Quantitative and Qualitative Comparison of Low-Temperature, Heat-Activated Cooling Systems
View through CrossRef
This paper compares the quantitative and qualitative performances of three different heat-activated cooling systems, e.g. a silica-gel water adsorption system, a LiBr-H2O absorption system, and a desiccant air system. Each of these systems can be utilized at relatively low heat source temperatures, but it is unclear which of these systems is best suited to what range of heat source temperature. Our study explores answers to this question by generating quantitative results comparing their relative thermal performance, i.e. COP and refrigeration capacity, and a qualitative comparison based on the size, maturity of technology, safe operation, etc. Each of these systems is assumed to work under the following operating conditions: a condensing temperature of 29 °C, an evaporating temperature of 19 °C, a hot water temperature range of 40-120 °C, and a hot water mass flow rate of 0.4 kg/sec. Individual mathematical models are developed for each system and numerically solved using different techniques. In order to provide a fair comparison between the fundamentally different systems, a UA (overall heat transfer coefficient multiplied by the heat transfer area) value of 1.0 kW/ °C is considered for the heat exchanger that transfers heat from the supplied hot water. Furthermore, to compare systems of similar size, the mass of silica gel in adsorption and desiccant system and mass of LiBr-H2O solution in absorption system were specified such that each system provides the same amount of refrigeration (8.0 kW) at a source temperature of 90 °C. It is found that the absorption and adsorption cooling systems have a higher refrigeration capacity at heat source temperatures below 90 °C, while the desiccant air system outperforms the others at temperatures above 90 °C.
Title: Quantitative and Qualitative Comparison of Low-Temperature, Heat-Activated Cooling Systems
Description:
This paper compares the quantitative and qualitative performances of three different heat-activated cooling systems, e.
g.
a silica-gel water adsorption system, a LiBr-H2O absorption system, and a desiccant air system.
Each of these systems can be utilized at relatively low heat source temperatures, but it is unclear which of these systems is best suited to what range of heat source temperature.
Our study explores answers to this question by generating quantitative results comparing their relative thermal performance, i.
e.
COP and refrigeration capacity, and a qualitative comparison based on the size, maturity of technology, safe operation, etc.
Each of these systems is assumed to work under the following operating conditions: a condensing temperature of 29 °C, an evaporating temperature of 19 °C, a hot water temperature range of 40-120 °C, and a hot water mass flow rate of 0.
4 kg/sec.
Individual mathematical models are developed for each system and numerically solved using different techniques.
In order to provide a fair comparison between the fundamentally different systems, a UA (overall heat transfer coefficient multiplied by the heat transfer area) value of 1.
0 kW/ °C is considered for the heat exchanger that transfers heat from the supplied hot water.
Furthermore, to compare systems of similar size, the mass of silica gel in adsorption and desiccant system and mass of LiBr-H2O solution in absorption system were specified such that each system provides the same amount of refrigeration (8.
0 kW) at a source temperature of 90 °C.
It is found that the absorption and adsorption cooling systems have a higher refrigeration capacity at heat source temperatures below 90 °C, while the desiccant air system outperforms the others at temperatures above 90 °C.
Related Results
Film Cooling Calculations With an Iterative Conjugate Heat Transfer Approach Using Empirical Heat Transfer Coefficient Corrections
Film Cooling Calculations With an Iterative Conjugate Heat Transfer Approach Using Empirical Heat Transfer Coefficient Corrections
An iterative conjugate heat transfer technique has been developed to predict the temperatures on film cooled surfaces such as flat plates and turbine blades. Conventional approache...
Investigation of the Influence of Wetting Ability of the Sprayed Surface of the Heat Exchanger on the Process of Evaporative Cooling
Investigation of the Influence of Wetting Ability of the Sprayed Surface of the Heat Exchanger on the Process of Evaporative Cooling
Ensuring the required microclimate parameters is the most critical task in hot climates. In pig farms, air cooling is provided by means of steam-compression chillers or evaporative...
Effect of ocean heat flux on Titan's topography and tectonic stresses
Effect of ocean heat flux on Titan's topography and tectonic stresses
INTRODUCTIONThe thermo-mechanical evolution of Titan's ice shell is primarily controlled by the mode of the heat transfer in the ice shell and the amount of heat coming from the oc...
A study to assess the energy savings potential in the ocean going trawler 'Roxana Bank'
A study to assess the energy savings potential in the ocean going trawler 'Roxana Bank'
Increasing fuel prices have forced marine engineers and diesel engine manufacturers to look at methods of. reducing fuel consumption without a loss in output power. Engineers are a...
Enhancement of Film Cooling Effectiveness Using Dean Vortices
Enhancement of Film Cooling Effectiveness Using Dean Vortices
Abstract
Film cooling technology is widely used in gas turbines. Improvement of gas turbine thermal efficiency, specific power and specific thrust can be achieved by...
Simulation and Economic Research of Circulating Cooling Water Waste Heat and Water Resource Recovery System
Simulation and Economic Research of Circulating Cooling Water Waste Heat and Water Resource Recovery System
Industrial circulating cooling water contains a large amount of low-quality energy, which is lost to the environment through cooling towers. It is of great significance and potenti...
Thermal energy storage with tunnels in different subsurface conditions
Thermal energy storage with tunnels in different subsurface conditions
The widespread use of the underground and global climate change impact the urban subsurface temperature. Changes in the subsurface environment can affect the performance of undergr...
Impingement/Effusion Cooling With Low Coolant Mass Flow
Impingement/Effusion Cooling With Low Coolant Mass Flow
A low coolant mass flow impingement/effusion design for a low NOx combustor wall cooling application was predicted, using conjugate heat transfer (CHT) computational fluid dynamics...