Structural and functional integrity of decontaminated N95 respirators: Experimental results
View through CrossRef
With the recent emergence of highly transmissible variants of the novel coronavirus SARS-CoV-2, the demand for N95 respirators is expected to remain high. The extensive use of N95 respirators by the public is susceptible to demand‐supply gaps and raises concern about their disposal, threatening the environment with a new kind of plastic pollution. Herein, we investigated the filtration performance of the N95 respirator by specifically analyzing the structure in the key filtration layers of meltblown nonwoven after decontamination with one and five cycles of liquid hydrogen peroxide, ultraviolet radiation, moist heat, and aqueous soap solution treatments. With the aid of X-ray microcomputed tomography (microCT) analysis, the local structural heterogeneity of the meltblown nonwoven has been unfolded and subsequently correlated with their filtration performance at a face velocity that matched with speaking conditions (∼3.89 m/s). The filtration efficiency results of the N95 respirator remain unaltered after performing one cycle of treatment modalities (except autoclave).
Title: Structural and functional integrity of decontaminated N95 respirators: Experimental results
Description:
With the recent emergence of highly transmissible variants of the novel coronavirus SARS-CoV-2, the demand for N95 respirators is expected to remain high.
The extensive use of N95 respirators by the public is susceptible to demand‐supply gaps and raises concern about their disposal, threatening the environment with a new kind of plastic pollution.
Herein, we investigated the filtration performance of the N95 respirator by specifically analyzing the structure in the key filtration layers of meltblown nonwoven after decontamination with one and five cycles of liquid hydrogen peroxide, ultraviolet radiation, moist heat, and aqueous soap solution treatments.
With the aid of X-ray microcomputed tomography (microCT) analysis, the local structural heterogeneity of the meltblown nonwoven has been unfolded and subsequently correlated with their filtration performance at a face velocity that matched with speaking conditions (∼3.
89 m/s).
The filtration efficiency results of the N95 respirator remain unaltered after performing one cycle of treatment modalities (except autoclave).
Related Results
Decontamination of filtering facepiece respirators in primary care using medical autoclave
Decontamination of filtering facepiece respirators in primary care using medical autoclave
AbstractObjectiveThere are widespread shortages of personal protective equipment as a result of the coronavirus disease 2019 (COVID-19) pandemic. Reprocessing filtering facepiece r...
Computer-Aided Customized Shape Design of an N95 Filtering Facepiece Respirator
Computer-Aided Customized Shape Design of an N95 Filtering Facepiece Respirator
A respirator protects its user by sealing the user’s face and filtering hazardous particles from environment. However, faceseal leakages of users-respirators always happen. First, ...
Effective decontamination and multiplication of Croton membranaceus in vitro
Effective decontamination and multiplication of Croton membranaceus in vitro
Abstract. Adukonu IA, Ayeh KO, Acheampong E. 2022. Effective decontamination and multiplication of Croton membranaceus in vitro. Cell Biol Dev 6: 68-81. Croton membranaceus Müll. A...
Knowledge, Attitudes, Practices, and Perceived Usability of Respirators Among Thai Healthcare Personnel During the COVID-19 Pandemic
Knowledge, Attitudes, Practices, and Perceived Usability of Respirators Among Thai Healthcare Personnel During the COVID-19 Pandemic
Background: Respirators are essential for protecting healthcare personnel (HCPs) from airborne infections, and were particularly valuable during the COVID-19 pandemic. However, kno...
Physiologic Effects and Symptoms Associated with Extended-Use Medical Mask and N95 Respirators
Physiologic Effects and Symptoms Associated with Extended-Use Medical Mask and N95 Respirators
Abstract
Objectives
Compliance and tolerance of facemasks for extended periods are legitimate concerns. The goal of this study w...
Knowledge and Awareness of Masks and N95 Respirators Used for COVID-19 Prevention Among Chemical Engineering Students at Al-Balqa Applied University, Jordan
Knowledge and Awareness of Masks and N95 Respirators Used for COVID-19 Prevention Among Chemical Engineering Students at Al-Balqa Applied University, Jordan
Background and Objectives: On March 11, the World Health Organization stated coronavirus disease 2019 (COVID-19) was a global pandemic; the rapid and extended spread of the COVID-1...
A Study of Strategies to Achieve Proper N95 Respirator Use by Regular N95 Respirator
A Study of Strategies to Achieve Proper N95 Respirator Use by Regular N95 Respirator
OBJECTIVE To explore different strategies for achieving proper use of N95 respirators by hospital staff, including viewing the donning process in a mirror, receiving assistance fr...
Assessment of N95 respirator for reuse after sterilization: filtration efficacy, breathing resistance, quality factor, chemical structure and surface charge density
Assessment of N95 respirator for reuse after sterilization: filtration efficacy, breathing resistance, quality factor, chemical structure and surface charge density
Abstract
In the present ongoing pandemic, the N95 respirator is an essential protective barrier to suppress the spread of the SARS-Cov-2 virus an...