Abstract
Background
Atrial morphological parameters may influence the presence of atrial thrombus, a factor strongly associated with cardiac thromboembolism, independently of those included in the CHA2DS2-VASc risk estimation scale in patients with a history of atrial fibrillation (AF). The aim of our study was to evaluate this possible association by transthoracic echocardiography (TTE).
Methods
Prospective multicenter study including 401 patients with a history of AF, in which a TTE and a transesophageal echocardiogram (TEE) were performed for evaluation of atrial thrombus between 2016-2019. The parameters included in the CHA2DS2-VASc scale, the heart rhythm at the time of the study and the anticoagulant treatment performed, as well as the atrial morphological parameters were collected.
Results
Twenty-three patients (6%) presented with atrial thrombus in TEE. The left atrial area (28 ± 6cm2 vs 33 ± 6cm2; p < 0.001), the presence of AF during the study (83% vs 17%; p = 0.002) and CHA2DS2-VASc (1.7 ± 1.5cm2 vs 3.0 ± 1.3cm2; p < 0.001) were associated with the presence of atrial thrombus. The left atrial area was a diagnostic predictor of atrial thrombus (area under the curve = 73%; p = 0.001): a value >30cm2 presented a sensitivity of 79% and a specificity of 70% to detect its presence. Logistic regression analysis, including heart rhythm during the study and anticoagulant treatment, showed that CHA2DS2-VASc (OR = 1.5; CI95%=1.1-1.9; p = 0.003) and left atrial area >30cm2 (OR = 5.2;CI 95% =1.7-16.0; p = 0.004) were independent predictors of atrial thrombus presence.
Conclusions
The left atrial area is associated with the presence of atrial thrombus in patients with a history of AF independently of the CHA2DS2-VASc scale, heart rhythm during the study, and anticoagulant treatment. This parameter should be evaluated to be included in the cardioembolic risk scales.
Oxford University Press (OUP)
Title: P917 Additional value of atrial parameters evaluated by echocardiography on the scales of cardioembolic risk in atrial fibrillation
Description:
Abstract
Background
Atrial morphological parameters may influence the presence of atrial thrombus, a factor strongly associated with cardiac thromboembolism, independently of those included in the CHA2DS2-VASc risk estimation scale in patients with a history of atrial fibrillation (AF).
The aim of our study was to evaluate this possible association by transthoracic echocardiography (TTE).
Methods
Prospective multicenter study including 401 patients with a history of AF, in which a TTE and a transesophageal echocardiogram (TEE) were performed for evaluation of atrial thrombus between 2016-2019.
The parameters included in the CHA2DS2-VASc scale, the heart rhythm at the time of the study and the anticoagulant treatment performed, as well as the atrial morphological parameters were collected.
Results
Twenty-three patients (6%) presented with atrial thrombus in TEE.
The left atrial area (28 ± 6cm2 vs 33 ± 6cm2; p < 0.
001), the presence of AF during the study (83% vs 17%; p = 0.
002) and CHA2DS2-VASc (1.
7 ± 1.
5cm2 vs 3.
0 ± 1.
3cm2; p < 0.
001) were associated with the presence of atrial thrombus.
The left atrial area was a diagnostic predictor of atrial thrombus (area under the curve = 73%; p = 0.
001): a value >30cm2 presented a sensitivity of 79% and a specificity of 70% to detect its presence.
Logistic regression analysis, including heart rhythm during the study and anticoagulant treatment, showed that CHA2DS2-VASc (OR = 1.
5; CI95%=1.
1-1.
9; p = 0.
003) and left atrial area >30cm2 (OR = 5.
2;CI 95% =1.
7-16.
0; p = 0.
004) were independent predictors of atrial thrombus presence.
Conclusions
The left atrial area is associated with the presence of atrial thrombus in patients with a history of AF independently of the CHA2DS2-VASc scale, heart rhythm during the study, and anticoagulant treatment.
This parameter should be evaluated to be included in the cardioembolic risk scales.
Related Results
RELATIONSHIP BETWEEN ATRIAL FIBRILLATION CARDIOVERSION AND F
RELATIONSHIP BETWEEN ATRIAL FIBRILLATION CARDIOVERSION AND F
Objectives
To investigate the relationship between atrial fibrillation cardioversion and f wave in electrocardiogram, providing an ordinary and noninvasive method...
Adiponectin and Lone atrial fibrillation
Adiponectin and Lone atrial fibrillation
Objective: Lone atrial fibrillation is an idiopathic arrhythmia seen in younger individuals without any secondary disease. Adiponectin is an endogenous adipocytokine that increases...
ASSA13-03-9 Decreased Expression of Small-Conductance Ca2+-Activated K+ Channels SK1, SK2, and SK3 in Patients with Persistent Atrial Fibrillation
ASSA13-03-9 Decreased Expression of Small-Conductance Ca2+-Activated K+ Channels SK1, SK2, and SK3 in Patients with Persistent Atrial Fibrillation
Background
Small-conductance Ca2+-activated K+ channels (SK channels) have been reported involved in atrial fibrillation (AF) as a new ion channel candidates, as ...
Left atrial function assessment by speckle tracking echocardiography in low-risk atrial fibrillation patients
Left atrial function assessment by speckle tracking echocardiography in low-risk atrial fibrillation patients
Objective: To compare the left atrial function utilising speckle tracking echocardiography in patients with low-risk and high-risk non-valvular atrial fibrillation.Methods: The des...
Significance of mitral annulus apparatus morphometry in patients with persistent atrial fibrillation
Significance of mitral annulus apparatus morphometry in patients with persistent atrial fibrillation
Abstract
Background
Few data about mitral valve apparatus components deformation in patients with persistent atrial fibrillation...
Left atrial strain parameters are able to predict presence of atrial fibrillation
Left atrial strain parameters are able to predict presence of atrial fibrillation
Abstract
Background
Three-dimensional speckle-tracking echocardiography allows evaluation of left atrial function, left atrial f...
Diagnostic accuracy of an oscillometric blood pressure monitor for atrial fibrillation screening
Diagnostic accuracy of an oscillometric blood pressure monitor for atrial fibrillation screening
Objective
Atrial fibrillation is the most common arrhythmia of clinical significance and hypertension is one of its major risk factors. This study aimed to evaluate the...
Left atrial volumes and associated stroke subtypes
Left atrial volumes and associated stroke subtypes
Abstract
Background
Cardio embolism and cerebrovascular atherosclerosis are two major mechanisms of stroke. Studies investigating associations be...