Techniques of Aortic Valve Repair
View through CrossRef
Similar to mitral repair, newer methods of aortic valve reconstruction are achieving excellent outcomes with an 85% to 90% freedom from valve-related complications at 10 years. The goal of this review is to illustrate these newer and more stable techniques of aortic valve repair. Most patients with aortic insufficiency from either trileaflet or bicuspid aortic valves are candidates for repair, in addition to selected patients with mixed aortic stenosis/insufficiency and aortic root aneurysms. Initially, aggressive commissural annuloplasty is performed to reduce measured valve diameter to 19 to 21 mm. Leaflet prolapse is corrected with plication stitches placed in the free edge of each leaflet adjacent to the Nodulus Arantius. In this regard, the leaflet free edge functions as the chorda tendinea of the aortic valve, and shortening with plication stitches raises the leaflet to a proper “effective height.” Leaflet defects are augmented with gluteraldehyde-fixed autologous pericardium, and mild-to-moderate strategically placed spicules of calcium are removed with the cavitron ultrasonic surgical aspirator. Using these methods, most insufficient aortic valves, and many with mixed lesions, can be satisfactorily repaired. Six cases are illustrated in this review, spanning the spectrum of pathologies from annular dilatation without leaflet defects, to standard congenital bicuspid valve with prolapse, to trileaflet prolapse, to unusual bicuspid pathology with calcification, to a moderately calcified trileaflet valve with mixed lesions, and to aortic root aneurysms with severe aortic insufficiency. All valves were repaired using the techniques described above with trivial residual leak and minimal gradients. All repairs have been followed with yearly echocardiography, and valve reconstruction with these methods is now quite stable with excellent late outcomes. Most insufficient aortic valves now can undergo stable repair with minimal late valve-related complications. Greater application of aortic valve repair seems indicated.
Title: Techniques of Aortic Valve Repair
Description:
Similar to mitral repair, newer methods of aortic valve reconstruction are achieving excellent outcomes with an 85% to 90% freedom from valve-related complications at 10 years.
The goal of this review is to illustrate these newer and more stable techniques of aortic valve repair.
Most patients with aortic insufficiency from either trileaflet or bicuspid aortic valves are candidates for repair, in addition to selected patients with mixed aortic stenosis/insufficiency and aortic root aneurysms.
Initially, aggressive commissural annuloplasty is performed to reduce measured valve diameter to 19 to 21 mm.
Leaflet prolapse is corrected with plication stitches placed in the free edge of each leaflet adjacent to the Nodulus Arantius.
In this regard, the leaflet free edge functions as the chorda tendinea of the aortic valve, and shortening with plication stitches raises the leaflet to a proper “effective height.
” Leaflet defects are augmented with gluteraldehyde-fixed autologous pericardium, and mild-to-moderate strategically placed spicules of calcium are removed with the cavitron ultrasonic surgical aspirator.
Using these methods, most insufficient aortic valves, and many with mixed lesions, can be satisfactorily repaired.
Six cases are illustrated in this review, spanning the spectrum of pathologies from annular dilatation without leaflet defects, to standard congenital bicuspid valve with prolapse, to trileaflet prolapse, to unusual bicuspid pathology with calcification, to a moderately calcified trileaflet valve with mixed lesions, and to aortic root aneurysms with severe aortic insufficiency.
All valves were repaired using the techniques described above with trivial residual leak and minimal gradients.
All repairs have been followed with yearly echocardiography, and valve reconstruction with these methods is now quite stable with excellent late outcomes.
Most insufficient aortic valves now can undergo stable repair with minimal late valve-related complications.
Greater application of aortic valve repair seems indicated.
Related Results
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
Objectives
To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia.
...
Valve-Sparing Aortic Root Replacement by Congenital Heart Surgeons: A Single Center Experience.
Valve-Sparing Aortic Root Replacement by Congenital Heart Surgeons: A Single Center Experience.
Background Aortic root dilatation and aortic insufficiency can
occur in patients with prior conotruncal defect surgery, the Ross
procedure, and connective tissue disease (CTD). Val...
An Acoustically Controlled Down-Hole Safety Valve (SCSSSV)
An Acoustically Controlled Down-Hole Safety Valve (SCSSSV)
American Institute of Mining, Metallurgical, and Petroleum Engineers, Inc.
Abstract
A surface-controlled subsurface safety valve...
Small Aortic Annulus: Aortic Allografts vs Perceval S
Small Aortic Annulus: Aortic Allografts vs Perceval S
Цель. Оценить и сравнить гемодинамические показатели и изменение качества жизни после имплантации протезов Perceval S и аортальных аллографтов, а также частоту и спектр осложнений ...
Incidence, predictors and outcomes of Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR): a systematic review and meta-analysis
Incidence, predictors and outcomes of Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR): a systematic review and meta-analysis
Abstract
Background
Surgical aortic valve replacement has been the treatment of choice for patients with aortic valve disease be...
Prevalence of Patients With Severe Aortic Stenosis, Low Flow And Preserved Ejection Fraction: Results From a Cath-Lab Data Base.
Prevalence of Patients With Severe Aortic Stenosis, Low Flow And Preserved Ejection Fraction: Results From a Cath-Lab Data Base.
AbstractRecent echocardiographic studies described that almost 30% of patients with severe aortic valve stenosis on the basis of aortic valve area may paradoxically have a relative...
Fluid–Structure Interaction Aortic Valve Surgery Simulation: A Review
Fluid–Structure Interaction Aortic Valve Surgery Simulation: A Review
The complicated interaction between a fluid flow and a deformable structure is referred to as fluid–structure interaction (FSI). FSI plays a crucial role in the functioning of the ...
Early results of mitral vavle repair of degenerative mitral valve regurgitation
Early results of mitral vavle repair of degenerative mitral valve regurgitation
Background: Mitral valve regurgitation due to degenerative valve disease is a common disease affecting about 2% of the population, mainly in developed countries [2],[6]. Medical t...