A reference facility for the comparison of CO2 in Air isotope ratio standards

View through CrossRef
The commercial development of laser-based instruments over the last decade that can measure real-time isotopic ratio variations of greenhouse gases, and notably CO2, has allowed their application across a wide range of scientific and technical disciplines. Precise measurements can be achieved, and appropriate calibration strategies [1] and standards need to be applied to achieve accurate results and consistency with traditional mass spectrometric measurement methods. For CO2, calibration strategies can be based on using CO2 in air standards with the same isotopic ratios but containing different amount fractions, or the same amount fraction and different isotope ratios. This has resulted in the availability of calibration standards containing different isotope ratios at different amount fractions, which may or may not contain nitrous oxide. An international comparison programme at the BIPM (BIPM.QM-K4) is in development to demonstrate the equivalence of such standards, which would allow them to be used interchangeably by operators.The BIPM’s comparison facility is based on a dual inlet isotope ratio mass spectrometer with a custom built (BIPM) Air Trapping system (BAT) to extract CO2 from air mixtures using cryogenic separation for determination of δ13Cand δ18O-CO2, with a correction for the N2O present in the sample. A procedure for regularly determining the relative ionization efficiency of N2O in relation to CO2 has been developed and is applied as a function of the amount fraction of N2O in the sample. Metrological traceability is achieved through a hierarchy of low-pressure CO2 standards with δ13C values nominally at -1 ‰, -35 ‰ and -43 ‰, calibrated on the VPDB scale via IAEA 603 carbonate standard material. Initial validation of the performance of the facility has been performed with the extraction of CO2 from gas mixtures within the range of 380 μmol mol−1 to 800 μmol mol−1 and δ13C and δ18O-CO2 values from 1 ‰ to -43 ‰ and -7 ‰  to -35 ‰, respectively. The method demonstrates excellent reproducibility, with standard deviations of 0.005% and 0.05%. for δ13C  and δ18O-CO2, respectively. In addition, the robustness of the N2O correction has been demonstrated by comparing δ13C  and δ18O-CO2 values from standards produced from the same CO2 source gas but at differing amount fractions. The performance and validation of the facility will be described. [1] Flores, E., Viallon, J., Moussay, P., Griffith, D. W. T. & Wielgosz, R. I. Calibration strategies for FT-IR and other isotope ratio infrared spectrometer instruments for accurate δ13C and δ18O measurements of CO2 in air. Anal. Chem. 89, 3648–3655 (2017).
Title: A reference facility for the comparison of CO2 in Air isotope ratio standards
Description:
The commercial development of laser-based instruments over the last decade that can measure real-time isotopic ratio variations of greenhouse gases, and notably CO2, has allowed their application across a wide range of scientific and technical disciplines.
Precise measurements can be achieved, and appropriate calibration strategies [1] and standards need to be applied to achieve accurate results and consistency with traditional mass spectrometric measurement methods.
For CO2, calibration strategies can be based on using CO2 in air standards with the same isotopic ratios but containing different amount fractions, or the same amount fraction and different isotope ratios.
This has resulted in the availability of calibration standards containing different isotope ratios at different amount fractions, which may or may not contain nitrous oxide.
An international comparison programme at the BIPM (BIPM.
QM-K4) is in development to demonstrate the equivalence of such standards, which would allow them to be used interchangeably by operators.
The BIPM’s comparison facility is based on a dual inlet isotope ratio mass spectrometer with a custom built (BIPM) Air Trapping system (BAT) to extract CO2 from air mixtures using cryogenic separation for determination of δ13Cand δ18O-CO2, with a correction for the N2O present in the sample.
A procedure for regularly determining the relative ionization efficiency of N2O in relation to CO2 has been developed and is applied as a function of the amount fraction of N2O in the sample.
Metrological traceability is achieved through a hierarchy of low-pressure CO2 standards with δ13C values nominally at -1 ‰, -35 ‰ and -43 ‰, calibrated on the VPDB scale via IAEA 603 carbonate standard material.
Initial validation of the performance of the facility has been performed with the extraction of CO2 from gas mixtures within the range of 380 μmol mol−1 to 800 μmol mol−1 and δ13C and δ18O-CO2 values from 1 ‰ to -43 ‰ and -7 ‰  to -35 ‰, respectively.
The method demonstrates excellent reproducibility, with standard deviations of 0.
005% and 0.
05%.
for δ13C  and δ18O-CO2, respectively.
In addition, the robustness of the N2O correction has been demonstrated by comparing δ13C  and δ18O-CO2 values from standards produced from the same CO2 source gas but at differing amount fractions.
The performance and validation of the facility will be described.
 [1] Flores, E.
, Viallon, J.
, Moussay, P.
, Griffith, D.
W.
T.
& Wielgosz, R.
I.
Calibration strategies for FT-IR and other isotope ratio infrared spectrometer instruments for accurate δ13C and δ18O measurements of CO2 in air.
Anal.
Chem.
89, 3648–3655 (2017).

Related Results

Design And Operation Of The Levelland Unit CO2 Injection Facility
Design And Operation Of The Levelland Unit CO2 Injection Facility
Abstract The Levelland CO2 Facility provides CO2 storageand handling capacity for the five CO2 injection pilots located in the Levelland Unit. Facilities pilots l...
New standards for isotope measurements of CO2 for atmospheric and biogeoscience applications
New standards for isotope measurements of CO2 for atmospheric and biogeoscience applications
Progress in the development of pure CO2 gas standards for δ13C, δ18O and Δ47 measurements as well as CO2 in air gas standards (with mole fractions in the range 350 µmol/mol to 800 ...
Rapid Large-scale Trapping of CO2 via Dissolution in US Natural CO2 Reservoirs
Rapid Large-scale Trapping of CO2 via Dissolution in US Natural CO2 Reservoirs
Naturally occurring CO2 reservoirs across the USA are critical natural analogues of long-term CO2 storage in the subsurface over geological timescales and provide valuable insights...
Resolving the Hf-Nd paradox of early Earth crust-mantle evolution
Resolving the Hf-Nd paradox of early Earth crust-mantle evolution
<p>One of the fundamental tenets of geochemistry is that the Earth’s crust has been extracted from the mantle creating a crustal reservoir enriched&...
Impact of CCUS Impurities on Dense Phase CO2 Pipeline Surface Engineering Design
Impact of CCUS Impurities on Dense Phase CO2 Pipeline Surface Engineering Design
Abstract Numerous CO2 injection pipeline applications have been developed and implemented in the past decades in the UAE and all around the globe. Transporting the C...
Evaluation of Kaolinite and activated carbon performance for CO2 capture
Evaluation of Kaolinite and activated carbon performance for CO2 capture
Global climate change is one of the major threats facing the world today and can be due to increased atmospheric concentrations of greenhouse gases (GHGs), such as carbon dioxide (...
Quantifying CO2 Dissolution and Mineralisation Using Inherent Isotope Ratios at the CarbFix2 Project, Iceland
Quantifying CO2 Dissolution and Mineralisation Using Inherent Isotope Ratios at the CarbFix2 Project, Iceland
Injection of CO2 into reactive rocks for permanent fixation into new minerals guarantees storage security1. The leading demonstration of this technology is the CarbFix2 project, in...
Improving calibrations of in-house water isotope standards using CRDS and OA-CRDS: memory effects versus drift
Improving calibrations of in-house water isotope standards using CRDS and OA-CRDS: memory effects versus drift
<p>The isotope composition of rainfall provides information on the initial isotope composition of the moisture source, conditions during evaporation and condensation ...

Back to Top