Fetal Doppler Simulator Based on Arduino
View through CrossRef
Heart rate of the fetal is the main indicator of the fetal life in the womb. Monitoring fetal heart rate can’t be done, so a tool is needed to monitoring fetal heart rate. Fetal heart rate can be monitored with fetal doppler. To test the accuracy of Fetal Doppler, a calibration is needed with the Fetal Doppler Simulator. This tool will simulate the fetal heart rate with a BPM value that can be adjusted according to the settings on the device. This module using Arduino as the brain system. On the module there is a selection of BPM from 60 to 240 BPM with an increase of 30 BPM displayed on 2x16 character LCDs. Based on BPM measurement 6 times using Fetal Doppler, the measurement error in a BPM of 60 to BPM 210 is 0%, while at BPM 240 an error is 0.2%. This module has been compared with the standard devices (Fetal Simulator Brand Fluke Biomedical Ps320), the results of the comparison modules with the comparison tool has the same error value in 240 BPM is 0.2% and in BPM 210 there is a difference in the result of module Fetal Doppler reading of 210 BPM while in the comparison tool is 209 BPM. Of the measurement data and analysis, it can be concluded that the tool can work and the tool has the same accuracy as the standard device.
Title: Fetal Doppler Simulator Based on Arduino
Description:
Heart rate of the fetal is the main indicator of the fetal life in the womb.
Monitoring fetal heart rate can’t be done, so a tool is needed to monitoring fetal heart rate.
Fetal heart rate can be monitored with fetal doppler.
To test the accuracy of Fetal Doppler, a calibration is needed with the Fetal Doppler Simulator.
This tool will simulate the fetal heart rate with a BPM value that can be adjusted according to the settings on the device.
This module using Arduino as the brain system.
On the module there is a selection of BPM from 60 to 240 BPM with an increase of 30 BPM displayed on 2x16 character LCDs.
Based on BPM measurement 6 times using Fetal Doppler, the measurement error in a BPM of 60 to BPM 210 is 0%, while at BPM 240 an error is 0.
2%.
This module has been compared with the standard devices (Fetal Simulator Brand Fluke Biomedical Ps320), the results of the comparison modules with the comparison tool has the same error value in 240 BPM is 0.
2% and in BPM 210 there is a difference in the result of module Fetal Doppler reading of 210 BPM while in the comparison tool is 209 BPM.
Of the measurement data and analysis, it can be concluded that the tool can work and the tool has the same accuracy as the standard device.
Related Results
Rancang Bangun Fetal Doppler Simulator untuk Kalibrasi Fetal Doppler
Rancang Bangun Fetal Doppler Simulator untuk Kalibrasi Fetal Doppler
The Fetal Doppler Simulator for calibration is a device designed to ensure the accuracy and reliability of Fetal Doppler equipment in monitoring fetal heart rate. Traditionally, ca...
Global Policy and Practice for Intrauterine Fetal Resuscitation During Fetal Surgery for Open Spina Bifida Repair
Global Policy and Practice for Intrauterine Fetal Resuscitation During Fetal Surgery for Open Spina Bifida Repair
ImportanceGlobally accepted recommendations suggest that a woman should be between 19 weeks and 25 weeks plus 6 days of pregnancy to be considered eligible for fetal closure of ope...
Fetal Arrhythmias: A Clinical Review
Fetal Arrhythmias: A Clinical Review
ABSTRACT
Fetal rhythm abnormalities occur in 2% of pregnancies. They are usually identified by the obstetrician or midwifes after 20 weeks. There are four different methods used to...
Perancangan dan Pembuatan Fetal Doppler Simulator
Perancangan dan Pembuatan Fetal Doppler Simulator
Denyut jantung janin (DJJ) adalah indikasi sensitif status janin, terutama karena berhubungan dengan kontraksi uterus. Pemantauan detak jantung janin tidak bisa dilakukan secara ka...
Simulator Fetal Doppler
Simulator Fetal Doppler
Fetal Doppler adalah alat diagnostik yang digunakan untuk mendeteksi denyut jantung bayi yang berada dalam kandungan. Denyut jantung janin (DJJ) adalah sebuah indikator dalam sebua...
Determination of fetal weight by ultrasonographic evaluation of fetal mid-thigh soft-tissue thickness in late third trimester
Determination of fetal weight by ultrasonographic evaluation of fetal mid-thigh soft-tissue thickness in late third trimester
Background: Estimation of fetal weight is of utmost importance in the planning and management of uneventful labor. This study was done to compare the estimated fetal weight determi...
<b>Umbilical Artery Doppler Indices In Hypertensive Disorders Of Pregnancy And Its Impact On Fetal Outcomes</b>
<b>Umbilical Artery Doppler Indices In Hypertensive Disorders Of Pregnancy And Its Impact On Fetal Outcomes</b>
Background: Hypertensive disorders of pregnancy are major contributors to placental insufficiency and adverse perinatal outcomes. Umbilical artery Doppler can be used to assess fet...
To Doppler or Not to Doppler: From Doppler Ultrasound to Color Doppler to Doppler in 3D and Beyond
To Doppler or Not to Doppler: From Doppler Ultrasound to Color Doppler to Doppler in 3D and Beyond
ABSTRACT
This review aims to provide the reader with an update on the present and potential clinical applications in Doppler ultrasound in perinatal medicine. Umbilical artery Dopp...