Profil Dosis Sekunder Ct Scan Sinus Paranasal Dengan Aplikasi Software Organ Dose Modulation (ODM)

View through CrossRef
Background: A radiological examination that can be used to evaluate SPN and facial bones is CT SPN. CT SPN increases the potential risk of radiation effects, especially on sensitive organs (thyroid and mammae). CT SPN exposure does not only affect the main organs but also the surrounding organs (secondary doses). The secondary dose also increases the risk of stochastic effects. Unfortunately, secondary doses are rarely measured. So, there is a need for safety and radiation protection like using Organ Dose Modulation (ODM) software. The purpose of this study was To determine the secondary dose in CT SPN using ODM software. Methods: This research is quantitative research with an experimental study approach carried out in March–May 2023 at the Radiology Installation of Indriati Solo Baru Hospital. This research was carried out by scanning the phantom with standard CT SPN protocol and adding ODM software, then measuring the dose using TLD BARC which was placed on the thyroid and mammae area. The results of the absorbed dose in thyroid and mammae were analyzed descriptively and analytically. Result: The mean absorbed dose value in the thyroid gland area without ODM software was 9.44 mSv and with ODM software was 5.12 mSv. In the breast area without ODM software, the mean absorbed dose value was 0.85 mSv, while using ODM software was 0.59 mSv. The decreased absorbed dose using ODM software in the thyroid is 44,57% and in the breast is 29,85%. Conclusion: Using ODM software in CT SPN can reduce the secondary dose (thyroid and breast areas)
Title: Profil Dosis Sekunder Ct Scan Sinus Paranasal Dengan Aplikasi Software Organ Dose Modulation (ODM)
Description:
Background: A radiological examination that can be used to evaluate SPN and facial bones is CT SPN.
CT SPN increases the potential risk of radiation effects, especially on sensitive organs (thyroid and mammae).
CT SPN exposure does not only affect the main organs but also the surrounding organs (secondary doses).
The secondary dose also increases the risk of stochastic effects.
Unfortunately, secondary doses are rarely measured.
So, there is a need for safety and radiation protection like using Organ Dose Modulation (ODM) software.
The purpose of this study was To determine the secondary dose in CT SPN using ODM software.
Methods: This research is quantitative research with an experimental study approach carried out in March–May 2023 at the Radiology Installation of Indriati Solo Baru Hospital.
This research was carried out by scanning the phantom with standard CT SPN protocol and adding ODM software, then measuring the dose using TLD BARC which was placed on the thyroid and mammae area.
The results of the absorbed dose in thyroid and mammae were analyzed descriptively and analytically.
Result: The mean absorbed dose value in the thyroid gland area without ODM software was 9.
44 mSv and with ODM software was 5.
12 mSv.
In the breast area without ODM software, the mean absorbed dose value was 0.
85 mSv, while using ODM software was 0.
59 mSv.
The decreased absorbed dose using ODM software in the thyroid is 44,57% and in the breast is 29,85%.
Conclusion: Using ODM software in CT SPN can reduce the secondary dose (thyroid and breast areas).

Related Results

Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND
Verifikasi Dosis Radiasi Teknik Penyinaran 3D-CRT pada Pasien Kanker Payudara Menggunakan Film EBT3 di Rumah Sakit UNAND
Verifikasi dosis radiasi teknik penyinaran Three-Dimensional Conformal Radiation Therapy  (3D-CRT) pada pasien kanker payudara telah dilakukan menggunakan film EBT3. Verifikasi do...
Multiple Concurrent Pilonidal Sinuses: Case report and Literature review
Multiple Concurrent Pilonidal Sinuses: Case report and Literature review
Abstract Introduction: Concurrent pilonidal sinuses (PNSs) at distinct locations are extremely rare. This report highlights an exceptional case of a young female presenting with th...
Maxillary Antrum Carcinoma - A Wolf in Sheep’s Clothing
Maxillary Antrum Carcinoma - A Wolf in Sheep’s Clothing
Maxillary sinus squamous cell carcinoma is an invasive tumour that is usually diagnosed at an advanced stage, where the majority of patients have a very low prognosis and survival ...
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature  Review Anna Tri Wahyuni1), Masfuri2),  Liya Arista3)1,2,3 Fakultas Ilmu Keperawatan Univers...
PENGARUH PUPUK Si DAN N, P, K TERHADAP KANDUNGAN Si DAN HASIL TANAMAN JAGUNG MANIS (Zea mays L. Saccaharata)
PENGARUH PUPUK Si DAN N, P, K TERHADAP KANDUNGAN Si DAN HASIL TANAMAN JAGUNG MANIS (Zea mays L. Saccaharata)
Pertumbuhan dan produksi tanaman dipengaruhi oleh berbagai karakteristik tanah terutama kesuburan tanah yang berkaitan dengan ketersediaan unsur hara. Pengelolaan kesuburan  tanah ...
Total Aplasia of the Paranasal Sinuses
Total Aplasia of the Paranasal Sinuses
Although a variety of theories have been proposed about functions of the paranasal sinuses, not one is clear today. Nonetheless, paranasal sinus–related diseases are associated wit...
COMPARISON BETWEEN IMAGING TECHNOLOGIES (X-RAY WITH COMPUTE TOMOGRAPHY SCAN) OF PARANASAL SINUSES (PNS) IN SINUSITIS PATIENTS
COMPARISON BETWEEN IMAGING TECHNOLOGIES (X-RAY WITH COMPUTE TOMOGRAPHY SCAN) OF PARANASAL SINUSES (PNS) IN SINUSITIS PATIENTS
Background: Imaging technologies like x-ray and computed tomography used in study of paranasal sinuses plays an important role in managing multiple pathologies. Modern imaging tech...