ADAPT system is a dramatic advance in computer-assisted surgery for femoral trochanteric fractures
View through CrossRef
Introduction: In recent years, computer-assisted surgery has made it possible to undergo surgery with a high degree of precision. This study aimed to investigate the usefulness of computer-assisted surgery for femoral trochanteric fractures using the ADAPT (ADAptive Positioning Technology) system. Methods: A total of forty patients with femoral trochanteric fracture underwent intramedullary nailing for fracture fixation: in twenty patients, the ADAPT system (ADAPT group), and in the other twenty, it was not used (control group). The operative time, intraoperative fluoroscopy time, tip apex distance (TAD), and tip to head surface distance (TSD) were measured and compared between the two groups to assess the efficiency and accuracy of the surgery. Results: The operative time was significantly shorter (P < 0.05), intraoperative fluoroscopy time was significantly reduced (P < 0.01), and implant placement was significantly better in the ADAPT group (P < 0.01). Conclusion: Navigation systems have been developed to improve the efficiency of surgery. The ADAPT system was considered a very useful device for intramedullary nailing of femoral trochanteric fractures, as it reduced the intraoperative fluoroscopy time and improved the accuracy of implant placement, also reducing the operative time.
Title: ADAPT system is a dramatic advance in computer-assisted surgery for femoral trochanteric fractures
Description:
Introduction: In recent years, computer-assisted surgery has made it possible to undergo surgery with a high degree of precision.
This study aimed to investigate the usefulness of computer-assisted surgery for femoral trochanteric fractures using the ADAPT (ADAptive Positioning Technology) system.
Methods: A total of forty patients with femoral trochanteric fracture underwent intramedullary nailing for fracture fixation: in twenty patients, the ADAPT system (ADAPT group), and in the other twenty, it was not used (control group).
The operative time, intraoperative fluoroscopy time, tip apex distance (TAD), and tip to head surface distance (TSD) were measured and compared between the two groups to assess the efficiency and accuracy of the surgery.
Results: The operative time was significantly shorter (P < 0.
05), intraoperative fluoroscopy time was significantly reduced (P < 0.
01), and implant placement was significantly better in the ADAPT group (P < 0.
01).
Conclusion: Navigation systems have been developed to improve the efficiency of surgery.
The ADAPT system was considered a very useful device for intramedullary nailing of femoral trochanteric fractures, as it reduced the intraoperative fluoroscopy time and improved the accuracy of implant placement, also reducing the operative time.
Related Results
Medial Calcar Comminution and Intramedullary Nail Failure in Unstable Geriatric Trochanteric Hip Fractures
Medial Calcar Comminution and Intramedullary Nail Failure in Unstable Geriatric Trochanteric Hip Fractures
Background and Objectives: An increasing global burden of geriatric hip fractures is anticipated. The appropriate treatment for fractures is of ongoing interest and becoming more r...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Accompanying Therapy in the Surgical Treatment of Pathological Fractures of the Long Bones and Chronic Fractures of the Trochanteric Region
Accompanying Therapy in the Surgical Treatment of Pathological Fractures of the Long Bones and Chronic Fractures of the Trochanteric Region
The article presents a study of palliative surgical treatment of patients with pathological fractures of the long bones and chronic trochanteric fractures. Those patients are not i...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference.
Abstract
Fractures are ubiquitous st...
Outcome of dynamic hip screw with trochanteric stabilizing plate in treatment of unstable intertrochanteric femoral fractures in elderly patients.
Outcome of dynamic hip screw with trochanteric stabilizing plate in treatment of unstable intertrochanteric femoral fractures in elderly patients.
Objective: To know about the outcome of dynamic hip screw with trochanteric stabilizing plate in treatment of unstable inter-trochanteric femoral fractures in elderly patients. St...
FEMORAL NECK FRACTURES, EPIDEMIOLOGY, ANATOMICAL DESCRIPTION, MECHANISM OF ACTION, CLASSIFICATION, CLINICAL EVALUATION, IMAGING EVALUATION, TREATMENT AND COMPLICATIONS
FEMORAL NECK FRACTURES, EPIDEMIOLOGY, ANATOMICAL DESCRIPTION, MECHANISM OF ACTION, CLASSIFICATION, CLINICAL EVALUATION, IMAGING EVALUATION, TREATMENT AND COMPLICATIONS
Introduction: Femoral neck fractures (FNF) are frequent and devastating injuries in orthopedics and traumatology. It usually has several therapeutic options depending on the type o...
Rigid intramedullary nail fixation of traumatic femoral fractures in the skeletally immature
Rigid intramedullary nail fixation of traumatic femoral fractures in the skeletally immature
Abstract
Objective:
To determine the rate of femoral head osteonecrosis, and other complications following rigid intramedullary (IM) nail fixatio...
Gamma 3 Long Nail for Complex Sub-Trochanteric Fractures: A Ten-Year Retrospective Study
Gamma 3 Long Nail for Complex Sub-Trochanteric Fractures: A Ten-Year Retrospective Study
Cephalomedullary nailing is considered the treatment of choice for trochanteric and subtrochanteric femoral fractures. The aim of this study was to report postoperative outcomes of...