Javascript must be enabled to continue!
Haemodynamic stability and incidence of adverse events during tracheal intubation without neuromuscular blockade: comparison of clinical versus bispectral-index monitored depth of anaesthesia
View through CrossRef
Background: Haemodynamic stability during intubation is influenced by sympathetic response to laryngoscopy and intubation. Furthermore, the incidence of adverse events during intubation without NMB warrants further investigation. BIS-guided anaesthesia has been associated with improved haemodynamic outcomes compared to clinical monitoring alone. Despite these advantages, the utility of BIS monitoring during intubation without NMB remains underexplored.
Methods: This was a randomised, single-blind, controlled clinical study conducted in the Jos university teaching hospital, Jos, Nigeria, among 56 children aged 2 to 6 years with ASA I and II scheduled for adenotonsillectomy. Patients were randomised into two groups, B and C, with patients in group B receiving BIS monitoring while those in group C received clinical monitoring for the depth of anaesthesia with sevoflurane and without a neuromuscular blocking agent. Haemodynamic changes and adverse events associated with laryngoscopy were noted. Data was analysed using SPSS with students’ t test and chi-square test being the statistical tests utilised, and the level of significance set at p=0.05.
Results: Systolic blood pressures were slightly higher in group C than group B. Diastolic blood pressures were slightly higher in group B than group C, while differences in mean arterial pressure between group B and group C were not statistically significant (p=0.10). Adverse events were only found in group C, with 10.7% of patients developing laryngospasm.
Conclusions: The monitoring of inhalational induction using clinical signs is an acceptable alternative to BIS and can be used in the absence of BIS.
Title: Haemodynamic stability and incidence of adverse events during tracheal intubation without neuromuscular blockade: comparison of clinical versus bispectral-index monitored depth of anaesthesia
Description:
Background: Haemodynamic stability during intubation is influenced by sympathetic response to laryngoscopy and intubation.
Furthermore, the incidence of adverse events during intubation without NMB warrants further investigation.
BIS-guided anaesthesia has been associated with improved haemodynamic outcomes compared to clinical monitoring alone.
Despite these advantages, the utility of BIS monitoring during intubation without NMB remains underexplored.
Methods: This was a randomised, single-blind, controlled clinical study conducted in the Jos university teaching hospital, Jos, Nigeria, among 56 children aged 2 to 6 years with ASA I and II scheduled for adenotonsillectomy.
Patients were randomised into two groups, B and C, with patients in group B receiving BIS monitoring while those in group C received clinical monitoring for the depth of anaesthesia with sevoflurane and without a neuromuscular blocking agent.
Haemodynamic changes and adverse events associated with laryngoscopy were noted.
Data was analysed using SPSS with students’ t test and chi-square test being the statistical tests utilised, and the level of significance set at p=0.
05.
Results: Systolic blood pressures were slightly higher in group C than group B.
Diastolic blood pressures were slightly higher in group B than group C, while differences in mean arterial pressure between group B and group C were not statistically significant (p=0.
10).
Adverse events were only found in group C, with 10.
7% of patients developing laryngospasm.
Conclusions: The monitoring of inhalational induction using clinical signs is an acceptable alternative to BIS and can be used in the absence of BIS.
Related Results
Intubating Conditions and Tracheal Intubation at First Attempt Without Neuromuscular Blockade Using Sevoflurane: Comparison of Clinical Versus Bispectral Index Monitored Depth of Anaesthesia
Intubating Conditions and Tracheal Intubation at First Attempt Without Neuromuscular Blockade Using Sevoflurane: Comparison of Clinical Versus Bispectral Index Monitored Depth of Anaesthesia
Tracheal intubation, which is typically made possible by neuromuscular blocking agents, is an essential part of airway management in critical care and anaesthesia. To lessen relate...
TIME TO LOSS OF CONSCIOUSNESS AND TRACHEAL INTUBATION WITHOUT NEUROMUSCULAR BLOCKADE USING SEVOFLURANE: A COMPARATIVE ANALYSIS OF CLINICAL VERSUS BISPECTRAL INDEX MONITORED DEPTH OF ANAESTHESIA
TIME TO LOSS OF CONSCIOUSNESS AND TRACHEAL INTUBATION WITHOUT NEUROMUSCULAR BLOCKADE USING SEVOFLURANE: A COMPARATIVE ANALYSIS OF CLINICAL VERSUS BISPECTRAL INDEX MONITORED DEPTH OF ANAESTHESIA
Endotracheal intubation is the gold standard for airway management that establishes a definitive airway. Because of the problems associated with the use of neuromuscular blockade, ...
Treatment of cicatricial tracheal stenosis and tracheoesophageal fistula in patients with COVID-19 pneumonia
Treatment of cicatricial tracheal stenosis and tracheoesophageal fistula in patients with COVID-19 pneumonia
Objective. To describe treatment of cicatricial tracheal stenosis and tracheoesophageal fistula in patients with COVID-19 pneumonia. Material and methods. There were 91 patients wi...
A canine model of tracheal stenosis induced by cuffed endotracheal intubation
A canine model of tracheal stenosis induced by cuffed endotracheal intubation
AbstractPostintubation tracheal stenosis is a complication of endotracheal intubation. The pathological mechanism and risk factors for endotracheal intubation-induced tracheal sten...
Comparison of Airtraq® Laryngoscope, Bonfils Endoscope and Fiberoptic Bronchoscope for Awake Tracheal Intubation: A Randomized, Controlled Trial
Comparison of Airtraq® Laryngoscope, Bonfils Endoscope and Fiberoptic Bronchoscope for Awake Tracheal Intubation: A Randomized, Controlled Trial
Over the last decades several indirect laryngoscopes have been developed to provide a significant better glottic view and improved the success rate in difficult intubations. Some c...
A spray-as-you-go airway topical anesthesia attenuates cardiovascular responses for double-lumen tube tracheal intubation
A spray-as-you-go airway topical anesthesia attenuates cardiovascular responses for double-lumen tube tracheal intubation
Abstract
Background: The spray-as-you-go airway topical anesthesia and nerve block technique are commonly used in awake tracheal intubation. However, their effects have not...
Frequency of tracheal intubation associated adverse events and contributing factors in the Pediatric Intensive Care Unit (PICU).
Frequency of tracheal intubation associated adverse events and contributing factors in the Pediatric Intensive Care Unit (PICU).
Objective: To determine the frequency of adverse events associated with immediate tracheal intubation in children (1-18 years) from Pediatric Intensive Care Unit of Tertiary Care H...
Mechanical seal friction condition monitoring based on bispectral characteristics
Mechanical seal friction condition monitoring based on bispectral characteristics
Purpose
The purpose of this paper is to investigate the monitoring of the friction condition of mechanical seals.
Design/methodology/approach
Acoustic emission signals from the f...


