Compared with the traditional fluoroscopy group, the orthopedic surgical robot group had better accuracy in screw implantation that is, a higher acceptable rate of screws (p = 0.0083). In addition, compared with the traditional fluoroscopy group, postoperative hospital stay was shorter in the orthopedic surgical robot group (p = 0.0447), but operation duration was longer (p = 0.0038). There was no significant difference in intraoperative blood loss between groups (p = 0.0872). There were 2 cases of cerebrospinal fluid leakage and 1 case of decreased left handgrip strength in the traditional fluoroscopy group, while only 1 case of cerebrospinal fluid leakage occurred in the orthopedic surgical robot group. Conclusions In this retrospective study, the accuracy of spine surgery with CSP implantation assisted by orthopedic surgical robot is often superior to that of spine surgery using traditional fluoroscopy-guided CPS implantation technique, while maintaining comparable safety.
Springer Science and Business Media LLC
Title: Cervical pedicle screw fixation with the Tianji orthopedic surgical robot.
Description:
Abstract Objective To compare the accuracy and safety of implanting cervical pedicle screws (CPS) between orthopedic surgical robot-assisted technique and traditional fluoroscopy-assisted free-hand technique.
Methods Retrospective analysis of 95 patients treated with posterior cervical spinal surgery using either Tianji orthopedic surgical robot-assisted or traditional fluoroscopy-assisted free-hand pedicle screw implantation technology from March 2021 to March 2024, including 44 cases in the orthopedic surgical robot group and 51 cases in the traditional fluoroscopy group.
Results Compared with the traditional fluoroscopy group, the orthopedic surgical robot group had better accuracy in screw implantation that is, a higher acceptable rate of screws (p = 0.
0083).
In addition, compared with the traditional fluoroscopy group, postoperative hospital stay was shorter in the orthopedic surgical robot group (p = 0.
0447), but operation duration was longer (p = 0.
0038).
There was no significant difference in intraoperative blood loss between groups (p = 0.
0872).
There were 2 cases of cerebrospinal fluid leakage and 1 case of decreased left handgrip strength in the traditional fluoroscopy group, while only 1 case of cerebrospinal fluid leakage occurred in the orthopedic surgical robot group.
Conclusions In this retrospective study, the accuracy of spine surgery with CSP implantation assisted by orthopedic surgical robot is often superior to that of spine surgery using traditional fluoroscopy-guided CPS implantation technique, while maintaining comparable safety.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Cervical pedicle screw fixation with the Tianji orthopedic surgical robot
Cervical pedicle screw fixation with the Tianji orthopedic surgical robot
Abstract Objective To compare the accuracy and safety of implanting cervical pedicle screws (CPS) between orthopedic surg...
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
When used in combination with decompression, spinal fusion is a successful procedure for treating patients with spinal stenosis and degenerative spondylolisthesis. While a number o...
Biomechanical characterization of bilateral pedicle screw internal fixation combinations on lumbar vertebrae
Biomechanical characterization of bilateral pedicle screw internal fixation combinations on lumbar vertebrae
Purpose Pedicle screw fixation has been considered a suitable surgical intervention for addressing a diverse range of indications involving the lumbar spinal segments, but the...
INTERNAL FIXATION SURGERY USING TIANJI ORTHOPEDIC ROBOT ON PATIENT SATISFACTION AND QUALITY OF LIFE
INTERNAL FIXATION SURGERY USING TIANJI ORTHOPEDIC ROBOT ON PATIENT SATISFACTION AND QUALITY OF LIFE
Internal fixation (IF) surgery has promoted with the combination of robotic technology, promising increased accuracy and improved patient prognosis. This study examined the effect ...
Influence of Different Fixed System in Osteoporotic Lumbar Vertebrae in Fusion:A 3D Finite Element Analysis
Influence of Different Fixed System in Osteoporotic Lumbar Vertebrae in Fusion:A 3D Finite Element Analysis
Abstract Background:Posterior lumbar interbody fusion(PLIF) is the most common surgical method for lumbar fusion surgery, and pedicle screws(PS)can provide effective fixati...
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
There are no published biomechanical studies evaluating the effect of stabilization techniques on the stability of the 3D printed models of the canine lumbosacral junction. The p...

Back to Top