Indirect temperature protection of an asynchronous generator by stator winding resistance measurement with superimposition of high-frequency pulse signals

View through CrossRef
The article deals with the indirect methods for calculating the temperature of asynchronous generators with the introduction of a pulse component in the power supply circuit of the stator windings of asynchronous generators with squirrel-cage rotor. The relevance of this issue is determined by the need to improve asynchronous energy converters to increase their reliability and safety. The object of the study is an asynchronous generator with squirrel-cage rotor, which consume 40 % of the total electricity generated, and are the most affordable. One of the dangerous modes of asynchronous generators is their overheating as a result of increased currents and temperatures. The thermal protection of the stator winding of asynchronous generators relies primarily on measuring or determining the winding temperature. An indirect method for determining temperature based on measuring the resistance of the stator of an asynchronous generator with squirrel-cage rotor is proposed. The method is based on superimposing pulse signals of small amplitude and high frequency of 600 Hz on an alternating sinusoidal voltage with a frequency of 50 Hz. A simulation model for a 3 kW asynchronous generator has been developed. There were given the simulation results. The estimated values of the active resistances of the stator can be used to indirectly determine the temperature of the windings in thermal protection devices of asynchronous generators, as well as for control, monitoring and diagnostics of the technical condition. The research results confirm the possibility of indirect temperature determination and the creation of a thermal protection system for asynchronous energy converters based on the use of estimation methods.
Title: Indirect temperature protection of an asynchronous generator by stator winding resistance measurement with superimposition of high-frequency pulse signals
Description:
The article deals with the indirect methods for calculating the temperature of asynchronous generators with the introduction of a pulse component in the power supply circuit of the stator windings of asynchronous generators with squirrel-cage rotor.
The relevance of this issue is determined by the need to improve asynchronous energy converters to increase their reliability and safety.
The object of the study is an asynchronous generator with squirrel-cage rotor, which consume 40 % of the total electricity generated, and are the most affordable.
One of the dangerous modes of asynchronous generators is their overheating as a result of increased currents and temperatures.
The thermal protection of the stator winding of asynchronous generators relies primarily on measuring or determining the winding temperature.
An indirect method for determining temperature based on measuring the resistance of the stator of an asynchronous generator with squirrel-cage rotor is proposed.
The method is based on superimposing pulse signals of small amplitude and high frequency of 600 Hz on an alternating sinusoidal voltage with a frequency of 50 Hz.
A simulation model for a 3 kW asynchronous generator has been developed.
There were given the simulation results.
The estimated values of the active resistances of the stator can be used to indirectly determine the temperature of the windings in thermal protection devices of asynchronous generators, as well as for control, monitoring and diagnostics of the technical condition.
The research results confirm the possibility of indirect temperature determination and the creation of a thermal protection system for asynchronous energy converters based on the use of estimation methods.

Related Results

Measurement and Simulation of Hydro-Generator’s Asynchronous Operation
Measurement and Simulation of Hydro-Generator’s Asynchronous Operation
The extended testing of hydro-generator with Pelton turbine (rated 35 MVA) was performed on a generator whose lifespan expired and it was going to be replaced. This was the perfect...
Transformer Winding Deformation Detection and Modeling Based on Frequency Response Method
Transformer Winding Deformation Detection and Modeling Based on Frequency Response Method
Power transformer is one of the key equipment of the power system, and its reliable operation is an important factor for the safety of the whole power grid and even national power....
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract Introduction Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
A calculation method of winding loss of high frequency transformer based on finite element method
A calculation method of winding loss of high frequency transformer based on finite element method
In this paper, a winding loss calculation method used in the field of converter transformers is introduced into the realm of high-frequency transformers for the first time. In addi...
Research on Fuzzy Control Based Flexible Composite Winding System
Research on Fuzzy Control Based Flexible Composite Winding System
In the process of composite resin prepreg tape winding, the presence of pores or voids among the layers of composite can result in reduced strength of winding. To alleviate this pr...
Analisis Concentrated Winding Menggunakan Metode Clockwise dan Kombinasi pada PMSG 12S8P
Analisis Concentrated Winding Menggunakan Metode Clockwise dan Kombinasi pada PMSG 12S8P
Kebutuhan akan energi listrik terus meningkat seiring dengan bertambahnya jumlah penduduk dan kemajuan teknologi, meningkatnya kebutuhan energi listrik harus diiringi dengan mening...
Fabrication and Characterization of Floating Small Hydroelectric Power Generator using Spiral Water Wheel
Fabrication and Characterization of Floating Small Hydroelectric Power Generator using Spiral Water Wheel
For the practical application of small hydroelectric power generation, the authors designed a floating small hydroelectric power generation system equipped with a float, and fabric...
Analisa Pengaruh Tegangan Harmonik Terhadap Regulasi Tegangan Eksitasi Generator Satu Fasa
Analisa Pengaruh Tegangan Harmonik Terhadap Regulasi Tegangan Eksitasi Generator Satu Fasa
Esensinya setiap generator listrik satu fasa maupun tiga fasa telah dilengkapi dengan sistem eksitasi. Sistem eksitasi generator ada tiga, yaitu sistem eksitasi statis, dinamis, da...

Back to Top