Javascript must be enabled to continue!
Enhancement Drip Dose Infusion Accuracy Based on Optocoupler and Microcontroller Sensor
View through CrossRef
Setting the speed of infusion drops in a manual manner is by adjusting the clamp on the infusion set, where the nurse must count the number of infusion drops in the chamber at the same time as looking at the time on the watch. This makes the setting is subjective and cannot be shown with numbers. In addition, nurses cannot monitor the infusion rate continuously. Therefore, it is necessary to enhancement the accuracy of giving infusion drops so that they can be objective and can be shown with numbers and monitor continuously. This enhancement in accuracy is done by making a instrument with an optocoupler to detect infusion drops. For processing uses an arduino microcontroller to be the speed and the volume of infusion and detects changes in the rate of infusion drops significantly. And for the display uses a OLED display and a buzzer as an indicator. The results of this instrument, it can be seen that the optocoupler can detect infusion drops in the infusion set properly. This good sensor reading has implications for accurate readings of the infusion drop rate and infusion drop volume. This enhancement in accuracy is not only for the macro drip (20 drops/cc) but also for the micro drip (60 drops/cc). The accuracy of volume readings ranges from 95-99% for the macro drip and 94.5-97% with the micro drip. And for speed accuracy ranges from 92.37-98.46%. Based from the results of this test, enhancement the accuracy of the infusion drip dose administration can be done by making a patient infusion drip dose calculator. This equipment uses an optocoupler sensor, arduino microcontroller, OLED display and buzzer. With the use of this instrument, nurses can be more accurate in regulating the rate of infusion drops given to patients and can monitor it continuously if there is a significant change in infusion rate.
Title: Enhancement Drip Dose Infusion Accuracy Based on Optocoupler and Microcontroller Sensor
Description:
Setting the speed of infusion drops in a manual manner is by adjusting the clamp on the infusion set, where the nurse must count the number of infusion drops in the chamber at the same time as looking at the time on the watch.
This makes the setting is subjective and cannot be shown with numbers.
In addition, nurses cannot monitor the infusion rate continuously.
Therefore, it is necessary to enhancement the accuracy of giving infusion drops so that they can be objective and can be shown with numbers and monitor continuously.
This enhancement in accuracy is done by making a instrument with an optocoupler to detect infusion drops.
For processing uses an arduino microcontroller to be the speed and the volume of infusion and detects changes in the rate of infusion drops significantly.
And for the display uses a OLED display and a buzzer as an indicator.
The results of this instrument, it can be seen that the optocoupler can detect infusion drops in the infusion set properly.
This good sensor reading has implications for accurate readings of the infusion drop rate and infusion drop volume.
This enhancement in accuracy is not only for the macro drip (20 drops/cc) but also for the micro drip (60 drops/cc).
The accuracy of volume readings ranges from 95-99% for the macro drip and 94.
5-97% with the micro drip.
And for speed accuracy ranges from 92.
37-98.
46%.
Based from the results of this test, enhancement the accuracy of the infusion drip dose administration can be done by making a patient infusion drip dose calculator.
This equipment uses an optocoupler sensor, arduino microcontroller, OLED display and buzzer.
With the use of this instrument, nurses can be more accurate in regulating the rate of infusion drops given to patients and can monitor it continuously if there is a significant change in infusion rate.
Related Results
Research on Underground Drip Irrigation and Soil Redistribution - Take Heshan District of Yiyang City as an Example
Research on Underground Drip Irrigation and Soil Redistribution - Take Heshan District of Yiyang City as an Example
Abstract: The drip flow and the buried depth of drip irrigation zone are not only important parameters of subsurface irrigation design and operation management, but also important ...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Modern approaches to infusion therapy in pediatrics and chemotherapy
Modern approaches to infusion therapy in pediatrics and chemotherapy
Background. Systems for intravenous administration of blood products and drugs are divided into the systems for transfusion (pore diameter – 114-200 μm) and systems for infusion (p...
Response of indigenous low cost smart fertigation system on growth, physiology, root characters and yield of groundnut (Arachis hypogaea L.)
Response of indigenous low cost smart fertigation system on growth, physiology, root characters and yield of groundnut (Arachis hypogaea L.)
Precise application of nutrients and water in groundnut ensures optimal plant growth, enhances yield and quality and minimizes resource wastage. It promotes sustainable farming by ...
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED]Rhino XL Reviews, NY USA: Studies show that testosterone levels in males decrease constantly with growing age. There are also many other problems that males face due ...
Risk assessment method for emitter clogging in drip irrigation systems
Risk assessment method for emitter clogging in drip irrigation systems
Abstract
Risk assessment of drip irrigation system emitter clogging is critical for the system's safe operation. In this paper, the emitter clogging risk and the calculatio...
A Multi-Center Time Study of Home Infusion Pharmacist Professional Services for Specialty Infusion Medications
A Multi-Center Time Study of Home Infusion Pharmacist Professional Services for Specialty Infusion Medications
Introduction
Specialty infusion and injection medications are key growth areas in home infusion services. According to the National Home Infusion Association (NHIA), over 315,000 s...
The Effect of Health Education on Infusion of Patients on Maintenance of Infusion Drops at Citama Hospital in 2021
The Effect of Health Education on Infusion of Patients on Maintenance of Infusion Drops at Citama Hospital in 2021
This study aims to identify the characteristics of patients who are infusions, before and after infusion health education is carried out on patients for the maintenance of infusion...

