Fitness-Tracker Assisted Frailty-Assessment Before Transcatheter Aortic Valve Implantation: Proof-of-Concept Study (Preprint)
View through CrossRef
BACKGROUND
While transcatheter aortic valve replacement (TAVR) has revolutionized the treatment of aortic valve stenosis, wearable health-monitoring devices are gradually transforming digital patient care.
OBJECTIVE
The aim of this study was to develop a simple, efficient, and economical method for preprocedural frailty assessment based on parameters measured by a wearable health-monitoring device.
METHODS
In this prospective study, we analyzed data of 50 consecutive patients with mean (SD) age of 77.5 (5.1) years and a median (IQR) European system for cardiac operative risk evaluation (EuroSCORE) II of 3.3 (4.1) undergoing either transfemoral or transapical TAVR between 2017 and 2018. Every patient was fitted with a wrist-worn health-monitoring device (Garmin Vivosmart 3) for 1 week prior to the procedure. Twenty different parameters were measured, and threshold levels for the 3 most predictive categories (ie, step count, heart rate, and preprocedural stress) were calculated. Patients were assigned 1 point per category for exceeding the cut-off value and were then classified into 4 stages (no, borderline, moderate, and severe frailty). Furthermore, the FItness-tracker assisted Frailty-Assessment Score (FIFA score) was compared with the scores of the preprocedural gait speed category derived from the 6-minute walk test (GSC-6MWT) and the Edmonton Frail Scale classification (EFS-C). The primary study endpoint was hospital mortality.
RESULTS
The overall preprocedural stress level (<i>P=.</i>02), minutes of high stress per day (<i>P=.</i>02), minutes of rest per day (<i>P=.</i>045), and daily heart rate maximum (<i>P=.</i>048) as single parameters were the strongest predictors of hospital mortality. When comparing the different frailty scores, the FIFA score demonstrated the greatest predictive power for hospital mortality (FIFA area under the curve [AUC] 0.844, CI 0.656-1.000; <i>P=.</i>048; GSC-6MWT AUC 0.671, CI 0.487-0.855; <i>P=.</i>42; EFS-C AUC 0.636, CI 0.254-1.000; <i>P=.</i>44).
CONCLUSIONS
This proof-of-concept study demonstrates the strong predictive performance of the FIFA score compared to that of the conventional frailty assessments.
Title: Fitness-Tracker Assisted Frailty-Assessment Before Transcatheter Aortic Valve Implantation: Proof-of-Concept Study (Preprint)
Description:
BACKGROUND
While transcatheter aortic valve replacement (TAVR) has revolutionized the treatment of aortic valve stenosis, wearable health-monitoring devices are gradually transforming digital patient care.
OBJECTIVE
The aim of this study was to develop a simple, efficient, and economical method for preprocedural frailty assessment based on parameters measured by a wearable health-monitoring device.
METHODS
In this prospective study, we analyzed data of 50 consecutive patients with mean (SD) age of 77.
5 (5.
1) years and a median (IQR) European system for cardiac operative risk evaluation (EuroSCORE) II of 3.
3 (4.
1) undergoing either transfemoral or transapical TAVR between 2017 and 2018.
Every patient was fitted with a wrist-worn health-monitoring device (Garmin Vivosmart 3) for 1 week prior to the procedure.
Twenty different parameters were measured, and threshold levels for the 3 most predictive categories (ie, step count, heart rate, and preprocedural stress) were calculated.
Patients were assigned 1 point per category for exceeding the cut-off value and were then classified into 4 stages (no, borderline, moderate, and severe frailty).
Furthermore, the FItness-tracker assisted Frailty-Assessment Score (FIFA score) was compared with the scores of the preprocedural gait speed category derived from the 6-minute walk test (GSC-6MWT) and the Edmonton Frail Scale classification (EFS-C).
The primary study endpoint was hospital mortality.
RESULTS
The overall preprocedural stress level (<i>P=.
</i>02), minutes of high stress per day (<i>P=.
</i>02), minutes of rest per day (<i>P=.
</i>045), and daily heart rate maximum (<i>P=.
</i>048) as single parameters were the strongest predictors of hospital mortality.
When comparing the different frailty scores, the FIFA score demonstrated the greatest predictive power for hospital mortality (FIFA area under the curve [AUC] 0.
844, CI 0.
656-1.
000; <i>P=.
</i>048; GSC-6MWT AUC 0.
671, CI 0.
487-0.
855; <i>P=.
</i>42; EFS-C AUC 0.
636, CI 0.
254-1.
000; <i>P=.
</i>44).
CONCLUSIONS
This proof-of-concept study demonstrates the strong predictive performance of the FIFA score compared to that of the conventional frailty assessments.
Related Results
Incidence, predictors and outcomes of Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR): a systematic review and meta-analysis
Incidence, predictors and outcomes of Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR): a systematic review and meta-analysis
Abstract
Background
Surgical aortic valve replacement has been the treatment of choice for patients with aortic valve disease be...
Fitness-Tracker Assisted Frailty-Assessment Before Transcatheter Aortic Valve Implantation: Proof-of-Concept Study
Fitness-Tracker Assisted Frailty-Assessment Before Transcatheter Aortic Valve Implantation: Proof-of-Concept Study
Background
While transcatheter aortic valve replacement (TAVR) has revolutionized the treatment of aortic valve stenosis, wearable health-monitoring devices are...
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
Objectives
To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia.
...
Small Aortic Annulus: Aortic Allografts vs Perceval S
Small Aortic Annulus: Aortic Allografts vs Perceval S
Цель. Оценить и сравнить гемодинамические показатели и изменение качества жизни после имплантации протезов Perceval S и аортальных аллографтов, а также частоту и спектр осложнений ...
Loneliness as a risk factor for frailty transition among Chinese old people
Loneliness as a risk factor for frailty transition among Chinese old people
Abstract
Background: loneliness has been observed to be associated with subsequent adverse outcomes. Our study aims to investigate whether and how loneliness is related to ...
Prevalence and factors associated with frailty in older adults from the Kenyan coast
Prevalence and factors associated with frailty in older adults from the Kenyan coast
Abstract
Background: The burden and determinants of frailty in sub-Saharan Africa (SSA) are largely unknown despite a rapidly aging population in the region. To address the...
The introduction and impact of a National Frailty Education Programme
The introduction and impact of a National Frailty Education Programme
Background: Frailty is a dynamic functional state. Its onset and progression can be reduced and even reversed, if early intervention and correct management strategies are set in pl...
Valve-Sparing Aortic Root Replacement by Congenital Heart Surgeons: A Single Center Experience.
Valve-Sparing Aortic Root Replacement by Congenital Heart Surgeons: A Single Center Experience.
Background Aortic root dilatation and aortic insufficiency can
occur in patients with prior conotruncal defect surgery, the Ross
procedure, and connective tissue disease (CTD). Val...