Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Estimating installed cooling capacities on city scale

View through CrossRef
Heating and cooling of buildings is one of the largest final energy uses and largest sources of greenhouse gas emissions. To reduce the impact of heating and cooling on our climate, more efficient strategies are needed. Coupling and centralizing the production of heat and cold in combination with underground seasonal thermal storage (UTES) can significantly reduce CO2 emissions and costs. To plan and implement such strategies for heating and cooling, information on sources and sinks of heat and cold is essential for local authorities. However, spatial information on the cooling sector is rare and difficult to obtain. Often, the theoretical cooling demand of specific buildings and building types is modeled, but not met by air-conditioning equipment in reality. On the other hand, large-scale cooling demand models, which focus on entire countries, may use data from different countries as proxy or are not applicable below kilometer-scale.In this study, we present a method to identify air-conditioning equipment on the rooftops of buildings and quantify their cooling capacity. Thus, air-cooled and hybrid evaporative condensers, cooling towers and packaged rooftop units are detected on aerial images. Using manufacturer data, regression analyses are created to estimate the cooling capacity based on the size of the units and the number of condenser fans. The unit locations and all required parameters are obtained by convolutional neural network-based pixel classification models, which are easily executable within a geographical information system (GIS) framework. The approach is successfully evaluated by testing the capability of the detection models and comparing our estimated cooling capacities to the actual installed cooling capacities of air-conditioners for different locations. The detection performance strongly depends on the resolution of the used aerial images. At a resolution of 8 cm/pixel, the model detects 93% of the units and the pixel classification overestimates the relevant parameters for the regression by 0.7%. Using the regression analyses, the overall capacity in the evaluated areas is overestimated by 7-21%. To demonstrate the capability of our approach, we map the cooling capacity of air-conditioners in parts of Manhattan. In the Manhattan financial district alone, a cooling capacity of over 2 GW is estimated, which is equivalent to 1.3% of the summer peak load demand of the energy grid of the entire state of New York.The presented approach is a fast and easy to conduct method that requires little input data. It can detect individual air conditioners over large areas. The obtained information can support the creation of cooling cadastres and can serve as supplement or validation for other cooling demand models, such as building stock models, or example to include additional building types, such as industrial buildings.
Title: Estimating installed cooling capacities on city scale
Description:
Heating and cooling of buildings is one of the largest final energy uses and largest sources of greenhouse gas emissions.
To reduce the impact of heating and cooling on our climate, more efficient strategies are needed.
Coupling and centralizing the production of heat and cold in combination with underground seasonal thermal storage (UTES) can significantly reduce CO2 emissions and costs.
To plan and implement such strategies for heating and cooling, information on sources and sinks of heat and cold is essential for local authorities.
However, spatial information on the cooling sector is rare and difficult to obtain.
Often, the theoretical cooling demand of specific buildings and building types is modeled, but not met by air-conditioning equipment in reality.
On the other hand, large-scale cooling demand models, which focus on entire countries, may use data from different countries as proxy or are not applicable below kilometer-scale.
In this study, we present a method to identify air-conditioning equipment on the rooftops of buildings and quantify their cooling capacity.
Thus, air-cooled and hybrid evaporative condensers, cooling towers and packaged rooftop units are detected on aerial images.
Using manufacturer data, regression analyses are created to estimate the cooling capacity based on the size of the units and the number of condenser fans.
The unit locations and all required parameters are obtained by convolutional neural network-based pixel classification models, which are easily executable within a geographical information system (GIS) framework.
The approach is successfully evaluated by testing the capability of the detection models and comparing our estimated cooling capacities to the actual installed cooling capacities of air-conditioners for different locations.
The detection performance strongly depends on the resolution of the used aerial images.
At a resolution of 8 cm/pixel, the model detects 93% of the units and the pixel classification overestimates the relevant parameters for the regression by 0.
7%.
Using the regression analyses, the overall capacity in the evaluated areas is overestimated by 7-21%.
To demonstrate the capability of our approach, we map the cooling capacity of air-conditioners in parts of Manhattan.
In the Manhattan financial district alone, a cooling capacity of over 2 GW is estimated, which is equivalent to 1.
3% of the summer peak load demand of the energy grid of the entire state of New York.
The presented approach is a fast and easy to conduct method that requires little input data.
It can detect individual air conditioners over large areas.
The obtained information can support the creation of cooling cadastres and can serve as supplement or validation for other cooling demand models, such as building stock models, or example to include additional building types, such as industrial buildings.

Related Results

ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
<p><em><span class="markedContent"><span style="left: calc(var(--scale-factor)*195.53px); top: calc(var(--scale-factor)*496.87px); font-size: calc(var(--scale-...
KEDUDUKAN AHLI BAHASA DALAM PEMBUKTIAN PERKARA PENCEMARAN NAMA BAIK (STUDI PUTUSAN NOMOR: 47/PID.SUS/2019/PN. MGT)
KEDUDUKAN AHLI BAHASA DALAM PEMBUKTIAN PERKARA PENCEMARAN NAMA BAIK (STUDI PUTUSAN NOMOR: 47/PID.SUS/2019/PN. MGT)
<em><span id="page3R_mcid52" class="markedContent"><span style="left: calc(var(--scale-factor)*125.30px); top: calc(var(--scale-factor)*539.11px); font-size: calc(va...
Selective Head Cooling in Newborn Infants After Perinatal Asphyxia: A Safety Study
Selective Head Cooling in Newborn Infants After Perinatal Asphyxia: A Safety Study
Aims.To determine the practicality and safety of head cooling with mild or minimal systemic hypothermia in term neonates with moderate to severe hypoxic-ischemic encephalopathy.Met...
Application of Machine Learning Based Meta Models for Predicting Film Cooling Effectiveness in Gas Turbine Blades
Application of Machine Learning Based Meta Models for Predicting Film Cooling Effectiveness in Gas Turbine Blades
Abstract In Large Gas Turbines, turbine components in particular blades and vanes operate at significantly high temperatures. As a result, cooling of these component...
Study on Flow Coefficient of Film Cooling Hole in Combustor
Study on Flow Coefficient of Film Cooling Hole in Combustor
The cooling hole is an important structural component of gas turbine combustion chamber. A part of air enters the combustion chamber through the cooling hole through the external p...
Estimating cooling capacities from aerial images using convolutional neural networks
Estimating cooling capacities from aerial images using convolutional neural networks
In recent decades, the global cooling demand has significantly increased and is expected to grow even further in the future. However, knowledge regarding the spatial distribution o...
Innovative Turbine Intake Air Cooling Systems and Their Rational Designing
Innovative Turbine Intake Air Cooling Systems and Their Rational Designing
The efficiency of cooling ambient air at the inlet of gas turbines in temperate climatic conditions was analyzed and reserves for its enhancing through deep cooling were revealed. ...
Experimental Feasibility Study of Radial Injection Cooling of Three-Pad Air Foil Bearings
Experimental Feasibility Study of Radial Injection Cooling of Three-Pad Air Foil Bearings
The foil bearing (FB) is one type of hydrodynamic bearing using air or another gas as a lubricant. When FBs are designed, installed, and operated properly, they are a very cost-eff...

Back to Top