Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Assessment of N95 respirator for reuse after sterilization: filtration efficacy, breathing resistance, quality factor, chemical structure and surface charge density

View through CrossRef
Abstract In the present ongoing pandemic, the N95 respirator is an essential protective barrier to suppress the spread of the SARS-Cov-2 virus and protect the frontline worker from exposure. The N95 respirators are meant for single usage; however, they can be used after decontamination in-light of the economy and shortfall in availability. At this juncture, the respirators performance after various types of sterilization and usage condition is required to be analyzed in detail. With this motto, this work has proceeded. The filtration efficiency, pressure drop, and quality factor of the respirator are evaluated for two face velocities (5.8 and 26.4 cm/s) following different sterilization methods. Sterilization techniques used here are dry air oven heating, gamma irradiation, and immersing in a 10% concentration of liquid hydrogen peroxide. The particle filtration performance and electrostatic surface charge density measurement are used to determine the facemasks efficacy after sterilization. The methods recommended to sterilize N95 masks without affecting their performance are (i) using dry air heat at 80°C and (ii) H 2 O 2 soaking. The highest reduction in filtration efficiency is observed to be 30-35% after gamma irradiation due to a change in the electrostatic properties of the respirator layers. However, the filtration efficiency does not change significantly for other sterilization methods despite a change in charge density, but there is no direct correlation with filtration efficiency. Electrostatic charge measurement of the filtration layer is a crucial indicator of filtration efficiency degradation. Policymakers can use these data during potential future N95 shortage to assess the viability of sterilization methods.
Title: Assessment of N95 respirator for reuse after sterilization: filtration efficacy, breathing resistance, quality factor, chemical structure and surface charge density
Description:
Abstract In the present ongoing pandemic, the N95 respirator is an essential protective barrier to suppress the spread of the SARS-Cov-2 virus and protect the frontline worker from exposure.
The N95 respirators are meant for single usage; however, they can be used after decontamination in-light of the economy and shortfall in availability.
At this juncture, the respirators performance after various types of sterilization and usage condition is required to be analyzed in detail.
With this motto, this work has proceeded.
The filtration efficiency, pressure drop, and quality factor of the respirator are evaluated for two face velocities (5.
8 and 26.
4 cm/s) following different sterilization methods.
Sterilization techniques used here are dry air oven heating, gamma irradiation, and immersing in a 10% concentration of liquid hydrogen peroxide.
The particle filtration performance and electrostatic surface charge density measurement are used to determine the facemasks efficacy after sterilization.
The methods recommended to sterilize N95 masks without affecting their performance are (i) using dry air heat at 80°C and (ii) H 2 O 2 soaking.
The highest reduction in filtration efficiency is observed to be 30-35% after gamma irradiation due to a change in the electrostatic properties of the respirator layers.
However, the filtration efficiency does not change significantly for other sterilization methods despite a change in charge density, but there is no direct correlation with filtration efficiency.
Electrostatic charge measurement of the filtration layer is a crucial indicator of filtration efficiency degradation.
Policymakers can use these data during potential future N95 shortage to assess the viability of sterilization methods.

Related Results

Forced Sterilization
Forced Sterilization
Photo by Renè Müller on Unsplash INTRODUCTION Forced sterilization of women around the globe is a human rights violation and bioethical concern. In the past, countries enacted laws...
A Study of Strategies to Achieve Proper N95 Respirator Use by Regular N95 Respirator
A Study of Strategies to Achieve Proper N95 Respirator Use by Regular N95 Respirator
OBJECTIVE To explore different strategies for achieving proper use of N95 respirators by hospital staff, including viewing the donning process in a mirror, receiving assistance fr...
Adjusting a commonly used respirator pressure drop equation for use with modern respirators
Adjusting a commonly used respirator pressure drop equation for use with modern respirators
Millions of workers in the United States require the use of a respirator while at work. Occupational inhalation hazards have the potential to cause respiratory diseases. Wearing ...
STERILIZATION: A PREREQUISITE IN MEDICAL DIAGNOSTICS
STERILIZATION: A PREREQUISITE IN MEDICAL DIAGNOSTICS
Sterilization is a critical process with wide-ranging applications in healthcare, pharmaceuticals, food production, and laboratory research. Its primary objective is the complete e...
Pregnancy after Tubal Sterilization
Pregnancy after Tubal Sterilization
Objectives: In our study, we have tried to evaluate the causative factors for sterilization failure and also to discuss preventive measures to avoid maternal morbidities and unwant...
Analysis of Fluid Flow on the N95 Facepiece Filtration Layers
Analysis of Fluid Flow on the N95 Facepiece Filtration Layers
Due to the general confusion over the mask's efficiency against COVID-19 virus droplets, professionals and the public may find it difficult to stop the disease from spreading. This...

Back to Top