Javascript must be enabled to continue!
Accuracy of chitotriosidase activity and CCL18 concentration in assessing type I Gaucher disease severity. A systematic review with meta-analysis of individual participant data
View through CrossRef
Chitotriosidase activity and CCL18 concentration are interchangeably used for monitoring Gaucher disease (GD) activity, together with clinical assessment. However, comparative studies of these two biomarkers are scarce and of limited sample size. The aim of this systematic review with meta-analysis of individual participant data (IPD) was to compare the accuracy of chitotriosidase activity and CCL18 concentration for assessing type I GD severity. We identified cross-sectional and prospective cohort studies by searching Medline, EMBASE, and CENTRAL from 1995 to June 2017, and by contacting research groups. The primary outcome was a composite of liver volume >1.25 multiple of normal (MN), spleen volume >5 MN, hemoglobin concentration <11 g/dL, and platelet count <100x109/L. Overall, IPD included 1109 observations from 334 patients enrolled in nine primary studies, after excluding 111 patients with undocumented values and 18 patients with deficient chitotriosidase activity. IPD were unavailable for 14 eligible primary studies. The primary outcome was associated with a 5.3-fold (95% confidence interval [CI], 4.2 to 6.6) and 3.0-fold (95% CI, 2.6 to 3.6) increase of the geometric mean for chitotriosidase activity and CCL18 concentration, respectively. The corresponding areas under the receiver operating characteristics curves were 0.82 and 0.84 (summary difference, 0.02, 95% CI, -0.02 to 0.05). The addition of chitotriosidase activity did not improve the accuracy of CCL18 concentration. Estimates remained robust in the sensitivity analysis and consistent across subgroups. Neither chitotriosidase activity nor CCL18 concentration varied significantly according to a recent history of bone events among 97 patients. In conclusion, CCL18 concentration is as accurate as chitotriosidase activity in assessing hematological and visceral parameters of GD severity and can be measured in all GD patients. This meta-analysis supports the use of CCL18 rather than chitotriosidase activity for monitoring GD activity in routine practice.
Ferrata Storti Foundation (Haematologica)
Title: Accuracy of chitotriosidase activity and CCL18 concentration in assessing type I Gaucher disease severity. A systematic review with meta-analysis of individual participant data
Description:
Chitotriosidase activity and CCL18 concentration are interchangeably used for monitoring Gaucher disease (GD) activity, together with clinical assessment.
However, comparative studies of these two biomarkers are scarce and of limited sample size.
The aim of this systematic review with meta-analysis of individual participant data (IPD) was to compare the accuracy of chitotriosidase activity and CCL18 concentration for assessing type I GD severity.
We identified cross-sectional and prospective cohort studies by searching Medline, EMBASE, and CENTRAL from 1995 to June 2017, and by contacting research groups.
The primary outcome was a composite of liver volume >1.
25 multiple of normal (MN), spleen volume >5 MN, hemoglobin concentration <11 g/dL, and platelet count <100x109/L.
Overall, IPD included 1109 observations from 334 patients enrolled in nine primary studies, after excluding 111 patients with undocumented values and 18 patients with deficient chitotriosidase activity.
IPD were unavailable for 14 eligible primary studies.
The primary outcome was associated with a 5.
3-fold (95% confidence interval [CI], 4.
2 to 6.
6) and 3.
0-fold (95% CI, 2.
6 to 3.
6) increase of the geometric mean for chitotriosidase activity and CCL18 concentration, respectively.
The corresponding areas under the receiver operating characteristics curves were 0.
82 and 0.
84 (summary difference, 0.
02, 95% CI, -0.
02 to 0.
05).
The addition of chitotriosidase activity did not improve the accuracy of CCL18 concentration.
Estimates remained robust in the sensitivity analysis and consistent across subgroups.
Neither chitotriosidase activity nor CCL18 concentration varied significantly according to a recent history of bone events among 97 patients.
In conclusion, CCL18 concentration is as accurate as chitotriosidase activity in assessing hematological and visceral parameters of GD severity and can be measured in all GD patients.
This meta-analysis supports the use of CCL18 rather than chitotriosidase activity for monitoring GD activity in routine practice.
Related Results
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract
The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical activi...
CCL18 et réponse régulatrice, de la situation physiologique à l'atopie
CCL18 et réponse régulatrice, de la situation physiologique à l'atopie
Les chimiokines sont un élément essentiel du trafic cellulaire aussi bien homéostatique que dans des situations pathologiques. Outre cette fonction chimiotactique spécifique à ce t...
CCL18 — Potential Biomarker of Fibroinflammatory Activity in Chronic Periaortitis
CCL18 — Potential Biomarker of Fibroinflammatory Activity in Chronic Periaortitis
Objective.Promising therapeutic approaches have emerged in chronic periaortitis, whereas peripheral blood biomarkers are lacking. CC-chemokine ligand 18 (CCL18) is known as a marke...
Effect of interferon-γ, interleukin-10, lipopolysaccharide and tumor necrosis factor-α on chitotriosidase synthesis in human macrophages
Effect of interferon-γ, interleukin-10, lipopolysaccharide and tumor necrosis factor-α on chitotriosidase synthesis in human macrophages
AbstractHuman chitotriosidase is a chitinolytic enzyme and mainly produced by activated macrophages. Recently, we observed that prolactin, which is structurally related to several ...
Human Chitotriosidase: A Potential New Marker of Sarcoidosis Severity
Human Chitotriosidase: A Potential New Marker of Sarcoidosis Severity
Sarcoidosis is a multisystemic granulomatous disorder of unknown etiology. The unpredictable clinical course of the disease has prompted research into biomarkers useful for predict...
Chitotriosidase: A sensitive biomarker of sarcoidosis
Chitotriosidase: A sensitive biomarker of sarcoidosis
Chitotriosidase is a member of family of glycosylhydrolases, enzymes involved in the degradation of chitin and chitin-like substrate, identified in a wide variety of organisms. Inc...
Viral respiratory tract infection in Gaucher disease, a rare disease: A case study of 24 patients in Malatya-Turkey
Viral respiratory tract infection in Gaucher disease, a rare disease: A case study of 24 patients in Malatya-Turkey
People with chronic diseases have a higher rate of morbidity and mortality from SARS-CoV-2 infection. A rare lysosomal storage disease is Gaucher disease. Chronic myeloid cell immu...
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract
Introduction
Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...

