Different material properties of cancellous bone influence analysis of glenoid component loosening: A finite element study
View through CrossRef
Glenoid component loosening is one of common complications after total shoulder arthroplasty. In investigating the glenoid component loosening, the finite element study is one of methods that have been utilised by experts. Therefore, assigning material properties for all finite element models become crucial to avoid any misinterpretation which, later, lead to wrong prediction on the performance of glenoid implant. This study was conducted to achieve two objectives; (1) to analyse the effect of different bone properties towards micromotion and stress at implant and cement, and (2) to clarify simplification of bone properties in evaluating glenoid component loosening. A load of 750N was simulated at three different glenoid locations (centre – C, superior-anterior-SA, superior-posterior-SP) which imitate concentric and eccentric loadings for elderly people daily activities. Our result showed that large different in micromotion and stress at implant between orthotropic model and another two model (isotropic and full cortical) does not allow simplification for assigning material properties for bone. Thus, assigning cancellous bone as orthotropic material was a realistic material property to represent the real bone condition in evaluating glenoid implant loosening.
Title: Different material properties of cancellous bone influence analysis of glenoid component loosening: A finite element study
Description:
Glenoid component loosening is one of common complications after total shoulder arthroplasty.
In investigating the glenoid component loosening, the finite element study is one of methods that have been utilised by experts.
Therefore, assigning material properties for all finite element models become crucial to avoid any misinterpretation which, later, lead to wrong prediction on the performance of glenoid implant.
This study was conducted to achieve two objectives; (1) to analyse the effect of different bone properties towards micromotion and stress at implant and cement, and (2) to clarify simplification of bone properties in evaluating glenoid component loosening.
A load of 750N was simulated at three different glenoid locations (centre – C, superior-anterior-SA, superior-posterior-SP) which imitate concentric and eccentric loadings for elderly people daily activities.
Our result showed that large different in micromotion and stress at implant between orthotropic model and another two model (isotropic and full cortical) does not allow simplification for assigning material properties for bone.
Thus, assigning cancellous bone as orthotropic material was a realistic material property to represent the real bone condition in evaluating glenoid implant loosening.
Related Results
Morphometric analysis of glenoid cavity in adult human scapulae and its clinical importance
Morphometric analysis of glenoid cavity in adult human scapulae and its clinical importance
Background: The glenoid cavity of scapula is quite small, which allows space for only limited fixation devices. Appropriate fixation of the glenoid component of shoulder is of key ...
Morphometric analysis of cavitas glenoidalis with multidedector CT
Morphometric analysis of cavitas glenoidalis with multidedector CT
The glenoid cavity is a sliced egg-shaped joint surface located on the lateral margin of the scapula to form the shoulder joint. Recognition of variations in shape and dimensions o...
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Objectives: Bone morphogenetic proteins (BMPs) belong to the transforming growth factor superfamily that were first discovered by Marshall Urist. There are 14 BMPs identified to da...
Time-dependent behaviour of bone accentuates loosening in the fixation of fractures using bone-screw systems
Time-dependent behaviour of bone accentuates loosening in the fixation of fractures using bone-screw systems
AimsLoosening is a well-known complication in the fixation of fractures using devices such as locking plates or unilateral fixators. It is believed that high strains in the bone at...
Morphological Analysis of Glenoid Cavity of Scapula in Bihar Population
Morphological Analysis of Glenoid Cavity of Scapula in Bihar Population
Background: The glenoid cavity of the scapula forms the socket component of the shoulder joint and is a critical anatomical structure for maintaining shoulder stability and functio...
Is the Walch B3 glenoid significantly worse than the B2?
Is the Walch B3 glenoid significantly worse than the B2?
Background The Walch B3 glenoid is theorized to be a progression of the B2 biconcave pattern. The present study aimed to compare glenoid indices between B2 and B3 patterns. We hypo...
Glenoid fossa position in skeletal class-II malocclusion due to retrognathic mandible and skeletal class-I malocclusion in Pakistani population
Glenoid fossa position in skeletal class-II malocclusion due to retrognathic mandible and skeletal class-I malocclusion in Pakistani population
BACKGROUND & OBJECTIVE: Different dental and skeletal abnormalities interact with each other to cause multiple malocclusions of various areas of the dentofacial region. Associa...
Bone formation in rabbit cancellous bone explant culture model is enhanced by mechanical load
Bone formation in rabbit cancellous bone explant culture model is enhanced by mechanical load
Abstract
Background
When studying and designing an artificial bone in vitro with similar features and functionality of natural bone by tissue eng...