Redesigned Chuck Table: Deep-grooved Chuck Table for Higher Vacuum Suction of Singulated Package
View through CrossRef
Singulation machine frequently encounters Z-Picker errors and occasionally, worst case of unit scattering which leads on the gross unit rejection and scrappage. As analyzed, shifted units found on the chuck table module upon singulation of strip. Shifted units were induced on the last 3 cut lines when the units were dragged by the blade as the area held by chuck table vacuum suction gets smaller. These shifted units caused misalignment on the next singulation modules to the turn table module and Z-Picker module that resulted to vacuum loss. With the situation at hand, the authors have assessed the current design of the chuck table. The authors have found out that chuck table have shallow-grooved rubber jig pockets that flatten upon suction of units resulted to lesser area for vacuum application. As referenced to the formula F=PA, larger area multiplied by suction pressure results to better force to hold the units, thus redesigned chuck table with deep groove was introduced. The study also pertains to the analysis and validation on the application of deep-grooved rubber jig pockets of chuck table aiming to solve the unit shifting during sawing. Elimination of unit shifting was validated to be effective upon application of the deep-grooved chuck table. The study and validation of redesigned chuck table is essential to avoid unit scattering and unit missing.
Sciencedomain International
Title: Redesigned Chuck Table: Deep-grooved Chuck Table for Higher Vacuum Suction of Singulated Package
Description:
Singulation machine frequently encounters Z-Picker errors and occasionally, worst case of unit scattering which leads on the gross unit rejection and scrappage.
As analyzed, shifted units found on the chuck table module upon singulation of strip.
Shifted units were induced on the last 3 cut lines when the units were dragged by the blade as the area held by chuck table vacuum suction gets smaller.
These shifted units caused misalignment on the next singulation modules to the turn table module and Z-Picker module that resulted to vacuum loss.
With the situation at hand, the authors have assessed the current design of the chuck table.
The authors have found out that chuck table have shallow-grooved rubber jig pockets that flatten upon suction of units resulted to lesser area for vacuum application.
As referenced to the formula F=PA, larger area multiplied by suction pressure results to better force to hold the units, thus redesigned chuck table with deep groove was introduced.
The study also pertains to the analysis and validation on the application of deep-grooved rubber jig pockets of chuck table aiming to solve the unit shifting during sawing.
Elimination of unit shifting was validated to be effective upon application of the deep-grooved chuck table.
The study and validation of redesigned chuck table is essential to avoid unit scattering and unit missing.
Related Results
Hemolytic characteristics of three suctioning systems for use with a newly developed cardiopulmonary bypass system
Hemolytic characteristics of three suctioning systems for use with a newly developed cardiopulmonary bypass system
Introduction: We have been developing a closed-circuit cardiopulmonary bypass (CPB) system (“Dihead CPB”) for application during coronary artery bypass grafting (CABG) and valve su...
Suction Pile Allowable Suction Pressure Envelopes Based on Soil Failure and Structural Buckling
Suction Pile Allowable Suction Pressure Envelopes Based on Soil Failure and Structural Buckling
Abstract
This study develops the allowable suction pressure envelopes using applicable industrial codes for different suction pile sizes at various penetration depth...
Development of Normal‐Suction Boundary Control Method Based on Inflow Cannula Pressure Waveform for the Undulation Pump Ventricular Assist Device
Development of Normal‐Suction Boundary Control Method Based on Inflow Cannula Pressure Waveform for the Undulation Pump Ventricular Assist Device
AbstractIt is desirable to obtain the maximum assist without suction in ventricular assist devices (VADs). However, high driving power of a VAD may cause severe ventricle suction t...
Stratigraphic studies of Ganymede’s tectonic activity in the bright terrain: results from the Byblus Sulcus and Harpagia Sulcus regions
Stratigraphic studies of Ganymede’s tectonic activity in the bright terrain: results from the Byblus Sulcus and Harpagia Sulcus regions
The Jovian satellite Ganymede experienced a pronounced period of tectonic resurfacing forming the extended bright or light terrain the so-called Sulci, which cover about 2/3 of Gan...
Modification of a Radial Pump Characteristics With Fluid Suction in the Vaneless Space
Modification of a Radial Pump Characteristics With Fluid Suction in the Vaneless Space
Abstract
Flow instability is a common unsteady phenomenon in the field of turbomachinery that often causes large pressure fluctuations, performance penalties, and st...
A Cluster Randomized Controlled Trial of the Dental Sealants Quality in Rural Schoolchildren Using Innovative Suction without Dental Assistance
A Cluster Randomized Controlled Trial of the Dental Sealants Quality in Rural Schoolchildren Using Innovative Suction without Dental Assistance
This study examined whether the moisture control innovation (tongue and cheek retractors and saliva contamination (SS-suction)) used without dental assistance could improve the qua...
Die-Level Vacuum Packaging of Mems Devices with Non-Evaporating Getters
Die-Level Vacuum Packaging of Mems Devices with Non-Evaporating Getters
In this article original method of vacuum packaging in ceramic package 5142.48-A with non-evaporating getter inside is described. Some MEMS devices such as gyroscopes, acceleromete...
The clinical efficacy of novel vacuum suction ureteroscopic lithotripsy in the treatment of upper ureteral calculi
The clinical efficacy of novel vacuum suction ureteroscopic lithotripsy in the treatment of upper ureteral calculi
Abstract
This study investigated the clinical efficacy of a novel vacuum suction ureteroscopic approach in the treatment of upper ureteral calculi. A total of 160 patients ...