Fetal Doppler Simulator Based on Arduino

View through CrossRef
Heart rate of the fetal is the main indicator of the fetal life in the womb. Monitoring fetal heart rate can’t be done, so a tool is needed to monitoring fetal heart rate. Fetal heart rate can be monitored with fetal doppler. To test the accuracy of Fetal Doppler, a calibration is needed with the Fetal Doppler Simulator. This tool will simulate the fetal heart rate with a BPM value that can be adjusted according to the settings on the device. This module using Arduino as the brain system. On the module there is a selection of BPM  from 60 to 240 BPM with an increase of 30 BPM displayed on 2x16 character LCDs. Based on BPM measurement 6 times using Fetal Doppler, the measurement error in a BPM of 60 to BPM 210 is 0%, while at BPM 240 an error is 0.2%. This module has been compared with the standard devices (Fetal Simulator Brand Fluke Biomedical Ps320), the results of the comparison modules with the comparison tool  has the same error value in 240 BPM is 0.2% and in BPM 210 there is a difference in the result of module Fetal Doppler reading of 210 BPM while in the comparison tool is 209 BPM. Of the measurement data and analysis, it can be concluded that the tool can work and the tool has the same accuracy as the standard device.
Title: Fetal Doppler Simulator Based on Arduino
Description:
Heart rate of the fetal is the main indicator of the fetal life in the womb.
Monitoring fetal heart rate can’t be done, so a tool is needed to monitoring fetal heart rate.
Fetal heart rate can be monitored with fetal doppler.
To test the accuracy of Fetal Doppler, a calibration is needed with the Fetal Doppler Simulator.
This tool will simulate the fetal heart rate with a BPM value that can be adjusted according to the settings on the device.
This module using Arduino as the brain system.
On the module there is a selection of BPM  from 60 to 240 BPM with an increase of 30 BPM displayed on 2x16 character LCDs.
Based on BPM measurement 6 times using Fetal Doppler, the measurement error in a BPM of 60 to BPM 210 is 0%, while at BPM 240 an error is 0.
2%.
This module has been compared with the standard devices (Fetal Simulator Brand Fluke Biomedical Ps320), the results of the comparison modules with the comparison tool  has the same error value in 240 BPM is 0.
2% and in BPM 210 there is a difference in the result of module Fetal Doppler reading of 210 BPM while in the comparison tool is 209 BPM.
Of the measurement data and analysis, it can be concluded that the tool can work and the tool has the same accuracy as the standard device.

Related Results

Rancang Bangun Fetal Doppler Simulator untuk Kalibrasi Fetal Doppler
Rancang Bangun Fetal Doppler Simulator untuk Kalibrasi Fetal Doppler
Fetal Doppler Simulator untuk kalibrasi merupakan alat yang dirancang guna memastikan akurasi serta keandalan perangkat Fetal Doppler dalam memantau detak jantung janin. Selama ini...
Simulator approaches in otorhinolaryngology ‐ Looking beyond the ophthalmological horizon
Simulator approaches in otorhinolaryngology ‐ Looking beyond the ophthalmological horizon
Purpose: To improve medical students' learning of handheld otoscopy technique and findings based on a standardized simulator‐based procedure.Methods: A group of 120 medical student...
Application of Arduino Devices in various IOT Application
Application of Arduino Devices in various IOT Application
In this paper, v segribe the wireless sensor network system is the next open source hardware we've graded or raspberry arduino refers to an open source electronic operating system ...
Etiology and Outcome of Isolated Fetal Ascites
Etiology and Outcome of Isolated Fetal Ascites
OBJECTIVE: To describe the etiology of isolated fetal ascites and associated perinatal outcomes, and to assess the progression of isolated fetal ascites to fetal hydrop...
ANALISIS EFEK KECELAKAAN WATER INGRESS TERHADAP REAKTIVITAS DOPPLER TERAS RGTT200K
ANALISIS EFEK KECELAKAAN WATER INGRESS TERHADAP REAKTIVITAS DOPPLER TERAS RGTT200K
Dalam high temperature reactor, koefisien reaktivitas temperatur yang didesain negatif menjamin reaksi fisi dalam teras tetap berada di bawah kendali dan panas peluruhan tidak akan...
Platonic Simulation Theodicies
Platonic Simulation Theodicies
Abstract Using Platonic metaphysics, the paper offers eight arguments for the benevolence of the simulator of our world, assuming that it is a simulation. In part, the pa...
Application of Virtual Reality Technology in Nuclear Power Plant Control Room Simulator
Application of Virtual Reality Technology in Nuclear Power Plant Control Room Simulator
Main control room simulator is widely used in design verification and operator training for nuclear power plant. The simulator needs to implement the arrangement, environment, huma...
Older Drivers’ Motion and Simulator Sickness before and after Automated Vehicle Exposure
Older Drivers’ Motion and Simulator Sickness before and after Automated Vehicle Exposure
Older drivers desire independence in mobility, and automated vehicles hold plausible opportunities to realize this goal. Motion sickness (automated shuttle exposure) or simulator s...

Back to Top