Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Development of Normal‐Suction Boundary Control Method Based on Inflow Cannula Pressure Waveform for the Undulation Pump Ventricular Assist Device

View through CrossRef
AbstractIt is desirable to obtain the maximum assist without suction in ventricular assist devices (VADs). However, high driving power of a VAD may cause severe ventricle suction that can induce arrhythmia, hemolysis, and pump damage. In this report, an appropriate VAD driving level that maximizes the assist effect without severe systolic suction was explored. The target driving level was set at the boundary between low driving power without suction and high driving power with frequent suction. In the boundary range, intermittent mild suction may occur. Driving power was regulated by the suction occurrence. The normal‐suction boundary control method was evaluated in a female goat implanted with an undulation pump ventricular assist device (UPVAD). The UPVAD was driven in a semipulsatile mode with heartbeat synchronization control. Systolic driving power was adjusted using a normal‐suction boundary control method developed for this study. We confirmed that driving power could be maintained in the boundary range. Occurrences of suction were evaluated using the suction ratio. We defined this ratio as the number of suction occurrences divided by the number of heartbeats. The suction ratio decreased by 70% when the normal‐suction boundary control method was used.
Title: Development of Normal‐Suction Boundary Control Method Based on Inflow Cannula Pressure Waveform for the Undulation Pump Ventricular Assist Device
Description:
AbstractIt is desirable to obtain the maximum assist without suction in ventricular assist devices (VADs).
However, high driving power of a VAD may cause severe ventricle suction that can induce arrhythmia, hemolysis, and pump damage.
In this report, an appropriate VAD driving level that maximizes the assist effect without severe systolic suction was explored.
The target driving level was set at the boundary between low driving power without suction and high driving power with frequent suction.
In the boundary range, intermittent mild suction may occur.
Driving power was regulated by the suction occurrence.
The normal‐suction boundary control method was evaluated in a female goat implanted with an undulation pump ventricular assist device (UPVAD).
The UPVAD was driven in a semipulsatile mode with heartbeat synchronization control.
Systolic driving power was adjusted using a normal‐suction boundary control method developed for this study.
We confirmed that driving power could be maintained in the boundary range.
Occurrences of suction were evaluated using the suction ratio.
We defined this ratio as the number of suction occurrences divided by the number of heartbeats.
The suction ratio decreased by 70% when the normal‐suction boundary control method was used.

Related Results

Effectiveness of Protocol Based Nursing Care of Patients with Intravenous Line Cannula in Selected Hospital at Ambala City
Effectiveness of Protocol Based Nursing Care of Patients with Intravenous Line Cannula in Selected Hospital at Ambala City
Health team members are always bound to be right for the betterment of patient, but when it becomes difficult to keep up there comes the need for a guidance to lead them on the rig...
Modification of a Radial Pump Characteristics With Fluid Suction in the Vaneless Space
Modification of a Radial Pump Characteristics With Fluid Suction in the Vaneless Space
Abstract Flow instability is a common unsteady phenomenon in the field of turbomachinery that often causes large pressure fluctuations, performance penalties, and st...
The Effects of Periodic Suction on Separated Flow in Diffuser
The Effects of Periodic Suction on Separated Flow in Diffuser
The effects of periodic suction on the separated flow are still unclear and the relevant researches are still scarce, thus this paper presents a periodic suction method to suppress...
Suction Pile Allowable Suction Pressure Envelopes Based on Soil Failure and Structural Buckling
Suction Pile Allowable Suction Pressure Envelopes Based on Soil Failure and Structural Buckling
Abstract This study develops the allowable suction pressure envelopes using applicable industrial codes for different suction pile sizes at various penetration depth...
Effect of Suction Side Jet on the Shock Wave Boundary Layer Interaction in Transonic Turbine
Effect of Suction Side Jet on the Shock Wave Boundary Layer Interaction in Transonic Turbine
Abstract In this paper, the effect of round jet with inclination angle 135° upstream the throat on the suction surface on shock wave boundary-layer interaction was i...
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
<span style="font-size:11pt"><span style="background:#f9f9f4"><span style="line-height:normal"><span style="font-family:Calibri,sans-serif"><b><spa...
Impact of Cannula Size on Clinical Outcomes in Peripheral Venoarterial Extracorporeal Membrane Oxygenation
Impact of Cannula Size on Clinical Outcomes in Peripheral Venoarterial Extracorporeal Membrane Oxygenation
Venoarterial extracorporeal membrane oxygenation (VA ECMO) is an effective mechanical circulatory support for cardiopulmonary failure. Conventionally, an arterial cannula over 15 F...

Back to Top