DistoX calibration tools and the need for calibration checking
View through CrossRef
For proper cave surveying using DistoX, the device needs to be calibrated with adequate accuracy. Calibrating does not require any tools; but, tools to make calibration easier have been developed. Theoretical consideration shows that the use of certain tools enables one to introduce a type of calibration error that goes undetected by the calibration software. In this study, the existence of such errors is experimentally confirmed and their magnitude is estimated. It is demonstrated to be crucial that the DistoX is calibrated and that the calibration is valid, that is, that the device has not changed since it was last calibrated. No part of the DistoX must have moved or changed its magnetization since calibration, not even the battery. The calibration method used and the quality of the resulting calibration are important too. It is highly recommended that the DistoX be checked immediately before surveying a cave and thus avoid the possibility of using an uncalibrated, not validly calibrated, or poorly calibrated device. To complete the check, a few survey shots are measured multiple times with the device at different roll angles, and the back shot of one of the shots is measured. If the device is properly calibrated, the measurements will agree with each other within the acceptable measurement error. This is not the case for a device that is not properly calibrated.
The Research Center of the Slovenian Academy of Sciences and Arts / Znanstvenoraziskovalni center Slovenske akademije znanosti in umetnosti (ZRC SAZU)
Title: DistoX calibration tools and the need for calibration checking
Description:
For proper cave surveying using DistoX, the device needs to be calibrated with adequate accuracy.
Calibrating does not require any tools; but, tools to make calibration easier have been developed.
Theoretical consideration shows that the use of certain tools enables one to introduce a type of calibration error that goes undetected by the calibration software.
In this study, the existence of such errors is experimentally confirmed and their magnitude is estimated.
It is demonstrated to be crucial that the DistoX is calibrated and that the calibration is valid, that is, that the device has not changed since it was last calibrated.
No part of the DistoX must have moved or changed its magnetization since calibration, not even the battery.
The calibration method used and the quality of the resulting calibration are important too.
It is highly recommended that the DistoX be checked immediately before surveying a cave and thus avoid the possibility of using an uncalibrated, not validly calibrated, or poorly calibrated device.
To complete the check, a few survey shots are measured multiple times with the device at different roll angles, and the back shot of one of the shots is measured.
If the device is properly calibrated, the measurements will agree with each other within the acceptable measurement error.
This is not the case for a device that is not properly calibrated.
Related Results
Model-checking ecological state-transition graphs
Model-checking ecological state-transition graphs
Abstract
Model-checking is a methodology developed in computer science to automatically assess the dynamics of discrete systems, by checking if a system modelled as...
Evolution of a course on model checking for practical applications
Evolution of a course on model checking for practical applications
Although model checking is expected as a practical formal verification approach for its automatic nature, it still suffers from difficulties in writing the formal descriptions to b...
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
Clock monitoring is associated with age-related decline in time-based prospective memory
Clock monitoring is associated with age-related decline in time-based prospective memory
AbstractIn laboratory time-based prospective memory tasks, older adults typically perform worse than younger adults do. It has been suggested that less frequent clock checking due ...
A calibration method combining hand-eye calibration and TCP calibration
A calibration method combining hand-eye calibration and TCP calibration
Abstract
Robots' traditional Tool Center Point (TCP) calibration and hand-eye calibration are implemented independently, which is likely to generate large cumulative errors...
Consistent Calibration of VIRR Reflective Solar Channels Onboard FY-3A, FY-3B, and FY-3C Using a Multisite Calibration Method
Consistent Calibration of VIRR Reflective Solar Channels Onboard FY-3A, FY-3B, and FY-3C Using a Multisite Calibration Method
The FengYun-3 (FY-3) Visible Infrared Radiometer (VIRR), along with its predecessor, the Multispectral Visible Infrared Scanning Radiometer (MVISR), onboard the FY-1C and FY-1D, ha...
Efficient and Effective Gas Sensor Calibration with Randomized Gas Mixtures
Efficient and Effective Gas Sensor Calibration with Randomized Gas Mixtures
Introduction
The selective quantification of target gases in complex mixtures is an important part of numerous applications of chemical gas sensors. ...
A distributed model to expand the reach of drug checking
A distributed model to expand the reach of drug checking
Purpose
While there is increasing interest in implementing drug checking within overdose prevention, we must also consider how to scale-up these responses so that they have signifi...