Performance Assessment of First-Generation Anti-SARS-CoV-2 Serological Assays

View through CrossRef
ABSTRACT The clinical and epidemiological use of SARS-CoV-2 antibody assays is under debate with urgent need to validate and verify the performance of SARS-CoV-2 serologic assays. We aim to assess the clinical and analytical performance of three commercial serological assays of SARS-CoV-2, comparing three anti-SARS-CoV-2-IgG ELISA and identifying the seroconversion and seroprevalence in our population. A cross sectional study conducted from April 2020 to July 2020 at National Institute of Blood disease and Bone Marrow Transplantation Karachi, Pakistan with sample size of 404, enrolled consecutively. Participants were categorized into four groups’ namely convalescent plasmadonors (CPDs n=239), health care professionals (HCPs n=44), healthy blood donors (HBDs n=70) and from community (n=51). We evaluated the performance of Elecsys anti-SARS-CoV-2 electrochemiluminescence (ECLIA) assay on Cobas-e411 by Roche, three qualitative anti-SARS-CoV-2-IgG enzyme linked imunosorbant assay (ELISA) by (Generic assays, Euroimmun & Omega diagnostics), one quantitative ELISA assay by AESKU Diagnostics and two immune chromatography(ICT) kits namely InstaTest™ by CORTEZ and TEST IT by TURKLAB. From total 404 subjects, 322 (83.5%) were males. Mean age was 36.79±11.95 years. Among 239 in CPDs group, 202(84.5%) showed positive antibodies by ECLIA. The qualitative anti-SARS-CoV-2 IgG ELISA was positive in 174 (72.8%) and quantitative IgG in 180(75.3%) with mean titer of 56.7 ±39.7 U/ml. Sensitivity and specificity of ECLIA were 97.44& 99%, ELISA by Generic assays were 67.85% and 89.9%; Euroimmun had 90.38% and 94.9%; Omega Diagnostics 96.4% and 95% and the AESKULISA 93.75% and 100% respectively. Seroconversion was found to be 53.8% and 77.77% within 7 -8 days and 12 to 14 days post onset of symptoms respectively. ICT had more specificity but less sensitivity. Seroprevalence was found to be 84.5%, 40.9% and 21.4% in CPDs, HCPs and HBDs respectively. The Roche ECLIA, qualitative ELISA by Omega Diagnostics & Euroimmun showed higher sensitivity as well as higher specificity. Quantitative ELISA has higher specificity and relatively high sensitivity. Significant numbers of COVID patients do not have detectable antibodies by all assays.
Title: Performance Assessment of First-Generation Anti-SARS-CoV-2 Serological Assays
Description:
ABSTRACT The clinical and epidemiological use of SARS-CoV-2 antibody assays is under debate with urgent need to validate and verify the performance of SARS-CoV-2 serologic assays.
We aim to assess the clinical and analytical performance of three commercial serological assays of SARS-CoV-2, comparing three anti-SARS-CoV-2-IgG ELISA and identifying the seroconversion and seroprevalence in our population.
A cross sectional study conducted from April 2020 to July 2020 at National Institute of Blood disease and Bone Marrow Transplantation Karachi, Pakistan with sample size of 404, enrolled consecutively.
Participants were categorized into four groups’ namely convalescent plasmadonors (CPDs n=239), health care professionals (HCPs n=44), healthy blood donors (HBDs n=70) and from community (n=51).
We evaluated the performance of Elecsys anti-SARS-CoV-2 electrochemiluminescence (ECLIA) assay on Cobas-e411 by Roche, three qualitative anti-SARS-CoV-2-IgG enzyme linked imunosorbant assay (ELISA) by (Generic assays, Euroimmun & Omega diagnostics), one quantitative ELISA assay by AESKU Diagnostics and two immune chromatography(ICT) kits namely InstaTest™ by CORTEZ and TEST IT by TURKLAB.
From total 404 subjects, 322 (83.
5%) were males.
Mean age was 36.
79±11.
95 years.
Among 239 in CPDs group, 202(84.
5%) showed positive antibodies by ECLIA.
The qualitative anti-SARS-CoV-2 IgG ELISA was positive in 174 (72.
8%) and quantitative IgG in 180(75.
3%) with mean titer of 56.
7 ±39.
7 U/ml.
Sensitivity and specificity of ECLIA were 97.
44& 99%, ELISA by Generic assays were 67.
85% and 89.
9%; Euroimmun had 90.
38% and 94.
9%; Omega Diagnostics 96.
4% and 95% and the AESKULISA 93.
75% and 100% respectively.
Seroconversion was found to be 53.
8% and 77.
77% within 7 -8 days and 12 to 14 days post onset of symptoms respectively.
ICT had more specificity but less sensitivity.
Seroprevalence was found to be 84.
5%, 40.
9% and 21.
4% in CPDs, HCPs and HBDs respectively.
The Roche ECLIA, qualitative ELISA by Omega Diagnostics & Euroimmun showed higher sensitivity as well as higher specificity.
Quantitative ELISA has higher specificity and relatively high sensitivity.
Significant numbers of COVID patients do not have detectable antibodies by all assays.

Related Results

Performance characteristics of the VIDAS® SARS-COV-2 IgM and IgG serological assays
Performance characteristics of the VIDAS® SARS-COV-2 IgM and IgG serological assays
ABSTRACTThe COVID-19 pandemic, caused by the new severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), continues to spread worldwide. Serological testing for SARS-CoV-2-spe...
From SARS and MERS CoVs to SARS‐CoV‐2: Moving toward more biased codon usage in viral structural and nonstructural genes
From SARS and MERS CoVs to SARS‐CoV‐2: Moving toward more biased codon usage in viral structural and nonstructural genes
AbstractBackgroundSevere acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) is an emerging disease with fatal outcomes. In this study, a fundamental knowledge gap question is to...
SARS-CoV-2 within-host diversity of human hosts and its implications for viral immune evasion
SARS-CoV-2 within-host diversity of human hosts and its implications for viral immune evasion
ABSTRACT Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is continuously evolving, bringing great challenges to the control of the virus. In the...
The emerging SARS‐CoV‐2 papain‐like protease: Its relationship with recent coronavirus epidemics
The emerging SARS‐CoV‐2 papain‐like protease: Its relationship with recent coronavirus epidemics
AbstractThe papain‐like protease (PLpro) is an important enzyme for coronavirus polyprotein processing, as well as for virus‐host immune suppression. Previous studies reveal that a...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Expanding access to SARS-CoV-2 IgG and IgM serologic testing using fingerstick whole blood, plasma, and rapid lateral flow assays
Expanding access to SARS-CoV-2 IgG and IgM serologic testing using fingerstick whole blood, plasma, and rapid lateral flow assays
AbstractSerologic testing for SARS-CoV-2 antibodies can be used to confirm diagnosis, estimate seroprevalence, screen convalescent plasma donors, and assess vaccine efficacy. Sever...
SARS-CoV-2 cell-to-cell infection is resistant to neutralizing antibodies
SARS-CoV-2 cell-to-cell infection is resistant to neutralizing antibodies
AbstractThe COVID-19 pandemic caused by SARS-CoV-2 has posed a global threat to human lives and economics. One of the best ways to determine protection against the infection is to ...
Resistance of endothelial cells to SARS-CoV-2 infectionin vitro
Resistance of endothelial cells to SARS-CoV-2 infectionin vitro
AbstractRationaleThe secondary thrombotic/vascular clinical syndrome of COVID-19 suggests that SARS-CoV-2 infects not only respiratory epithelium but also the endothelium activatin...

Back to Top