Javascript must be enabled to continue!
Time-dependent behaviour of bone accentuates loosening in the fixation of fractures using bone-screw systems
View through CrossRef
AimsLoosening is a well-known complication in the fixation of fractures using devices such as locking plates or unilateral fixators. It is believed that high strains in the bone at the bone-screw interface can initiate loosening, which can result in infection, and further loosening. Here, we present a new theory of loosening of implants. The time-dependent response of bone subjected to loads results in interfacial deformations in the bone which accumulate with cyclical loading and thus accentuates loosening.MethodsWe used an ‘ideal’ bone-screw system, in which the screw is subjected to cyclical lateral loads and trabecular bone is modelled as non-linear viscoelastic and non-linear viscoelastic-viscoplastic material, based on recent experiments, which we conducted.ResultsWe found that the interfacial deformation in the bone increases with the number of cycles, and the use of a non-linear viscoelastic-viscoplastic model results in larger deformations, some of which are irrecoverable. There is an apparent trend in which interfacial deformations increase with increasing porosity of bone.ConclusionThe developed time-dependent model of the mechanical behaviour of bone permits prediction of loosening due to cyclical loads, which has not been possible previously. Application of this model shows that implant loosening will be accentuated by cyclical loading due to physiological activities, and the risks of loosening are greater in osteoporotic patients. Cite this article: S. Xie, K. Manda, P. Pankaj. Time-dependent behaviour of bone accentuates loosening in the fixation of fractures using bone-screw systems. Bone Joint Res 2018;7:580–586. DOI: 10.1302/2046-3758.710.BJR-2018-0085.R1.
British Editorial Society of Bone & Joint Surgery
Title: Time-dependent behaviour of bone accentuates loosening in the fixation of fractures using bone-screw systems
Description:
AimsLoosening is a well-known complication in the fixation of fractures using devices such as locking plates or unilateral fixators.
It is believed that high strains in the bone at the bone-screw interface can initiate loosening, which can result in infection, and further loosening.
Here, we present a new theory of loosening of implants.
The time-dependent response of bone subjected to loads results in interfacial deformations in the bone which accumulate with cyclical loading and thus accentuates loosening.
MethodsWe used an ‘ideal’ bone-screw system, in which the screw is subjected to cyclical lateral loads and trabecular bone is modelled as non-linear viscoelastic and non-linear viscoelastic-viscoplastic material, based on recent experiments, which we conducted.
ResultsWe found that the interfacial deformation in the bone increases with the number of cycles, and the use of a non-linear viscoelastic-viscoplastic model results in larger deformations, some of which are irrecoverable.
There is an apparent trend in which interfacial deformations increase with increasing porosity of bone.
ConclusionThe developed time-dependent model of the mechanical behaviour of bone permits prediction of loosening due to cyclical loads, which has not been possible previously.
Application of this model shows that implant loosening will be accentuated by cyclical loading due to physiological activities, and the risks of loosening are greater in osteoporotic patients.
Cite this article: S.
Xie, K.
Manda, P.
Pankaj.
Time-dependent behaviour of bone accentuates loosening in the fixation of fractures using bone-screw systems.
Bone Joint Res 2018;7:580–586.
DOI: 10.
1302/2046-3758.
710.
BJR-2018-0085.
R1.
Related Results
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Enhanced Fixation in Sacral Fragility Fractures: The Role of the Transsacral Bar in Preventing Screw Loosening
Enhanced Fixation in Sacral Fragility Fractures: The Role of the Transsacral Bar in Preventing Screw Loosening
Abstract
Purpose
Mechanical failure after minimally invasive posterior pelvic fixation remains a major challenge in elderly patients with sacral fragility fractures...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Comparison of posterior open screw fixation with percutaneous fixation among traumatic thoracolumbar fracture patients.
Comparison of posterior open screw fixation with percutaneous fixation among traumatic thoracolumbar fracture patients.
Objectives: To compare outcome and adverse events of open posterior pedicle screw fixation with percutaneous posterior pedicle screw fixation among patients suffering traumatic tho...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference.
Abstract
Fractures are ubiquitous st...
Single- vs. Dual-Screw Fixation of First MTH in MICA for Hallux Valgus Correction: A Retrospective Comparative Case Series
Single- vs. Dual-Screw Fixation of First MTH in MICA for Hallux Valgus Correction: A Retrospective Comparative Case Series
Background: The optimal fixation strategy for hallux valgus correction using the Minimally Invasive Chevron and Akin (MICA) procedure remains debated despite ongoing advances and a...
Lisfranc open reduction and internal fixation in an athletic population: screw versus suture button fixation
Lisfranc open reduction and internal fixation in an athletic population: screw versus suture button fixation
Background:
Primarily ligamentous Lisfranc injuries occur in athletic populations. Unstable Lisfranc injuries are treated with internal fixation or arthrodesis. Interna...
Biomechanical Comparison of Lag Screw versus Self-Drilling Screw Fixation of Oblique Metatarsal Osteotomy
Biomechanical Comparison of Lag Screw versus Self-Drilling Screw Fixation of Oblique Metatarsal Osteotomy
Background: Several fixation methods for a Weil metatarsal osteotomy have been proposed. Lag screw fixation has been described as the preferred fixation technique. The self-drillin...

