Expanding access to SARS-CoV-2 IgG and IgM serologic testing using fingerstick whole blood, plasma, and rapid lateral flow assays
View through CrossRef
AbstractSerologic testing for SARS-CoV-2 antibodies can be used to confirm diagnosis, estimate seroprevalence, screen convalescent plasma donors, and assess vaccine efficacy. Several logistical and infrastructure challenges limit access to SARS-CoV-2 serologic testing. Dried blood spot (DBS) samples have been used for serology testing of various diseases in resource-limited settings. We examined the use of DBS samples and capillary blood (fingerstick) plasma collected in Microtainer tubes for SARS-CoV-2 testing with the automated Abbott ARCHITECT™ SARS-CoV-2 IgG (List 6R86) and IgM assays and use of venous whole blood with a prototype PANBIO™ rapid point-of-care lateral flow SARS-CoV-2 IgG assay. The ARCHITECT™ SARS-CoV-2 IgG assay was initially optimized for use with DBS, venous and capillary plasma, and venous whole blood collected from patients with symptoms and PCR-confirmed COVID-19 and negative asymptomatic controls. Assay linearity and reproducibility was confirmed with 3 contrived DBS samples, with sample stability and signal recovery after 14 days at room temperature. ARCHITECT™ SARS-CoV-2 IgG and IgM assay results showed high concordance between fingerstick DBS and venous DBS samples, and between fingerstick DBS and venous whole blood samples (n=61). Discordant results were seen in 3 participants (2 IgG, 1 IgM) who were in the process of seroreversion at the time of sample collection and had results near the assay cutoff. Use of fingerstick plasma collected in Microtainer tubes (n=109) showed 100% concordant results (R2=0.997) with matched patient venous plasma on the ARCHITECT™ SARS-CoV-2 IgG assay. High concordance of assay results (92.9% positive, 100% negative) was also observed for the PANBIO™ SARS-CoV-2 IgG assay compared to the ARCHITECT™ SARS-CoV-2 IgG assay run with matched venous plasma (n=61). Fingerstick DBS and plasma samples are easy and inexpensive to collect and, along with the use of rapid point-of-care testing platforms, will expand access to SARS-CoV-2 serology testing, particularly in resource-limited areas.
Cold Spring Harbor Laboratory
Title: Expanding access to SARS-CoV-2 IgG and IgM serologic testing using fingerstick whole blood, plasma, and rapid lateral flow assays
Description:
AbstractSerologic testing for SARS-CoV-2 antibodies can be used to confirm diagnosis, estimate seroprevalence, screen convalescent plasma donors, and assess vaccine efficacy.
Several logistical and infrastructure challenges limit access to SARS-CoV-2 serologic testing.
Dried blood spot (DBS) samples have been used for serology testing of various diseases in resource-limited settings.
We examined the use of DBS samples and capillary blood (fingerstick) plasma collected in Microtainer tubes for SARS-CoV-2 testing with the automated Abbott ARCHITECT™ SARS-CoV-2 IgG (List 6R86) and IgM assays and use of venous whole blood with a prototype PANBIO™ rapid point-of-care lateral flow SARS-CoV-2 IgG assay.
The ARCHITECT™ SARS-CoV-2 IgG assay was initially optimized for use with DBS, venous and capillary plasma, and venous whole blood collected from patients with symptoms and PCR-confirmed COVID-19 and negative asymptomatic controls.
Assay linearity and reproducibility was confirmed with 3 contrived DBS samples, with sample stability and signal recovery after 14 days at room temperature.
ARCHITECT™ SARS-CoV-2 IgG and IgM assay results showed high concordance between fingerstick DBS and venous DBS samples, and between fingerstick DBS and venous whole blood samples (n=61).
Discordant results were seen in 3 participants (2 IgG, 1 IgM) who were in the process of seroreversion at the time of sample collection and had results near the assay cutoff.
Use of fingerstick plasma collected in Microtainer tubes (n=109) showed 100% concordant results (R2=0.
997) with matched patient venous plasma on the ARCHITECT™ SARS-CoV-2 IgG assay.
High concordance of assay results (92.
9% positive, 100% negative) was also observed for the PANBIO™ SARS-CoV-2 IgG assay compared to the ARCHITECT™ SARS-CoV-2 IgG assay run with matched venous plasma (n=61).
Fingerstick DBS and plasma samples are easy and inexpensive to collect and, along with the use of rapid point-of-care testing platforms, will expand access to SARS-CoV-2 serology testing, particularly in resource-limited areas.
Related Results
Performance characteristics of the VIDAS® SARS-COV-2 IgM and IgG serological assays
Performance characteristics of the VIDAS® SARS-COV-2 IgM and IgG serological assays
ABSTRACTThe COVID-19 pandemic, caused by the new severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), continues to spread worldwide. Serological testing for SARS-CoV-2-spe...
Evaluation of the Performance Characteristics for SARS-CoV-2 S-RBD IgG Antibody Rapid Test Cassette (Fingerstick Whole Blood) by Comparing CLIA Test
Evaluation of the Performance Characteristics for SARS-CoV-2 S-RBD IgG Antibody Rapid Test Cassette (Fingerstick Whole Blood) by Comparing CLIA Test
Background: SARS-CoV-2, a branch of coronavirus, is a positive-strand RNA virus with four major proteins and several auxiliary proteins wrapped with genetic material. It mediates t...
Kinetics of the humoral immune response to SARS-CoV-2: comparative analytical performance of seven commercial serology tests
Kinetics of the humoral immune response to SARS-CoV-2: comparative analytical performance of seven commercial serology tests
Abstract
Background
SARS-CoV-2 serology tests are clinically useful to document a prior SARS-CoV-2 infection in patients with n...
The Potential of Medicinal Plants and Bioactive Compounds in the Fight Against COVID-19
The Potential of Medicinal Plants and Bioactive Compounds in the Fight Against COVID-19
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), a novel coronavirus , is causing a serious worldwide COVID-19 pandemic. The emergence of strains with rapid spread and...
The Hidden Problem of Cross-Reactivity: Challenges in HIV Testing During the COVID-19 Era: A Systematic Review
The Hidden Problem of Cross-Reactivity: Challenges in HIV Testing During the COVID-19 Era: A Systematic Review
Abstract
Introduction
Human immunodeficiency virus (HIV) and Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV2) surface glycoproteins, including shared epitope motifs, sho...
Patterns of antiphospholipid antibody positivity in a real-world laboratory over two decades
Patterns of antiphospholipid antibody positivity in a real-world laboratory over two decades
Abstract
Background Antiphospholipid syndrome (APS) is diagnosed when vascular thrombosis or pregnancy morbidity occurs ...
Humoral Immune Response to SARS-CoV-2
Humoral Immune Response to SARS-CoV-2
Abstract
Objectives
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serology tests are clinically useful to ...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...