Javascript must be enabled to continue!
Surveillance Neutron Dosimetry at the Hungarian Nuclear Power Plant
View through CrossRef
Three reactor blocks of WWER-440 type have been put into operation at the Paks Hungary, nuclear power plant (NPP) from 1983. In the frame of the reactor vessel surveillance program accelerated capsules (LF > 10) have been used. Three surveillance sequences with the first reactor block and two sequences with the second have been evaluated to date.
Surveillance neutron dosimetry analysis and the results of related investigations (ex-vessel dosimetry, additional capsule irradiation) performed in order to improve the life-time assessment of the reactor pressure vessel are presented. Very good agreement between the dpa and fast neutron flux (E > 0.5 MeV) lead factors (LF) was found for the spectrum of interest. The results obtained to date show that the reactor can be safely operated until the end of its designed service life (40 years).
ASTM International100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959
Title: Surveillance Neutron Dosimetry at the Hungarian Nuclear Power Plant
Description:
Three reactor blocks of WWER-440 type have been put into operation at the Paks Hungary, nuclear power plant (NPP) from 1983.
In the frame of the reactor vessel surveillance program accelerated capsules (LF > 10) have been used.
Three surveillance sequences with the first reactor block and two sequences with the second have been evaluated to date.
Surveillance neutron dosimetry analysis and the results of related investigations (ex-vessel dosimetry, additional capsule irradiation) performed in order to improve the life-time assessment of the reactor pressure vessel are presented.
Very good agreement between the dpa and fast neutron flux (E > 0.
5 MeV) lead factors (LF) was found for the spectrum of interest.
The results obtained to date show that the reactor can be safely operated until the end of its designed service life (40 years).
Related Results
Comparative study of the effect of neutrons emitted from neutron source 241Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Comparative study of the effect of neutrons emitted from neutron source 241Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
AbstractIntroductionCancer is one of the major medical problems threatening human health. Breast cancer is the most prevalent type of cancer in women. Reports indicate that treatme...
Study of coded source neutron imaging based on a compact accelerator
Study of coded source neutron imaging based on a compact accelerator
Compact accelerator based neutron source has lower cost and better flexibility than nuclear reactor. Neutron imaging using such a neutron source has attracted more and more attenti...
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
Porosity is one of the essential parameters in conventional oil and gas reservoir evaluation, as well as plays an important role in the calculation of formation saturation and rese...
Public Perception of Nuclear Power Risk in China and Methods to Improve Public Acceptance
Public Perception of Nuclear Power Risk in China and Methods to Improve Public Acceptance
At present, the most influencing factor on nuclear power’s development in China the public’s attitude and acceptance. This paper studies the public perception of nuclear power risk...
Public Acceptance of Spent Fuel Reprocessing Project
Public Acceptance of Spent Fuel Reprocessing Project
At present, there are hundreds of nuclear power plants in operation around the world. Anti-nuclear movements continue in many places, although the nuclear power plants have good op...
CAN A NEW DOUBLE PARTICLE DETECTOR-CLYC (CS2LIYCL6:CE) BE USED IN PN LOGGING FOR TIGHT GAS EVALUATION?
CAN A NEW DOUBLE PARTICLE DETECTOR-CLYC (CS2LIYCL6:CE) BE USED IN PN LOGGING FOR TIGHT GAS EVALUATION?
Unconventional oil and gas resources, such as tight oil and gas, have become indispensably succeeding energy sources in nowadays. At the stage of exploration, gas saturation is ess...
AN ACCURATELY DETERMINING POROSITY METHOD FROM PULSED-NEUTRON ELEMENT LOGGING IN UNCONVENTIONAL RESERVOIRS
AN ACCURATELY DETERMINING POROSITY METHOD FROM PULSED-NEUTRON ELEMENT LOGGING IN UNCONVENTIONAL RESERVOIRS
Unconventional reservoirs have low porosity and complex mineral composition containing quartz, feldspar, calcite, dolomite, pyrite and kerogen, which may seriously reduce the accur...
Reactor Dosimetry and Nuclear Reactor Regulation
Reactor Dosimetry and Nuclear Reactor Regulation
An important function of reactor dosimetry is the verification of fluence values used in the calculation of pressure vessel embrittlement and its impact on (a) the fracture toughne...