Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Power Transformer Wire Estimate

View through CrossRef
This experimental study determined the weight of wire used in power supply using the laboratory technique and procedure to gather data. There were two designs with three treatments each, prepared and subjected to using the Two Way Analysis of Variance. The treatments for the first design were: one is 1 1/8 inch by 1 1/8 inch area and output voltage of 6 volts; two is 1 1/8 inch by 1 1/8 inch area and output voltage of 36 volts; three is 1 1/8 inch by 1 1/8 inch area and output voltage of 110 volts. The treatments for design number two were: one is 1/2 inch by 1/2 inch area and output voltage of 12 volts; two is 3/4 inch by 3/4 inch area and output voltage of 12 volts; three is 1 inch by 1 inch area and output voltage of 12 volts. The test result of significant differences in the effectiveness, efficiency and performance of the different treatments showed no significant difference on windings, temperature, voltage, size of the iron core, current, power, number of turns, turns per volt and force applied in winding.
Title: Power Transformer Wire Estimate
Description:
This experimental study determined the weight of wire used in power supply using the laboratory technique and procedure to gather data.
There were two designs with three treatments each, prepared and subjected to using the Two Way Analysis of Variance.
The treatments for the first design were: one is 1 1/8 inch by 1 1/8 inch area and output voltage of 6 volts; two is 1 1/8 inch by 1 1/8 inch area and output voltage of 36 volts; three is 1 1/8 inch by 1 1/8 inch area and output voltage of 110 volts.
The treatments for design number two were: one is 1/2 inch by 1/2 inch area and output voltage of 12 volts; two is 3/4 inch by 3/4 inch area and output voltage of 12 volts; three is 1 inch by 1 inch area and output voltage of 12 volts.
The test result of significant differences in the effectiveness, efficiency and performance of the different treatments showed no significant difference on windings, temperature, voltage, size of the iron core, current, power, number of turns, turns per volt and force applied in winding.

Related Results

Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
High frequency modeling of power transformers under transients
High frequency modeling of power transformers under transients
This thesis presents the results related to high frequency modeling of power transformers. First, a 25kVA distribution transformer under lightning surges is tested in the laborator...
Numerical simulation of wire temperature field for prediction of wire transfer stability in laser hot wire welding
Numerical simulation of wire temperature field for prediction of wire transfer stability in laser hot wire welding
With preheating wire by resistance heat, laser hot wire welding improves process stability and wire deposition efficiency, which gives broad potential applications in surfacing and...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...
PLC Based Load Sharing of Transformers
PLC Based Load Sharing of Transformers
The transformer is very expensive and bulky power system equipment. It runs and feed the load for 24 hours a day. Sometimes the load on the transformer unexpectedly rises above its...
Simulation modeling study on short circuit ability of distribution transformer
Simulation modeling study on short circuit ability of distribution transformer
Abstract Under short circuit condition, the oil immersed distribution transformer will endure combined electro-thermal stress, eventually lead to the mechanical dama...
Power Transformer Fault Diagnosis System Based on Internet of Things
Power Transformer Fault Diagnosis System Based on Internet of Things
Abstract Transformer is the most important equipment in the power system. The research and development of fault diagnosis technology for Internet of things equipment can ef...