Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Outcome of dynamic hip screw with trochanteric stabilizing plate in treatment of unstable intertrochanteric femoral fractures in elderly patients.

View through CrossRef
Objective: To know about the outcome of dynamic hip screw with trochanteric stabilizing plate in treatment of unstable inter-trochanteric femoral fractures in elderly patients.  Study Design: Descriptive study. Setting: Maqsood Medical Complex, Pak Medical Centre and Habib Medical Complex. Period: August 2016 to July 2018. Material & Methods: Total of 70 patients with unstable inter-trochanteric fracture and age above 60 years were included in the study. The fracture was fixed with dynamic hip screw and trochanteric stabilizing plate. Patients were evaluated every month after surgery for healing of fracture. Final functional outcome was measured at 6 months after surgery with Harris Hip Score. Results: Out of 70 patients 44 (63%) were females and 26 (37%) were males. Mean age was 74.34(SD + 08.31) years with range of 60 to 87 years. Mean Harris Hip Score at 6 months was 85% with standard deviation of± 4.Ten (14%) patients had excellent, 40 (58%) patients had good, 16 (23%) patients fair and 4 (5%) patients poor functional outcome. Conclusion: Excellent and good functional outcome can be achieved in unstable inter-trochanteric fractures fixed with dynamic hip screw and trochanteric stabilizing plate in majority of patients.
Title: Outcome of dynamic hip screw with trochanteric stabilizing plate in treatment of unstable intertrochanteric femoral fractures in elderly patients.
Description:
Objective: To know about the outcome of dynamic hip screw with trochanteric stabilizing plate in treatment of unstable inter-trochanteric femoral fractures in elderly patients.
 Study Design: Descriptive study.
Setting: Maqsood Medical Complex, Pak Medical Centre and Habib Medical Complex.
Period: August 2016 to July 2018.
Material & Methods: Total of 70 patients with unstable inter-trochanteric fracture and age above 60 years were included in the study.
The fracture was fixed with dynamic hip screw and trochanteric stabilizing plate.
Patients were evaluated every month after surgery for healing of fracture.
Final functional outcome was measured at 6 months after surgery with Harris Hip Score.
Results: Out of 70 patients 44 (63%) were females and 26 (37%) were males.
Mean age was 74.
34(SD + 08.
31) years with range of 60 to 87 years.
Mean Harris Hip Score at 6 months was 85% with standard deviation of± 4.
Ten (14%) patients had excellent, 40 (58%) patients had good, 16 (23%) patients fair and 4 (5%) patients poor functional outcome.
Conclusion: Excellent and good functional outcome can be achieved in unstable inter-trochanteric fractures fixed with dynamic hip screw and trochanteric stabilizing plate in majority of patients.

Related Results

FUNCTIONAL OUTCOMES OF PROXIMAL FEMORAL NAIL VERSUS DYNAMIC HIP SCREW IN INTERTROCHANTERIC FRACTURE OF FEMUR
FUNCTIONAL OUTCOMES OF PROXIMAL FEMORAL NAIL VERSUS DYNAMIC HIP SCREW IN INTERTROCHANTERIC FRACTURE OF FEMUR
Intertrochanteric fractures of the femur represent a significant proportion of hip fractures in the elderly and are associated with considerable morbidity, prolonged rehabilitation...
Intramedullary Nail Versus Dynamic Hip Screw; Intramedullary Nail (Advantages And Disadvantages)
Intramedullary Nail Versus Dynamic Hip Screw; Intramedullary Nail (Advantages And Disadvantages)
since 1950s surgical treatment of extracapsular hip fractures is done using a variety of different implants. Unstable fractures are fractures with lateral wall or posteromedial c...
Comparison of Unstable Per-Trochanteric Fractures Fixed with Proximal Femoral Nail Versus Dynamic Hip Screw Using Harris Hip Score
Comparison of Unstable Per-Trochanteric Fractures Fixed with Proximal Femoral Nail Versus Dynamic Hip Screw Using Harris Hip Score
Objective: To compare the frequency of a good functional outcome in unstable per-trochanteric fractures fixed with a dynamic hip screw and proximal femoral nail using the Harris Hi...
Medial Calcar Comminution and Intramedullary Nail Failure in Unstable Geriatric Trochanteric Hip Fractures
Medial Calcar Comminution and Intramedullary Nail Failure in Unstable Geriatric Trochanteric Hip Fractures
Background and Objectives: An increasing global burden of geriatric hip fractures is anticipated. The appropriate treatment for fractures is of ongoing interest and becoming more r...
Functional Outcome And Mortality Assessment Following Proximal Femoral Nailing In Inter Trochanteric Fracture
Functional Outcome And Mortality Assessment Following Proximal Femoral Nailing In Inter Trochanteric Fracture
Intertrochanteric fractures constitute one of the most typical fractures of the hip. The incidence of fractures in the trochanteric area has risen with an increase in numbers of th...
Physiological and biomechanical factors contributing to the hip adduction angle in female runners
Physiological and biomechanical factors contributing to the hip adduction angle in female runners
Running is a popular form of exercise that is accompanied by many health benefits. However, running also comes with a risk of overuse injuries. Women have a higher risk for overuse...

Back to Top