Enhancement Drip Dose Infusion Accuracy Based on Optocoupler and Microcontroller Sensor

View through CrossRef
Setting the speed of infusion drops in a manual manner is by adjusting the clamp on the infusion set, where the nurse must count the number of infusion drops in the chamber at the same time as looking at the time on the watch. This makes the setting is subjective and cannot be shown with numbers. In addition, nurses cannot monitor the infusion rate continuously. Therefore, it is necessary to enhancement the accuracy of giving infusion drops so that they can be objective and can be shown with numbers and monitor continuously. This enhancement in accuracy is done by making a instrument with an optocoupler to detect infusion drops. For processing uses an arduino microcontroller to be the speed and the volume of infusion and detects changes in the rate of infusion drops significantly. And for the display uses a OLED display and a buzzer as an indicator. The results of this instrument, it can be seen that the optocoupler can detect infusion drops in the infusion set properly. This good sensor reading has implications for accurate readings of the infusion drop rate and infusion drop volume. This enhancement in accuracy is not only for the macro drip (20 drops/cc) but also for the micro drip (60 drops/cc). The accuracy of volume readings ranges from 95-99% for the macro drip and 94.5-97% with the micro drip. And for speed accuracy ranges from 92.37-98.46%. Based from the results of this test, enhancement the accuracy of the infusion drip dose administration can be done by making a patient infusion drip dose calculator. This equipment uses an optocoupler sensor, arduino microcontroller, OLED display and buzzer. With the use of this instrument, nurses can be more accurate in regulating the rate of infusion drops given to patients and can monitor it continuously if there is a significant change in infusion rate.
Title: Enhancement Drip Dose Infusion Accuracy Based on Optocoupler and Microcontroller Sensor
Description:
Setting the speed of infusion drops in a manual manner is by adjusting the clamp on the infusion set, where the nurse must count the number of infusion drops in the chamber at the same time as looking at the time on the watch.
This makes the setting is subjective and cannot be shown with numbers.
In addition, nurses cannot monitor the infusion rate continuously.
Therefore, it is necessary to enhancement the accuracy of giving infusion drops so that they can be objective and can be shown with numbers and monitor continuously.
This enhancement in accuracy is done by making a instrument with an optocoupler to detect infusion drops.
For processing uses an arduino microcontroller to be the speed and the volume of infusion and detects changes in the rate of infusion drops significantly.
And for the display uses a OLED display and a buzzer as an indicator.
The results of this instrument, it can be seen that the optocoupler can detect infusion drops in the infusion set properly.
This good sensor reading has implications for accurate readings of the infusion drop rate and infusion drop volume.
This enhancement in accuracy is not only for the macro drip (20 drops/cc) but also for the micro drip (60 drops/cc).
The accuracy of volume readings ranges from 95-99% for the macro drip and 94.
5-97% with the micro drip.
And for speed accuracy ranges from 92.
37-98.
46%.
Based from the results of this test, enhancement the accuracy of the infusion drip dose administration can be done by making a patient infusion drip dose calculator.
This equipment uses an optocoupler sensor, arduino microcontroller, OLED display and buzzer.
With the use of this instrument, nurses can be more accurate in regulating the rate of infusion drops given to patients and can monitor it continuously if there is a significant change in infusion rate.

Related Results

Research on Underground Drip Irrigation and Soil Redistribution - Take Heshan District of Yiyang City as an Example
Research on Underground Drip Irrigation and Soil Redistribution - Take Heshan District of Yiyang City as an Example
Abstract: The drip flow and the buried depth of drip irrigation zone are not only important parameters of subsurface irrigation design and operation management, but also important ...
Modern approaches to infusion therapy in pediatrics and chemotherapy
Modern approaches to infusion therapy in pediatrics and chemotherapy
Background. Systems for intravenous administration of blood products and drugs are divided into the systems for transfusion (pore diameter – 114-200 μm) and systems for infusion (p...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED]Rhino XL Reviews, NY USA: Studies show that testosterone levels in males decrease constantly with growing age. There are also many other problems that males face due ...
[RETRACTED] Gro-X Male Enhancement | Safely Grow Your Size, Sex Drive v1
[RETRACTED] Gro-X Male Enhancement | Safely Grow Your Size, Sex Drive v1
[RETRACTED]Gro-X Male Enhancement Reviews - Is It Worth the Money? Scam or Legit? Gro-X Male Enhancement Male health is very important, especially for a couple. Low sperm count an...
Moog Type Syringe Pump Repair Aitecs 2016 Advance d Sryinge Pump
Moog Type Syringe Pump Repair Aitecs 2016 Advance d Sryinge Pump
Syringe Pump is one of the medical equipment that functions to insert medicinal liquid into patients for a certain period of time regularly. The Syringe Pump cannot function as it ...
Risk assessment method for emitter clogging in drip irrigation systems
Risk assessment method for emitter clogging in drip irrigation systems
Abstract Risk assessment of drip irrigation system emitter clogging is critical for the system's safe operation. In this paper, the emitter clogging risk and the calculatio...

Back to Top