Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A nonlinear scaling‐based normalized metal artifact reduction to reduce low‐frequency artifacts in energy‐integrating and photon‐counting CT

View through CrossRef
AbstractBackgroundMetal within the scan plane can cause severe artifacts when reconstructing X‐ray computed tomography (CT) scans. Both in clinical use and recent research, normalized metal artifact reduction (NMAR) has established as the reference method for correcting metal artifacts, but NMAR introduces inconsistencies within the sinogram, which can cause additional low‐frequency artifacts after image reconstruction.PurposeThis paper introduces an extension to NMAR by applying a nonlinear scaling function (NLS‐NMAR) to reduce low‐frequency artifacts, which get introduced by the reconstruction of interpolation‐edge‐related sinogram inconsistencies in the normalized sinogram domain.MethodsAfter linear interpolation of the metal trace, an NLS function is applied in the prior‐normalized sinogram domain to reduce the impact of the interpolation edges during filtered backprojection. After sinogram denormalization and image reconstruction, the low frequencies of the NLS image are combined with different high frequencies to restore anatomic details. An anthropomorphic dental phantom with removable metal inserts was utilized on two different CT systems to quantitatively assess the artifact reduction performance in terms of HU deviations and the root‐mean‐square‐error within relevant regions of interest. Clinical dental examples were assessed to qualitatively demonstrate the problem of the interpolation‐related blooming as well as to demonstrate the performance of the NLS function to reduce respective artifacts. To quantitatively prove HU consistency, HU values were assessed in central ROIs in the clinical cases. In addition, single clinical cases of a hip replacement and pedicle screws in the spine are shown to demonstrate the method's results in other body regions.ResultsThe NLS‐NMAR can minimize the effect of interpolation‐related sinogram inconsistencies and thus reduce resulting hyperdense blooming artifacts. In the phantom results, the reconstructions with the NLS‐NMAR‐corrected low frequencies demonstrate the lowest error. In the qualitative assessment of the clinical data, the NLS‐NMAR shows a tremendous enhancement in image quality, also performing best within all assessed images series.ConclusionThe NLS‐NMAR provides a small yet effective extension to conventional NMAR by reducing low‐frequency hyperdense metal trace‐interpolation‐related artifacts in computed tomography.
Title: A nonlinear scaling‐based normalized metal artifact reduction to reduce low‐frequency artifacts in energy‐integrating and photon‐counting CT
Description:
AbstractBackgroundMetal within the scan plane can cause severe artifacts when reconstructing X‐ray computed tomography (CT) scans.
Both in clinical use and recent research, normalized metal artifact reduction (NMAR) has established as the reference method for correcting metal artifacts, but NMAR introduces inconsistencies within the sinogram, which can cause additional low‐frequency artifacts after image reconstruction.
PurposeThis paper introduces an extension to NMAR by applying a nonlinear scaling function (NLS‐NMAR) to reduce low‐frequency artifacts, which get introduced by the reconstruction of interpolation‐edge‐related sinogram inconsistencies in the normalized sinogram domain.
MethodsAfter linear interpolation of the metal trace, an NLS function is applied in the prior‐normalized sinogram domain to reduce the impact of the interpolation edges during filtered backprojection.
After sinogram denormalization and image reconstruction, the low frequencies of the NLS image are combined with different high frequencies to restore anatomic details.
An anthropomorphic dental phantom with removable metal inserts was utilized on two different CT systems to quantitatively assess the artifact reduction performance in terms of HU deviations and the root‐mean‐square‐error within relevant regions of interest.
Clinical dental examples were assessed to qualitatively demonstrate the problem of the interpolation‐related blooming as well as to demonstrate the performance of the NLS function to reduce respective artifacts.
To quantitatively prove HU consistency, HU values were assessed in central ROIs in the clinical cases.
In addition, single clinical cases of a hip replacement and pedicle screws in the spine are shown to demonstrate the method's results in other body regions.
ResultsThe NLS‐NMAR can minimize the effect of interpolation‐related sinogram inconsistencies and thus reduce resulting hyperdense blooming artifacts.
In the phantom results, the reconstructions with the NLS‐NMAR‐corrected low frequencies demonstrate the lowest error.
In the qualitative assessment of the clinical data, the NLS‐NMAR shows a tremendous enhancement in image quality, also performing best within all assessed images series.
ConclusionThe NLS‐NMAR provides a small yet effective extension to conventional NMAR by reducing low‐frequency hyperdense metal trace‐interpolation‐related artifacts in computed tomography.

Related Results

The photon blockade effect of a complete Buck-Sukumar model
The photon blockade effect of a complete Buck-Sukumar model
The Buck-Sukumar (BS) model, with a nonlinear coupling between the atom and the light field, is well defined only when its coupling strength is lower than a critical coupling. Its ...
CT Metal Artifact Reduction based on Virtual Generated Artifacts Using Modified pix2pix
CT Metal Artifact Reduction based on Virtual Generated Artifacts Using Modified pix2pix
Abstract Background: Metal artifacts introduce challenges in image-guided diagnosis or accurate dose calculations. This study aims to reduce metal artifacts from the spinal...
Nonlinearly scaled prior image‐controlled frequency split for high‐frequency metal artifact reduction in computed tomography
Nonlinearly scaled prior image‐controlled frequency split for high‐frequency metal artifact reduction in computed tomography
AbstractPurposeThis paper introduces a new approach for the dedicated reduction of high‐frequency metal artifacts, which applies a nonlinear scaling (NLS) transfer function on the ...
Dosimetric impact of metal artifact reduction for spinal implants in stereotactic body radiotherapy
Dosimetric impact of metal artifact reduction for spinal implants in stereotactic body radiotherapy
Abstract Background Metal artifacts due to spinal implants can affect the accuracy of dose calculation for radiotherapy. However, the dosimetric impact of metal artifact r...
A New Iterative Metal Artifact Reduction Algorithm for Both Energy-Integrating and Photon-Counting CT Systems
A New Iterative Metal Artifact Reduction Algorithm for Both Energy-Integrating and Photon-Counting CT Systems
Objectives The aim of this study was to introduce and evaluate a new metal artifact reduction framework (iMARv2) that addresses the drawbacks (residual artifacts after ...
Perturbed solution and analyses for single photon transmission equation in optical fiber
Perturbed solution and analyses for single photon transmission equation in optical fiber
As is well known, quantum optics has developed significantly in recent years and advanced several hot research topics, such as quantum communications, quantum sensing, quantum calc...
Shadow and photon ring of black hole in asymptotically safe gravity
Shadow and photon ring of black hole in asymptotically safe gravity
In this paper, we focus on discussing the influence of thin disk accretion and asymptotically safe (AS) gravity correction parameter on the shadow and photon ring of black holes. F...
Increasing familiarity with the heartbeat counting task does not affect performance
Increasing familiarity with the heartbeat counting task does not affect performance
Background: Interoception is typically defined as the processing and perception of internal signals. A common evaluation of interoceptive abilities is via the perception of heartbe...

Back to Top