SU‐GG‐T‐183: Enhanced Accuracy of IMRT Photon Fluence Profile Surveillance: Iterative Resolution Correction of the DAVID Chamber
View through CrossRef
Purpose: The DAVID system (PTW‐Freiburg, Germany) is a multiwire ionization chamber placed in the accessory holder, capable of continuously monitoring treatment delivery. The system supplements the pre‐treatment dosimetric plan verification for advanced radiotherapy techniques such as IMRT and rotational therapy. Each detection wire signal is associated to the opening width of the MLC leaf pair it is surveying. The blurring of the lateral transport of secondary electrons within the chamber is corrected by an iterative deconvolution algorithm hence achieving enhanced error detection efficiency. Method and Materials: The measured signal profile S(x) is regarded as the result of a convolution of the true photon fluence profile P(x) with the lateral response function fξ(x) (ξ = sequential number of a wire). The fξ(x) was measured for each detection wire by opening only the MLC leaf pair it is associated with. The iterative algorithm consists in a sequence of approximations for Pn(x) which quickly converges towards the desired true P(x). Each Pn(x) is numerically convolved with fξ(x) and from the comparison of the result with S(x), the next approximation Pn+1(x) is derived. Results: The fine structure of the fluence profile is restored through the deconvolution. The lateral resolution of the DAVID system has been improved and error detection efficiency of the DAVID system can be enhanced by a factor of 2. The deconvolution of each IMRT segment can be performed in less than 1 sec. Conclusion: The developed iterative deconvolution method is capable of correcting for the blurring of the DAVID chamber signal profiles due to the lateral transport of scattered electrons within the chamber. The short computational time needed makes the algorithm feasible to be implemented in the daily routine to gain an increased specificity in IMRT photon fluence profile surveillance.
Title: SU‐GG‐T‐183: Enhanced Accuracy of IMRT Photon Fluence Profile Surveillance: Iterative Resolution Correction of the DAVID Chamber
Description:
Purpose: The DAVID system (PTW‐Freiburg, Germany) is a multiwire ionization chamber placed in the accessory holder, capable of continuously monitoring treatment delivery.
The system supplements the pre‐treatment dosimetric plan verification for advanced radiotherapy techniques such as IMRT and rotational therapy.
Each detection wire signal is associated to the opening width of the MLC leaf pair it is surveying.
The blurring of the lateral transport of secondary electrons within the chamber is corrected by an iterative deconvolution algorithm hence achieving enhanced error detection efficiency.
Method and Materials: The measured signal profile S(x) is regarded as the result of a convolution of the true photon fluence profile P(x) with the lateral response function fξ(x) (ξ = sequential number of a wire).
The fξ(x) was measured for each detection wire by opening only the MLC leaf pair it is associated with.
The iterative algorithm consists in a sequence of approximations for Pn(x) which quickly converges towards the desired true P(x).
Each Pn(x) is numerically convolved with fξ(x) and from the comparison of the result with S(x), the next approximation Pn+1(x) is derived.
Results: The fine structure of the fluence profile is restored through the deconvolution.
The lateral resolution of the DAVID system has been improved and error detection efficiency of the DAVID system can be enhanced by a factor of 2.
The deconvolution of each IMRT segment can be performed in less than 1 sec.
Conclusion: The developed iterative deconvolution method is capable of correcting for the blurring of the DAVID chamber signal profiles due to the lateral transport of scattered electrons within the chamber.
The short computational time needed makes the algorithm feasible to be implemented in the daily routine to gain an increased specificity in IMRT photon fluence profile surveillance.
Related Results
SU‐GG‐T‐149: 4D IMRT Quality Assurance (QA) by Dynamic Log File Analysis
SU‐GG‐T‐149: 4D IMRT Quality Assurance (QA) by Dynamic Log File Analysis
Purpose: 4D IMRT was a technique developed to account for dosimetry errors from intra‐fraction motion, especially from anatomy transformation caused by respiration. To perform 4D I...
Riverine water chemistry and rock weathering processes of Qingyi River basin, a subtropical basin in east China
Riverine water chemistry and rock weathering processes of Qingyi River basin, a subtropical basin in east China
To investigate the rock weathering processes in silicate-dominated subtropical basin in east China, we analyzed major ion compositions of rivers and precipitation samples in the Qi...
What is an acceptably smoothed fluence? Dosimetric and delivery considerations for dynamic sliding window IMRT
What is an acceptably smoothed fluence? Dosimetric and delivery considerations for dynamic sliding window IMRT
Abstract
Background
The study summarised in this report aimed to investigate the interplay between fluence complexity, dose calculation algorithm...
Shadow and photon ring of black hole in asymptotically safe gravity
Shadow and photon ring of black hole in asymptotically safe gravity
In this paper, we focus on discussing the influence of thin disk accretion and asymptotically safe (AS) gravity correction parameter on the shadow and photon ring of black holes. F...
SU‐E‐T‐439: Implementation of an Iterative Deconvolution Method in a Daily In‐Vivo Verification Procedure with the DAVID System
SU‐E‐T‐439: Implementation of an Iterative Deconvolution Method in a Daily In‐Vivo Verification Procedure with the DAVID System
Purpose: The DAVID system (PTW‐Freiburg, Germany) is a multiwire ionization chamber placed in the accessory holder, capable of continuously monitoring treatment deliveries such as ...
Dosimetric comparisons of intensity‐modulated radiation therapy and three‐dimensional conformal radiation therapy for left‐sided breast cancer after radical surgery
Dosimetric comparisons of intensity‐modulated radiation therapy and three‐dimensional conformal radiation therapy for left‐sided breast cancer after radical surgery
AbstractObjectivePostoperative radiotherapy for breast cancer is an effective way to control tumor recurrence; however, there are advantages and disadvantages to different radiothe...
The photon blockade effect of a complete Buck-Sukumar model
The photon blockade effect of a complete Buck-Sukumar model
The Buck-Sukumar (BS) model, with a nonlinear coupling between the atom and the light field, is well defined only when its coupling strength is lower than a critical coupling. Its ...
XIII Congresso da Sociedade Brasileira de Radioterapia (SBRT); II Encontro de Residentes em Radioterapia da SBRT; XI Jornada de Física Médica; IX Encontro de Enfermeiros Oncologistas em Radioterapia; VIII Encontro de Técnicos em Radioterapia
XIII Congresso da Sociedade Brasileira de Radioterapia (SBRT); II Encontro de Residentes em Radioterapia da SBRT; XI Jornada de Física Médica; IX Encontro de Enfermeiros Oncologistas em Radioterapia; VIII Encontro de Técnicos em Radioterapia
Resumos escolhidos para publicação. Nessa edição, os títulos foram: Níveis de Selênio Plasmático antes e após Radioterapia no Câncer de Próstata; Avaliação Digital de Imagens Derma...