EVALUASI TEKANAN JARINGAN DISTRIBUSI ZONA AIR MINUM PRIMA (ZAMP) PDAM INTAN BANJAR MENGGUNAKAN EPANET 2.0

View through CrossRef
PDAM Intan Banjar melakukan sebuah program untuk meningkatkan kualitas Air Minum yang disebut Zona Air Minum Prima (ZAMP). Dimana ZAMP adalah wilayah khusus yang jaringan distribusi terisolasi dan dirancang sebagai wilayah air siap minum. ZAMP merupakan wilayah yang diutamakan pelayanannya oleh PDAM Intan Banjar selama 24 jam. Tingkat kehilangan air ZAMP hingga April 2016 sebesar 31%, yang dimana  telah  melebihi standar tingkat kehilangan air minimum yaitu 20%. Beraasarkan data Hubungan Langganan, adanya pengaduan pelanggan masalah  pipa bocor dan masalah kurangnya tekanan pada jam puncak yang tercatat dari hasil data pressure recorder yang dipasang oleh pihak PDAM pada beberapa titik pantau ZAMP. Tujuan penelitian ini adalah mengidentifikasi sistem jaringan distribusi air minum, kemudian mengevaluasi dan memetakan pola sebaran tekanan pada jaringan distribusi ZAMP serta membandingan hasil simulasi dengan kondisi eksisting. Berdasarkan hasil pengolahan data, jam puncak ZAMP terjadi pukul 07.00 dan jam terendah terjadi pada  pukul  04.00. Berdasarkan hasil simulasi Epanet 2.0, terdapat 3 node yang memiliki tekanan <10 m. Hal ini dapat disebabkan karena adanya perbedaan elevasi, jarak yang semkin menjauhi sumber air, dan ketidaksesuaian dimensi pipa. Kata kunci: Epanet 2.0, sistem jaringan distribusi, tekanan, ZAMP. PDAM Intan Banjar has a program to improve the water quality, which is called as Zona Air Minum Prima (ZAMP), where ZAMP is a special isolated distribution network area designed as a potable water. ZAMP is an area served priority by PDAM Intan Banjar for 24 hours. ZAMP’s water loss rate in April 2016 was 31%, it exceeded the minimum standard rate of water loss, 20%. The existence of customer complaints about leaking pipes and lack of pressure at peak hours were recorded from pressure recorder data result that was set at some ZMAP critical points. The purpose of this study is to identify the system of water distribution networks, evaluate and map the distribution pattern of the pressure of water distribution networks, as well as to compare the simulation results with today’s condition. Besade on data processing result, ZAMP’s peak hour occurred at 07.00 and its lowest occurred at 04.00 o’clock. Based on Epanet 2.0’s simulation results, there existed 3 nodes that have pressure <10m. These can be due to the differences in elevation, increasing distance from the source water, and the mismatching in pipe dimensions. Keywords:, distribution network system, Epanet 2.0, pressure, ZAMP.
Center for Journal Management and Publication, Lambung Mangkurat University
Title: EVALUASI TEKANAN JARINGAN DISTRIBUSI ZONA AIR MINUM PRIMA (ZAMP) PDAM INTAN BANJAR MENGGUNAKAN EPANET 2.0
Description:
PDAM Intan Banjar melakukan sebuah program untuk meningkatkan kualitas Air Minum yang disebut Zona Air Minum Prima (ZAMP).
Dimana ZAMP adalah wilayah khusus yang jaringan distribusi terisolasi dan dirancang sebagai wilayah air siap minum.
ZAMP merupakan wilayah yang diutamakan pelayanannya oleh PDAM Intan Banjar selama 24 jam.
Tingkat kehilangan air ZAMP hingga April 2016 sebesar 31%, yang dimana  telah  melebihi standar tingkat kehilangan air minimum yaitu 20%.
Beraasarkan data Hubungan Langganan, adanya pengaduan pelanggan masalah  pipa bocor dan masalah kurangnya tekanan pada jam puncak yang tercatat dari hasil data pressure recorder yang dipasang oleh pihak PDAM pada beberapa titik pantau ZAMP.
Tujuan penelitian ini adalah mengidentifikasi sistem jaringan distribusi air minum, kemudian mengevaluasi dan memetakan pola sebaran tekanan pada jaringan distribusi ZAMP serta membandingan hasil simulasi dengan kondisi eksisting.
Berdasarkan hasil pengolahan data, jam puncak ZAMP terjadi pukul 07.
00 dan jam terendah terjadi pada  pukul  04.
00.
Berdasarkan hasil simulasi Epanet 2.
0, terdapat 3 node yang memiliki tekanan <10 m.
Hal ini dapat disebabkan karena adanya perbedaan elevasi, jarak yang semkin menjauhi sumber air, dan ketidaksesuaian dimensi pipa.
 Kata kunci: Epanet 2.
0, sistem jaringan distribusi, tekanan, ZAMP.
 PDAM Intan Banjar has a program to improve the water quality, which is called as Zona Air Minum Prima (ZAMP), where ZAMP is a special isolated distribution network area designed as a potable water.
ZAMP is an area served priority by PDAM Intan Banjar for 24 hours.
ZAMP’s water loss rate in April 2016 was 31%, it exceeded the minimum standard rate of water loss, 20%.
The existence of customer complaints about leaking pipes and lack of pressure at peak hours were recorded from pressure recorder data result that was set at some ZMAP critical points.
The purpose of this study is to identify the system of water distribution networks, evaluate and map the distribution pattern of the pressure of water distribution networks, as well as to compare the simulation results with today’s condition.
Besade on data processing result, ZAMP’s peak hour occurred at 07.
00 and its lowest occurred at 04.
00 o’clock.
Based on Epanet 2.
0’s simulation results, there existed 3 nodes that have pressure <10m.
These can be due to the differences in elevation, increasing distance from the source water, and the mismatching in pipe dimensions.
 Keywords:, distribution network system, Epanet 2.
0, pressure, ZAMP.

Related Results

Pengaruh Kualitas Pelayanan PDAM, Tarif PDAM dan Tempat Pembayaran PDAM terhadap Penerimaan Pembayaraan PDAM
Pengaruh Kualitas Pelayanan PDAM, Tarif PDAM dan Tempat Pembayaran PDAM terhadap Penerimaan Pembayaraan PDAM
This study aims to find out and test the influence of PDAM service quality, PDAM tariff and PDAM payment place on PDAM payment receipts. This research was conducted with a quantita...
PERENCANAAN DAN PERANCANGAN GEDUNG BALE BANJAR BUALU KELURAHAN BENOA, KABUPATEN BADUNG
PERENCANAAN DAN PERANCANGAN GEDUNG BALE BANJAR BUALU KELURAHAN BENOA, KABUPATEN BADUNG
Banjar Bualu didirikan sekitar tahun 1905 dan merupakan banjar pertama yang dibentuk di kawasan Desa Adat Bualu. Terdapat 8 banjar yang ada di wilayah Desa Adat Bualu, nama-nama Ba...
The Public Relations In Handling The Complaints
The Public Relations In Handling The Complaints
Abstract. The role of public relations in handling the complaints to rising water rate PDAM aims to build the emotional and build a proper relationship with the community kabupaten...
STUDI PERENCANAAN PENGEMBANGAN JARINGAN PERPIPAAN DISTRIBUSI AIR MINUM DI KECAMATAN MELAK, KABUPATEN KUTAI BARAT
STUDI PERENCANAAN PENGEMBANGAN JARINGAN PERPIPAAN DISTRIBUSI AIR MINUM DI KECAMATAN MELAK, KABUPATEN KUTAI BARAT
Penyediaan air bersih merupakan salah satu kebutuhan dasar dan hak sosial ekonomi masyarakat yang harus dipenuhi oleh Pemerintah Daerah maupun Pemerintah Pusat. PDAM Kabupaten Kuta...
FAKTOR DOMINAN DAN STRATEGI PENYEDIAAN AIR BERSIH DI DESA RAWAN AIR BERSIH PADA KECAMATAN BAITUSSALAM KABUPATEN ACEH BESAR
FAKTOR DOMINAN DAN STRATEGI PENYEDIAAN AIR BERSIH DI DESA RAWAN AIR BERSIH PADA KECAMATAN BAITUSSALAM KABUPATEN ACEH BESAR
Abstract: Baitussalam sub-district is one of the areas vulnerable to water in the district of Aceh Besar. During this time the District community Baitussalam it difficult to obtain...
EVALUASI DAN PENINGKATAN KINERJA JARINGAN PIPA DISTRIBUSI AIR BERSIH DI IPA III PDAM INTAN BANJAR KECAMATAN SIMPANG EMPAT
EVALUASI DAN PENINGKATAN KINERJA JARINGAN PIPA DISTRIBUSI AIR BERSIH DI IPA III PDAM INTAN BANJAR KECAMATAN SIMPANG EMPAT
Pada jaringan distribusi Kecamatan Simpang Empat, air bersih di distribusikan oleh PDAM Intan Banjar. Air bersih tersebut didistribusikan melalui IPA III Simpang Empat. Dalam pendi...
POTENSI PENGGUNAAN IPAL DAN SPAH UNTUK MENGHEMAT PENGGUNAAN AIR PDAM PADA MAL
POTENSI PENGGUNAAN IPAL DAN SPAH UNTUK MENGHEMAT PENGGUNAAN AIR PDAM PADA MAL
A shopping centre produces domestic wastewater every day. This domestic wastewater consists of blackwater (toilet) wastewater and greywater (household) wastewater. Wastewater gener...
RANCANG BANGUN SISTEM PEMANTAUAN KONDISI AIR
RANCANG BANGUN SISTEM PEMANTAUAN KONDISI AIR
The limited number of water condition monitoring officers at the Bone Bolango PDAM water reservoir has caused many customer complaints about the turbidity and sometimes non-flowing...

Back to Top