Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Evaluating ELISA, Immunofluorescence, and Lateral Flow Assay for SARS-CoV-2 Serologic Assays

View through CrossRef
BackgroundThe SARS-CoV-2 outbreak has emerged at the end of 2019. Aside from the detection of viral genome with specific RT-PCR, there is a growing need for reliable determination of the serological status. We aimed at evaluating five SARS-CoV-2 serology assays.MethodsAn in-house immunofluorescence assay (IFA), two ELISA kits (EUROIMMUN® ELISA SARS-CoV-2 IgG and NovaLisa® SARS-CoV-2 IgG and IgM) and two lateral flow assays (T-Tek® SARS-CoV-2 IgG/IgM Antibody Test Kit and Sure Bio-tech® SARS-CoV-2 IgM/IgG Antibody Rapid Test) were compared on 40 serums from RT-PCR-confirmed SARS-CoV-2 infected patients and 10 SARS-CoV-2 RT-PCR negative subjects as controls.ResultsControl subjects tested negative for SARS-CoV-2 antibodies with all five systems. Estimated sensitivities varied from 35.5 to 71.0% for IgG detection and from 19.4 to 64.5% for IgM detection. For IgG, in-house IFA, EuroImmun, T-Tek and NovaLisa displayed 50–72.5% agreement with other systems except IFA vs EuroImmun and T-Tek vs NovaLisa. Intermethod agreement for IgM determination was between 30 and 72.5%.DiscussionThe overall intermethod agreement was moderate. This inconsistency could be explained by the diversity of assay methods, antigens used and immunoglobulin isotype tested. Estimated sensitivities were low, highlighting the limited value of antibody detection in CoVID-19.ConclusionComparison of five systems for SARS-CoV-2 IgG and IgM antibodies showed limited sensitivity and overall concordance. The place and indications of serological status assessment with currently available tools in the CoVID-19 pandemic need further evaluations.
Title: Evaluating ELISA, Immunofluorescence, and Lateral Flow Assay for SARS-CoV-2 Serologic Assays
Description:
BackgroundThe SARS-CoV-2 outbreak has emerged at the end of 2019.
Aside from the detection of viral genome with specific RT-PCR, there is a growing need for reliable determination of the serological status.
We aimed at evaluating five SARS-CoV-2 serology assays.
MethodsAn in-house immunofluorescence assay (IFA), two ELISA kits (EUROIMMUN® ELISA SARS-CoV-2 IgG and NovaLisa® SARS-CoV-2 IgG and IgM) and two lateral flow assays (T-Tek® SARS-CoV-2 IgG/IgM Antibody Test Kit and Sure Bio-tech® SARS-CoV-2 IgM/IgG Antibody Rapid Test) were compared on 40 serums from RT-PCR-confirmed SARS-CoV-2 infected patients and 10 SARS-CoV-2 RT-PCR negative subjects as controls.
ResultsControl subjects tested negative for SARS-CoV-2 antibodies with all five systems.
Estimated sensitivities varied from 35.
5 to 71.
0% for IgG detection and from 19.
4 to 64.
5% for IgM detection.
For IgG, in-house IFA, EuroImmun, T-Tek and NovaLisa displayed 50–72.
5% agreement with other systems except IFA vs EuroImmun and T-Tek vs NovaLisa.
Intermethod agreement for IgM determination was between 30 and 72.
5%.
DiscussionThe overall intermethod agreement was moderate.
This inconsistency could be explained by the diversity of assay methods, antigens used and immunoglobulin isotype tested.
Estimated sensitivities were low, highlighting the limited value of antibody detection in CoVID-19.
ConclusionComparison of five systems for SARS-CoV-2 IgG and IgM antibodies showed limited sensitivity and overall concordance.
The place and indications of serological status assessment with currently available tools in the CoVID-19 pandemic need further evaluations.

Related Results

The Potential of Medicinal Plants and Bioactive Compounds in the Fight Against COVID-19
The Potential of Medicinal Plants and Bioactive Compounds in the Fight Against COVID-19
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), a novel coronavirus , is causing a serious worldwide COVID-19 pandemic. The emergence of strains with rapid spread and...
The Hidden Problem of Cross-Reactivity: Challenges in HIV Testing During the COVID-19 Era: A Systematic Review
The Hidden Problem of Cross-Reactivity: Challenges in HIV Testing During the COVID-19 Era: A Systematic Review
Abstract Introduction Human immunodeficiency virus (HIV) and Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV2) surface glycoproteins, including shared epitope motifs, sho...
Expanding access to SARS-CoV-2 IgG and IgM serologic testing using fingerstick whole blood, plasma, and rapid lateral flow assays
Expanding access to SARS-CoV-2 IgG and IgM serologic testing using fingerstick whole blood, plasma, and rapid lateral flow assays
AbstractSerologic testing for SARS-CoV-2 antibodies can be used to confirm diagnosis, estimate seroprevalence, screen convalescent plasma donors, and assess vaccine efficacy. Sever...
Performance characteristics of the VIDAS® SARS-COV-2 IgM and IgG serological assays
Performance characteristics of the VIDAS® SARS-COV-2 IgM and IgG serological assays
ABSTRACTThe COVID-19 pandemic, caused by the new severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), continues to spread worldwide. Serological testing for SARS-CoV-2-spe...
Mutations in SARS-CoV
Mutations in SARS-CoV
The coronavirus family is named for the large spike protein molecules found on the pathogen exterior, which give the virus a crown-like appearance, the coronavirus genome is the bi...
Humoral Immune Response to SARS-CoV-2
Humoral Immune Response to SARS-CoV-2
Abstract Objectives Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serology tests are clinically useful to ...
From SARS and MERS CoVs to SARS‐CoV‐2: Moving toward more biased codon usage in viral structural and nonstructural genes
From SARS and MERS CoVs to SARS‐CoV‐2: Moving toward more biased codon usage in viral structural and nonstructural genes
AbstractBackgroundSevere acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) is an emerging disease with fatal outcomes. In this study, a fundamental knowledge gap question is to...

Back to Top