Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A Comparative Study of Intraocular Pressure Measurements by Goldmann Applanation Tonometer and Schiotztonometer and the Study of Schiotz Tonometer a Screening Tool in North Karnataka Population

View through CrossRef
Background: Glaucoma is a multifactorial disease with common end point characteristics affecting the optic nerve.It is defined as an optic neuropathy characterised by specific structural findings in the optic disc (increased VerticalCup Disc Ratio (VCDR) or VCDR asymmetry >97.5 percentile) and particular functional deficits in automatedvisual field testing. It consists of three components: the optic nerve head, the visualfield, and intraocular pressure.Detecting the intraocular pressure is essential in not only initiating treatment, but also in monitoring the responseto treatment.Method: 210 purposively selected patients were subjected to three methods of tonometry – Goldmannapplanationtonometry, Schiotz indentation tonometry (with the 5.5g, 7.5g and 10 g weights). Three recordings were obtainedwith each method and the arithmetic mean taken as the intraocular pressure. The data was statistically analyzedusing the intra-class correlation coefficient. Sensitivity and specificity were also calculated for the Schiotz tonometer.Results: The Schiotz tonometer showed fair agreement with the Gold mannapplanationtonometer. The Schiotztonometer scored low as an effective screening tool.Conclusion: The current study shows that the Schiotz tonometer compares favourably with theGoldmannapplanation tonometer showing fair agreement with it. It showed good specificity and was reliable indetection of positives, excluding false positives.
Title: A Comparative Study of Intraocular Pressure Measurements by Goldmann Applanation Tonometer and Schiotztonometer and the Study of Schiotz Tonometer a Screening Tool in North Karnataka Population
Description:
Background: Glaucoma is a multifactorial disease with common end point characteristics affecting the optic nerve.
It is defined as an optic neuropathy characterised by specific structural findings in the optic disc (increased VerticalCup Disc Ratio (VCDR) or VCDR asymmetry >97.
5 percentile) and particular functional deficits in automatedvisual field testing.
It consists of three components: the optic nerve head, the visualfield, and intraocular pressure.
Detecting the intraocular pressure is essential in not only initiating treatment, but also in monitoring the responseto treatment.
Method: 210 purposively selected patients were subjected to three methods of tonometry – Goldmannapplanationtonometry, Schiotz indentation tonometry (with the 5.
5g, 7.
5g and 10 g weights).
Three recordings were obtainedwith each method and the arithmetic mean taken as the intraocular pressure.
The data was statistically analyzedusing the intra-class correlation coefficient.
Sensitivity and specificity were also calculated for the Schiotz tonometer.
Results: The Schiotz tonometer showed fair agreement with the Gold mannapplanationtonometer.
The Schiotztonometer scored low as an effective screening tool.
Conclusion: The current study shows that the Schiotz tonometer compares favourably with theGoldmannapplanation tonometer showing fair agreement with it.
It showed good specificity and was reliable indetection of positives, excluding false positives.

Related Results

Comparison of Intraocular Pressure Measurement by iCare Tonometer and Goldman Applanation Tonometer
Comparison of Intraocular Pressure Measurement by iCare Tonometer and Goldman Applanation Tonometer
  Objective: To compare the Intraocular Pressure measured by the Goldmann Applanation tonometer with by iCare ic100 tonometer in normal human eye to determine the accuracy and reli...
Changes in Intraocular Pressure After Laser in situ Keratomileusis
Changes in Intraocular Pressure After Laser in situ Keratomileusis
ABSTRACT PURPOSE: To evaluate changes in intraocular pressure (IOP) measurements by Goldmann applanation tonometry after laser in situ keratomileusis (LASIK) for myopia a...
Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
Implantable arterial blood pressure sensor
Implantable arterial blood pressure sensor
Although blood pressure measurements are well developed, the existing technology in the field of Arterial Blood Pressure (ABP) measurements is not sufficient in terms of long-term ...
Effect of Corneal Hydration on Goldmann Applanation Tonometry and Corneal Topography
Effect of Corneal Hydration on Goldmann Applanation Tonometry and Corneal Topography
ABSTRACT BACKGROUND: Measured ocular tension is reported to be positively related to corneal thickness. It has been speculated that an edematous cornea will cause low mea...
Effect of a tight necktie on intraocular pressure
Effect of a tight necktie on intraocular pressure
Introduction. Any factor causing constriction of the neck may lead to an increase in intraocular pressure. A tight necktie may result in increasing intraocular pressure, whic...
How Often the Goldmann Applanation Tonometer Should be Checked for Calibration Error?
How Often the Goldmann Applanation Tonometer Should be Checked for Calibration Error?
Purpose: To evaluate the frequency of Goldmann applanation tonometer (GAT) calibration error (CE) check. Methods: One obse...

Back to Top