Allograft Structural Interbody Spacers Compared to PEEK Cages in Cervical Fusion: Benchtop and Clinical Evidence
View through CrossRef
Cervical degenerative disc disease (CDDD) can lead to radiculopathy and myelopathy, resulting in pain, lack of function, and immobility. Anterior cervical discectomy and fusion (ACDF) is a common surgical treatment modality for advanced CDDD. ACDF involves removal of the affected disc(s) followed by replacement with a bone or synthetic graft. Historically, autograft has been considered the gold standard for interbody fusion. However, it is often associated with limitations, including donor site morbidity and limited quality and supply, prompting surgeons to seek alternatives. Two of the most common alternatives are structural bone allografts and polyetheretherketone (PEEK) synthetic cages. Both, advantageously, have similar mechanical properties to autologous bone, with comparable elastic modulus values. However, a lack of osseointegration of PEEK cages has been reported both pre-clinically and clinically. Reported fusion rates assessed radiographically are higher with the use of structural bone allografts compared to PEEK cages, while having a lower incidence of pseudarthrosis. This book chapter will discuss in detail the pre-clinical and clinical performance of structural allografts in comparison to conventional PEEK cages.
Title: Allograft Structural Interbody Spacers Compared to PEEK Cages in Cervical Fusion: Benchtop and Clinical Evidence
Description:
Cervical degenerative disc disease (CDDD) can lead to radiculopathy and myelopathy, resulting in pain, lack of function, and immobility.
Anterior cervical discectomy and fusion (ACDF) is a common surgical treatment modality for advanced CDDD.
ACDF involves removal of the affected disc(s) followed by replacement with a bone or synthetic graft.
Historically, autograft has been considered the gold standard for interbody fusion.
However, it is often associated with limitations, including donor site morbidity and limited quality and supply, prompting surgeons to seek alternatives.
Two of the most common alternatives are structural bone allografts and polyetheretherketone (PEEK) synthetic cages.
Both, advantageously, have similar mechanical properties to autologous bone, with comparable elastic modulus values.
However, a lack of osseointegration of PEEK cages has been reported both pre-clinically and clinically.
Reported fusion rates assessed radiographically are higher with the use of structural bone allografts compared to PEEK cages, while having a lower incidence of pseudarthrosis.
This book chapter will discuss in detail the pre-clinical and clinical performance of structural allografts in comparison to conventional PEEK cages.
Related Results
Determinants of lateral fusion in single-level oblique lateral lumbar interbody fusion: a retrospective analysis of fusion patterns and clinical outcomes
Determinants of lateral fusion in single-level oblique lateral lumbar interbody fusion: a retrospective analysis of fusion patterns and clinical outcomes
Study Design: Retrospective cohort study.Purpose: This study aimed to (1) determine the incidence of lateral fusion following single-level oblique lateral interbody fusion (OLIF); ...
Biomechanical Analysis of Pullout Strengths of Rotator Cuff and Glenoid Anchors: 2011 Update
Biomechanical Analysis of Pullout Strengths of Rotator Cuff and Glenoid Anchors: 2011 Update
Purpose
To evaluate the biomechanical and design characteristics of newer suture anchors.
Methods
...
Comparison and analysis of measurements for crystallinity of PEEK and CF/PEEK composites
Comparison and analysis of measurements for crystallinity of PEEK and CF/PEEK composites
AbstractPEEK and CF/PEEK are two significant materials whose properties are intricately linked to their crystallization behavior. This study employed three analytical techniques—de...
Study on microstructures and mechanical performance of laser transmission welding of poly-ether-ether-ketone (PEEK) and carbon fiber reinforced PEEK (CFR-PEEK)
Study on microstructures and mechanical performance of laser transmission welding of poly-ether-ether-ketone (PEEK) and carbon fiber reinforced PEEK (CFR-PEEK)
The reliable assembly of poly-ether-ether-ketone (PEEK) and carbon fiber-reinforced PEEK (CFR-PEEK) is crucial to effective load transfer within lightweight and high-stiffness stru...
NS13P
A PROSPECTIVE COMPARISON OF TWO CERVICAL INTERBODY FUSION CAGES
NS13P
A PROSPECTIVE COMPARISON OF TWO CERVICAL INTERBODY FUSION CAGES
Purpose For some time the surgical management of chronic back pain has utilised interbody lumbar cages. Recently interbody cages for use in the cervical spine have been produced. ...
In vitro physicochemical and biological properties of titanium alloy, zirconia, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone
In vitro physicochemical and biological properties of titanium alloy, zirconia, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone
Implant repair is a common means to restore the normal function of the hard tissues (bone or teeth). At present, the commonly and potentially used implant materials include titaniu...
The Nuclear Fusion Award
The Nuclear Fusion Award
The Nuclear Fusion Award ceremony for 2009 and 2010 award winners was held during the 23rd IAEA Fusion Energy Conference in Daejeon. This time, both 2009 and 2010 award winners w...
Análisis de fatiga y flexión sobre implantes monoblock de PEEK y la unión pilar PEEK-implante de titanio
Análisis de fatiga y flexión sobre implantes monoblock de PEEK y la unión pilar PEEK-implante de titanio
En este trabajo de tesis doctoral se analizaron las fuerzas de flexión y fatiga sobre implantes dentales monoblock de PEEK y también la unión pilar PEEK - implante de titanio es un...