Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

ADAPT system is a dramatic advance in computer-assisted surgery for femoral trochanteric fractures

View through CrossRef
Introduction: In recent years, computer-assisted surgery has made it possible to undergo surgery with a high degree of precision. This study aimed to investigate the usefulness of computer-assisted surgery for femoral trochanteric fractures using the ADAPT (ADAptive Positioning Technology) system. Methods: A total of forty patients with femoral trochanteric fracture underwent intramedullary nailing for fracture fixation: in twenty patients, the ADAPT system (ADAPT group), and in the other twenty, it was not used (control group). The operative time, intraoperative fluoroscopy time, tip apex distance (TAD), and tip to head surface distance (TSD) were measured and compared between the two groups to assess the efficiency and accuracy of the surgery. Results: The operative time was significantly shorter (P < 0.05), intraoperative fluoroscopy time was significantly reduced (P < 0.01), and implant placement was significantly better in the ADAPT group (P < 0.01). Conclusion: Navigation systems have been developed to improve the efficiency of surgery. The ADAPT system was considered a very useful device for intramedullary nailing of femoral trochanteric fractures, as it reduced the intraoperative fluoroscopy time and improved the accuracy of implant placement, also reducing the operative time.
Title: ADAPT system is a dramatic advance in computer-assisted surgery for femoral trochanteric fractures
Description:
Introduction: In recent years, computer-assisted surgery has made it possible to undergo surgery with a high degree of precision.
This study aimed to investigate the usefulness of computer-assisted surgery for femoral trochanteric fractures using the ADAPT (ADAptive Positioning Technology) system.
Methods: A total of forty patients with femoral trochanteric fracture underwent intramedullary nailing for fracture fixation: in twenty patients, the ADAPT system (ADAPT group), and in the other twenty, it was not used (control group).
The operative time, intraoperative fluoroscopy time, tip apex distance (TAD), and tip to head surface distance (TSD) were measured and compared between the two groups to assess the efficiency and accuracy of the surgery.
Results: The operative time was significantly shorter (P < 0.
05), intraoperative fluoroscopy time was significantly reduced (P < 0.
01), and implant placement was significantly better in the ADAPT group (P < 0.
01).
Conclusion: Navigation systems have been developed to improve the efficiency of surgery.
The ADAPT system was considered a very useful device for intramedullary nailing of femoral trochanteric fractures, as it reduced the intraoperative fluoroscopy time and improved the accuracy of implant placement, also reducing the operative time.

Related Results

Medial Calcar Comminution and Intramedullary Nail Failure in Unstable Geriatric Trochanteric Hip Fractures
Medial Calcar Comminution and Intramedullary Nail Failure in Unstable Geriatric Trochanteric Hip Fractures
Background and Objectives: An increasing global burden of geriatric hip fractures is anticipated. The appropriate treatment for fractures is of ongoing interest and becoming more r...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference. Abstract Fractures are ubiquitous st...
Rigid intramedullary nail fixation of traumatic femoral fractures in the skeletally immature
Rigid intramedullary nail fixation of traumatic femoral fractures in the skeletally immature
Abstract Objective: To determine the rate of femoral head osteonecrosis, and other complications following rigid intramedullary (IM) nail fixatio...
Angiographic evaluation of femoral bifurcation in Chinese population
Angiographic evaluation of femoral bifurcation in Chinese population
Objective Common femoral artery (CFA) access has been proved to be safe with lower risk of complications in percutaneous catheterisation. The femoral head can be ...